Vital signal monitoring acts as a highly significant diagnostic method. Continuous monitoring of vital signs like temperature, heart rate, and blood pressure aids in easy and fast disease diagnosis. Existing methods that enable continuous monitoring, such as smart watches, are not accurate enough to be used as a benchmark for diagnosing diseases. In this paper, we propose simultaneous temperature and heart rate measurement using tilted fiber Bragg grating (TFBG) which enables concurrent measurement of measurands due to its intrinsic optical property. Temperature and heart rate were considered for measurement. The proposed TFBG-based optical sensor has a sensitivity of 11.81 pm/°C and 1.73 pm/µε towards variation in temperature and strain, respectively. The sensitivity was determined by a shift in the wavelength of core mode resonance for temperature and a differential change in the wavelength of cladding mode resonance for heart rate. The average response time of the proposed TFBG sensor was found to be 3 seconds. Accuracy of 99.68% and 98.42% were achieved in temperature and heart rate measurements by the proposed TFBG sensor. The acceptability of the proposed TFBG sensor was analyzed using the Bland- Altman plot.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SRM Institute of Science and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 22 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Tilted fiber Bragg grating based optical sensor for simultaneous measurement of vital signs: a novel approach</dc:title><dc:creator>Arumugam, Ramya</dc:creator><dc:creator>Kumar, Ramamoorthy</dc:creator><dc:creator>Dhanalakshmi, Samiappan</dc:creator><dc:description>&lt;jats:p&gt;Vital signal monitoring acts as a highly significant diagnostic method. Continuous monitoring of vital signs like temperature, heart rate, and blood pressure aids in easy and fast disease diagnosis. Existing methods that enable continuous monitoring, such as smart watches, are not accurate enough to be used as a benchmark for diagnosing diseases. In this paper, we propose simultaneous temperature and heart rate measurement using tilted fiber Bragg grating (TFBG) which enables concurrent measurement of measurands due to its intrinsic optical property. Temperature and heart rate were considered for measurement. The proposed TFBG-based optical sensor has a sensitivity of 11.81 pm/°C and 1.73 pm/µε towards variation in temperature and strain, respectively. The sensitivity was determined by a shift in the wavelength of core mode resonance for temperature and a differential change in the wavelength of cladding mode resonance for heart rate. The average response time of the proposed TFBG sensor was found to be 3 seconds. Accuracy of 99.68% and 98.42% were achieved in temperature and heart rate measurements by the proposed TFBG sensor. The acceptability of the proposed TFBG sensor was analyzed using the Bland- Altman plot.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i2.pp1434-1445</dc:identifier><dc:identifier>10.11591/ijece.v15i2.pp1434-1445</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 2 (2025); 1434</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36914/18067</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>