Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Electroencephalography classification technique based on statistical denoising and modified k-nearest neighbor algorithm with bipolar sigmoid rectified linear unit’s function

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 3 (2025)

DOI
10.11591/ijece.v15i3.pp2786-2795
ISSN
2722-2578, 2088-8708
Published
2025-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Accurate classification of electroencephalography (EEG) data is much needed for early identification of diseases to treat various disorders. In this paper, we propose EEG classification technique based on statistical denoising & modified k-nearest neighbor (k-NN) algorithm with bipolar sigmoid rectified linear units (ReLU) function. The EEG data is subjected to statistical methods to remove the artifacts and then applied to modified k-NN algorithm to categorize the appropriate features giving preference to neighbors closer to one another considering the weighted votes of the k-nearest neighbors before selecting the class label based on the highest weighted vote. A customized activation function that combines these two functions called as hybrid function that uses various portions of each function in particular ranges is used in our work i.e., use of bipolar sigmoid for negative values and the ReLU function for positive values which helps to limit the signal in a particular range. The proposed algorithm's detection accuracy is tested for the confusion matrix of true positive (TP), false positive (FP), false negative (FN)and true negative (TN) and compared to the detection accuracy of other existing algorithms, demonstrating the algorithm's efficiency with a classification accuracy of almost 85 percent and sensitivity of 91% for standard Kaggle Dataset.

Collaboration network of the authors

4 authors · 6 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • CMR University
  • REVA University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Electroencephalography classification technique based on statistical denoising and modified k-nearest neighbor algorithm with bipolar sigmoid rectified linear unit’s function</dc:title><dc:creator>Mahalingegowda, Thejaswini Bekkalale</dc:creator><dc:creator>George, Glan Devadhas</dc:creator><dc:creator>Yoga, Satheesha Tumakur</dc:creator><dc:creator>Ezhilarasan, Kaliyamoorthy</dc:creator><dc:description>&lt;jats:p&gt;Accurate classification of electroencephalography (EEG) data is much needed for early identification of diseases to treat various disorders. In this paper, we propose EEG classification technique based on statistical denoising &amp;amp;amp; modified k-nearest neighbor (k-NN) algorithm with bipolar sigmoid rectified linear units (ReLU) function. The EEG data is subjected to statistical methods to remove the artifacts and then applied to modified k-NN algorithm to categorize the appropriate features giving preference to neighbors closer to one another considering the weighted votes of the k-nearest neighbors before selecting the class label based on the highest weighted vote. A customized activation function that combines these two functions called as hybrid function that uses various portions of each function in particular ranges is used in our work i.e., use of bipolar sigmoid for negative values and the ReLU function for positive values which helps to limit the signal in a particular range. The proposed algorithm's detection accuracy is tested for the confusion matrix of true positive (TP), false positive (FP), false negative (FN)and true negative (TN) and compared to the detection accuracy of other existing algorithms, demonstrating the algorithm's efficiency with a classification accuracy of almost 85 percent and sensitivity of 91% for standard Kaggle Dataset.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i3.pp2786-2795</dc:identifier><dc:identifier>10.11591/ijece.v15i3.pp2786-2795</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 3 (2025); 2786</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/36873/18223</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>