Abstract

The construction of new relay protection systems without the use of current transformers is a fundamental problem of electro energetics, which has not yet been solved. This works suggests a negative-sequence current filter which receives information from inductance coils (ICs) mounted at a safe distance in the magnetic field of phase currents. This filter does not require current transformers, thus saving high-quality copper, steel, and expensive high-voltage insulation in amount unprecedented for relay protection (a 6 to 110 kV current transformer has 19 to 480 kg in weight). A circuit (including functional diagnostics) and a technique for selecting the parameters of filter components and the points where ICs should be fixed are presented; a structure for IC fastening is described. Computer simulation and experiment were used for data collection. The data show that i) the filter conversion coefficient m= 1.6, and imbalance increases by 7% at the network frequency f= 48–52 Hz; ii) protections based on this filter should have a time delay; iii) the filter is not inferior to well-known well-tested filters with current transformers; and iv) it is functional, but can only be used for single-standing electrical installations.

Collaboration network of the authors

4 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Toraighyrov University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Negative-sequence current filter based on inductance coils</dc:title><dc:creator>Kletsel, Mark</dc:creator><dc:creator>Mashrapov, Bauyrzhan</dc:creator><dc:creator>Mashrapova, Rizagul</dc:creator><dc:creator>Kislov, Alexandr</dc:creator><dc:description>&lt;jats:p&gt;The construction of new relay protection systems without the use of current transformers is a fundamental problem of electro energetics, which has not yet been solved. This works suggests a negative-sequence current filter which receives information from inductance coils (ICs) mounted at a safe distance in the magnetic field of phase currents. This filter does not require current transformers, thus saving high-quality copper, steel, and expensive high-voltage insulation in amount unprecedented for relay protection (a 6 to 110 kV current transformer has 19 to 480 kg in weight). A circuit (including functional diagnostics) and a technique for selecting the parameters of filter components and the points where ICs should be fixed are presented; a structure for IC fastening is described. Computer simulation and experiment were used for data collection. The data show that i) the filter conversion coefficient m= 1.6, and imbalance increases by 7% at the network frequency f= 48–52 Hz; ii) protections based on this filter should have a time delay; iii) the filter is not inferior to well-known well-tested filters with current transformers; and iv) it is functional, but can only be used for single-standing electrical installations.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i1.pp24-35</dc:identifier><dc:identifier>10.11591/ijece.v15i1.pp24-35</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 1 (2025); 24</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36740/17906</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>