Abstract

The performance of an atomic facility depends on the efficient supply of electricity, particularly emergency loads like monitoring and control equipment, radiation safety systems, and emergency lights. Most nuclear facilities rely on diesel generators to supply emergency loads during grid outages. Due to the diesel generator's imperfections, such as its starting time, it may fail to deliver power because it is unavailable due to maintenance, failure to start, or failure to run and supply the load. It cannot immediately supply the critical loads, resulting in a blackout and the release of radioactive substances into the environment. To address the previous issues, this paper proposes an improved method to enhance the reliability of nuclear facilities for providing electricity to safety and critical consumers during normal and emergency operating modes. The approach incorporates a photovoltaic (PV) system/battery, and its robustness and performance are tested using load flow and transient stability analysis. The simulation results demonstrated the effectiveness and speed of the proposed method when compared to the traditional method, as the emergency consumers were successfully powered within a very short time without fluctuations, and the voltage reduction and frequency were within the nominal values. The electrical transient analyzer program (ETAP) is used to validate these results.

Collaboration network of the authors

5 authors · 6 co-authorship links · 1 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Egyptian Atomic Energy Authority
  • Al-Azhar University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Montaser HafezAffiliation unknown1
Nabil AyadAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhancing the reliance of emergency power supply systems for nuclear facilities using hybrid system</dc:title><dc:creator>Saade, Mohammed</dc:creator><dc:creator>El-Eissawi, Hussein</dc:creator><dc:creator>Nada, Adel S.</dc:creator><dc:description>&lt;jats:p&gt;The performance of an atomic facility depends on the efficient supply of electricity, particularly emergency loads like monitoring and control equipment, radiation safety systems, and emergency lights. Most nuclear facilities rely on diesel generators to supply emergency loads during grid outages. Due to the diesel generator's imperfections, such as its starting time, it may fail to deliver power because it is unavailable due to maintenance, failure to start, or failure to run and supply the load. It cannot immediately supply the critical loads, resulting in a blackout and the release of radioactive substances into the environment. To address the previous issues, this paper proposes an improved method to enhance the reliability of nuclear facilities for providing electricity to safety and critical consumers during normal and emergency operating modes. The approach incorporates a photovoltaic (PV) system/battery, and its robustness and performance are tested using load flow and transient stability analysis. The simulation results demonstrated the effectiveness and speed of the proposed method when compared to the traditional method, as the emergency consumers were successfully powered within a very short time without fluctuations, and the voltage reduction and frequency were within the nominal values. The electrical transient analyzer program (ETAP) is used to validate these results.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i1.pp36-45</dc:identifier><dc:identifier>10.11591/ijece.v15i1.pp36-45</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 1 (2025); 36</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36939/17907</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>