Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

An automated power of hydrogen controlled filtration system for enhanced aquarium fish farming

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 14 No. 6 (2024)

DOI
10.11591/ijece.v14i6.pp6265-6270
ISSN
2722-2578, 2088-8708
Published
2024-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The increasing popularity of fish keeping in aquariums and the need for electronic equipment to maintain an optimal environment. This article focuses on monitoring water purity to ensure fish health and longevity, addressing the issue of water pollution caused by chemicals and waste produced by fish. Solutions such as mechanical and biological filters are explored, highlighting the use of the mechanical filter composed of zeolite, ceramic rings, and activated carbon, which work to remove solid particles, toxic compounds, and pollutants from the aquarium water. The article presents the implementation of a mechanical filter controlled by a PIC18F4550 microcontroller using a pH sensor. The results indicate the stability of the pH of the water in the established range of 6.5 to 7.5, with a maximum error of 3% at the upper limit of the range and no error below the established lower limit. It is concluded that the system effectively maintains the desired levels and ensures the fish's health. A technological solution for monitoring and controlling water quality is presented, recognizing the possibility of improvements in aquaculture.

Collaboration network of the authors

17 authors · 33 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad Tecnológica del Perú
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Johan Huaman CastañedaUniversidad Tecnológica del Perú1
Pablo Cesar Tamara PerezUniversidad Tecnológica del Perú1
Guillermo Wenceslao Zarate SeguraUniversidad Tecnológica del Perú1
Diego Gonzales-RodriguezUniversidad Tecnológica del Perú1
William Trujillo HerreraUniversidad Tecnológica del Perú1
Juan J. SoriaUniversidad Tecnológica del Perú1
Diana Quispe-ArpasiUniversidad Tecnológica del Perú1
Christian OvalleUniversidad Tecnológica del Perú1
Napoly MeloUniversidad Tecnológica del Perú1
Abigail Sanchez GonzalesUniversidad Tecnológica del Perú1
Kevin Murga-GarciaUniversidad Tecnológica del Perú1
Rodrigo Chacaltana-SilvaUniversidad Tecnológica del Perú1
José Rodríguez-GonzalesUniversidad Tecnológica del Perú1
Junior Niquin-JaimesUniversidad Tecnológica del Perú1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>An automated power of hydrogen controlled filtration system for enhanced aquarium fish farming</dc:title><dc:creator>Garcia, Fabio</dc:creator><dc:creator>Martel, Daniel</dc:creator><dc:creator>Paiva-Peredo, Ernesto</dc:creator><dc:description>&lt;jats:p&gt;The increasing popularity of fish keeping in aquariums and the need for electronic equipment to maintain an optimal environment. This article focuses on monitoring water purity to ensure fish health and longevity, addressing the issue of water pollution caused by chemicals and waste produced by fish. Solutions such as mechanical and biological filters are explored, highlighting the use of the mechanical filter composed of zeolite, ceramic rings, and activated carbon, which work to remove solid particles, toxic compounds, and pollutants from the aquarium water. The article presents the implementation of a mechanical filter controlled by a PIC18F4550 microcontroller using a pH sensor. The results indicate the stability of the pH of the water in the established range of 6.5 to 7.5, with a maximum error of 3% at the upper limit of the range and no error below the established lower limit. It is concluded that the system effectively maintains the desired levels and ensures the fish's health. A technological solution for monitoring and controlling water quality is presented, recognizing the possibility of improvements in aquaculture.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2024-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v14i6.pp6265-6270</dc:identifier><dc:identifier>10.11591/ijece.v14i6.pp6265-6270</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 14 No 6 (2024); 6265</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/35271/17777</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>