A comparative analysis of constant impedance and constant power loads in a distribution network

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 6 (2024)

DOI
10.11591/ijece.v14i6.pp6111-6121
ISSN
2722-2578, 2088-8708
Published
2024-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Most conventional power systems adopt radial distribution network wherein multiple loads are connected across the distribution transformer. As the number of loads increases, it results in poor voltage profile at the distant receiving end reducing power delivery. This issue worsens with the large-scale influx of electric vehicles and power converter-fed loads, which draw constant power irrespective of supply voltage. Such loads exhibit negative incremental resistance behavior and also have a dynamic response which affects the network in a manner different from constant impedance loads. This paper compares the effects of constant power and constant impedance loads by modeling adjustable converter dynamics for constant power loads. It analyzes line currents, load voltages and power transmitted in a four-load radial test system with optional distributed sources. Results show poorer voltage profile and the effect of power converter dynamics in constant power loads compared to conventional loads. Adding distributed sources improves voltage profile considerably, and transmission losses are reduced. Steady state analysis is then extended to an IEEE 31-bus 23 kV distribution test system with similar results. Transmission losses are computed along different branches, and the influence of loads and sources are analyzed. The outcomes of the analysis can be used in arrival of loss allocation in a system where peer to peer energy sharing is envisaged.

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • PES University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A comparative analysis of constant impedance and constant power loads in a distribution network</dc:title><dc:creator>Ramya, Ramya</dc:creator><dc:creator>Joseph, Rex</dc:creator><dc:description>&lt;jats:p&gt;Most conventional power systems adopt radial distribution network wherein multiple loads are connected across the distribution transformer. As the number of loads increases, it results in poor voltage profile at the distant receiving end reducing power delivery. This issue worsens with the large-scale influx of electric vehicles and power converter-fed loads, which draw constant power irrespective of supply voltage. Such loads exhibit negative incremental resistance behavior and also have a dynamic response which affects the network in a manner different from constant impedance loads. This paper compares the effects of constant power and constant impedance loads by modeling adjustable converter dynamics for constant power loads. It analyzes line currents, load voltages and power transmitted in a four-load radial test system with optional distributed sources. Results show poorer voltage profile and the effect of power converter dynamics in constant power loads compared to conventional loads. Adding distributed sources improves voltage profile considerably, and transmission losses are reduced. Steady state analysis is then extended to an IEEE 31-bus 23 kV distribution test system with similar results. Transmission losses are computed along different branches, and the influence of loads and sources are analyzed. The outcomes of the analysis can be used in arrival of loss allocation in a system where peer to peer energy sharing is envisaged.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i6.pp6111-6121</dc:identifier><dc:identifier>10.11591/ijece.v14i6.pp6111-6121</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 6 (2024); 6111</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35989/17763</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>