Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Genetic algorithm-adapted activation function optimization of deep learning framework for breast mass cancer classification in mammogram images

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 3 (2025)

DOI
10.11591/ijece.v15i3.pp2820-2833
ISSN
2722-2578, 2088-8708
Published
2025-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The convolutional neural network (CNN) has been explored for mammogram cancer classification to aid radiologists. CNNs require multiple convolution and non-linearity repetitions to learn data sparsity, but deeper networks often face the vanishing gradient effect, which hinders effective learning. The rectified linear unit (ReLU) activation function activates neurons only when the output exceeds zero, limiting activation and potentially lowering performance. This study proposes an adaptive ReLU based on a genetic algorithm (GA) to determine the optimal threshold for neuron activation, thus improving the restrictive nature of the original ReLU. We compared performances on the INbreast and IPPT-mammo mammogram datasets using ReLU and leakyReLU activation functions. Results show accuracy improvements from 95.0% to 97.01% for INbreast and 84.9% to 87.4% for IPPT-mammo with ReLU and from 93.03% to 99.0% for INbreast and 84.03% to 91.06% for IPPT-mammo with leakyReLU. Significant accuracy improvements were observed for breast cancer classification in mammograms, demonstrating its potential to aid radiologists with more robust and reliable diagnostic tools.

Collaboration network of the authors

12 authors · 35 co-authorship links · 7 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknologi MARA
  • Universiti Sains Malaysia
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Samsul SetuminUniversiti Teknologi MARA8
Mohd Firdaus AbdullahUniversiti Teknologi MARA4
Hasnain AbdullahUniversiti Teknologi MARA1
Nazirah Mohamat KasimUniversiti Teknologi MARA1
Noor Azila IsmailUniversiti Teknologi MARA1
Zafirah FaizaUniversiti Teknologi MARA1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Genetic algorithm-adapted activation function optimization of deep learning framework for breast mass cancer classification in mammogram images</dc:title><dc:creator>Razali, Noor Fadzilah</dc:creator><dc:creator>Isa, Iza Sazanita</dc:creator><dc:creator>Sulaiman, Siti Noraini</dc:creator><dc:creator>Osman, Muhammad Khusairi</dc:creator><dc:creator>Karim, Noor Khairiah A.</dc:creator><dc:creator>Damit, Dayang Suhaida Awang</dc:creator><dc:description>&lt;jats:p&gt;The convolutional neural network (CNN) has been explored for mammogram cancer classification to aid radiologists. CNNs require multiple convolution and non-linearity repetitions to learn data sparsity, but deeper networks often face the vanishing gradient effect, which hinders effective learning. The rectified linear unit (ReLU) activation function activates neurons only when the output exceeds zero, limiting activation and potentially lowering performance. This study proposes an adaptive ReLU based on a genetic algorithm (GA) to determine the optimal threshold for neuron activation, thus improving the restrictive nature of the original ReLU. We compared performances on the INbreast and IPPT-mammo mammogram datasets using ReLU and leakyReLU activation functions. Results show accuracy improvements from 95.0% to 97.01% for INbreast and 84.9% to 87.4% for IPPT-mammo with ReLU and from 93.03% to 99.0% for INbreast and 84.03% to 91.06% for IPPT-mammo with leakyReLU. Significant accuracy improvements were observed for breast cancer classification in mammograms, demonstrating its potential to aid radiologists with more robust and reliable diagnostic tools.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i3.pp2820-2833</dc:identifier><dc:identifier>10.11591/ijece.v15i3.pp2820-2833</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 3 (2025); 2820</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/37401/18226</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>