The grounding system in substations generally uses electrode rods, because electrodes can affect the effectiveness of fault current conduction, so the equipment will be safer. Considering the importance of the grounding system, the installed grounding system must be considered and maintained properly. One of them is the grounding found in Glugur. The main objective of this research is to comprehensively evaluate the substation grounding system by modeling the grounding system at the Glugur Substation using MATLAB graphical user interface (GUI). The grounding resistance follows a grid system with an area of 20×15=300 m² with specific resistance being clay using 100 rod electrodes. From the results of ground resistance simulation modeling using MATLAB GUI, it can be concluded as follows: for a certain resistance value, the number of electrodes for 100 Ωm is 3.55 Ω, for ground resistance with a constant depth and a varying number of 100 electrodes, it is 3.45 Ω, and for. The grounding resistance with a constant and varying number of 1,000 rods is obtained at 2.65 Ω. From these results, the modeling carried out is in accordance with the standards of electricity regulations in Indonesia.

Collaboration network of the authors

10 authors · 21 co-authorship links · 17 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • Al-Azhar University
  • Universitas Harapan Medan
  • Universitas Prima Indonesia
  • University of Technology Malaysia
  • Universiti Malaysia Perlis
  • Universitas Bung Hatta
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nor Hanisah BaharudinUniversiti Malaysia Perlis2
Indra NisjaUniversitas Bung Hatta2
Sharul Kamal Abdul RahimUniversity of Technology Malaysia1
Mohamad Harris MisranUniversiti Teknikal Malaysia Melaka1
Maizatul Alice Meor SaidUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Modeling of Glugur Substation grounding systems using MATLAB graphical user interface</dc:title><dc:creator>Roza, Indra</dc:creator><dc:creator>Nugraha, Yoga Tri</dc:creator><dc:creator>Rida, Rizkha</dc:creator><dc:creator>Irwanto, Muhammad</dc:creator><dc:creator>Othman, Mohd. Azlishah</dc:creator><dc:description>&lt;jats:p&gt;The grounding system in substations generally uses electrode rods, because electrodes can affect the effectiveness of fault current conduction, so the equipment will be safer. Considering the importance of the grounding system, the installed grounding system must be considered and maintained properly. One of them is the grounding found in Glugur. The main objective of this research is to comprehensively evaluate the substation grounding system by modeling the grounding system at the Glugur Substation using MATLAB graphical user interface (GUI). The grounding resistance follows a grid system with an area of 20×15=300 m² with specific resistance being clay using 100 rod electrodes. From the results of ground resistance simulation modeling using MATLAB GUI, it can be concluded as follows: for a certain resistance value, the number of electrodes for 100 Ωm is 3.55 Ω, for ground resistance with a constant depth and a varying number of 100 electrodes, it is 3.45 Ω, and for. The grounding resistance with a constant and varying number of 1,000 rods is obtained at 2.65 Ω. From these results, the modeling carried out is in accordance with the standards of electricity regulations in Indonesia.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i1.pp15-23</dc:identifier><dc:identifier>10.11591/ijece.v15i1.pp15-23</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 1 (2025); 15</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36143/17905</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>