Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Electrocardiogram features detection using stationary wavelet transform

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 1 (2025)

DOI
10.11591/ijece.v15i1.pp374-385
ISSN
2722-2578, 2088-8708
Published
2025-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The main objective of this paper is to provide a novel stationary wavelet transform (SWT) based method for electrocardiogram (ECG) feature detection. The proposed technique uses the detail coefficients of the ECG signal decomposition by SWT and the selection of the appropriate coefficient to detect a specific wave of the signal. Indeed, the temporal and frequency analysis of these coefficients allowed us to choose detail coefficient of level 2 (Cd2) to detect the R peaks. In contrast, the coefficient of level 3 (Cd3) is determined to extract the Q, S, P, and T waves from the ECG. The proposed method was tested on recordings from the apnea and Massachusetts Institute of Technology–Beth Israel hospital (MIT-BIH) databases. The performances obtained are excellent. Indeed, the technique presents a sensitivity of 99.83%, a predictivity of 99.72%, and an error rate of 0.44%. A further important advantage of the method is its ability to detect different waves even in the presence of baseline wander (BLW) of the ECG signal. This property makes it possible to bypass the filtering operation of BLW.

Collaboration network of the authors

8 authors · 11 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Université Sultan Moulay Slimane
  • Mohammed V University
  • Lyon 1 Université
  • University of Hassan II Casablanca
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Larbi BellarbiMohammed V University2
Abdelhamid ErrachidLyon 1 Université2
Mohamed MoutchouUniversity of Hassan II Casablanca1
Hicham StitouUniversité Sultan Moulay Slimane1
Mohamed Amine AtillahUniversité Sultan Moulay Slimane1
Abdelghani BoudaoudUniversité Sultan Moulay Slimane1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Electrocardiogram features detection using stationary wavelet transform</dc:title><dc:creator>Aqil, Mounaim</dc:creator><dc:creator>Jbari, Atman</dc:creator><dc:description>&lt;jats:p&gt;The main objective of this paper is to provide a novel stationary wavelet transform (SWT) based method for electrocardiogram (ECG) feature detection. The proposed technique uses the detail coefficients of the ECG signal decomposition by SWT and the selection of the appropriate coefficient to detect a specific wave of the signal. Indeed, the temporal and frequency analysis of these coefficients allowed us to choose detail coefficient of level 2 (Cd2) to detect the R peaks. In contrast, the coefficient of level 3 (Cd3) is determined to extract the Q, S, P, and T waves from the ECG. The proposed method was tested on recordings from the apnea and Massachusetts Institute of Technology–Beth Israel hospital (MIT-BIH) databases. The performances obtained are excellent. Indeed, the technique presents a sensitivity of 99.83%, a predictivity of 99.72%, and an error rate of 0.44%. A further important advantage of the method is its ability to detect different waves even in the presence of baseline wander (BLW) of the ECG signal. This property makes it possible to bypass the filtering operation of BLW.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i1.pp374-385</dc:identifier><dc:identifier>10.11591/ijece.v15i1.pp374-385</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 1 (2025); 374</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36189/17947</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>