Abstract

Persistent electrical supply requires the power systems to be stable and reliable. Against varying load conditions, control strategies such as load frequency control (LFC) is a key mechanism to protect its stability. Traditional control strategies for LFC often face challenges due to system uncertainties, external disturbances, and nonlinearities. This paper presents an advanced approach to control load frequency and enhancing LFC in power systems by using sliding mode control (SMC). SMC offers powerful stability and robustness versus nonlinearities and perturbation, making it a promising approach for addressing the limitations of conventional control methods. We contemporary a comprehensive analysis of the SMC approach tailored for LFC, including the strategy and employment of the control algorithm. The proposed method makes use of a sliding/gliding surface to enable the system trajectories to be continuous on this surface despite parameter variations and external disturbances. Simulation results demonstrate significant improvements in frequency stability and system performance compared to conventional proportional-integral-derivative (PID) controllers. The paper also includes a comparative analysis of SMC with other modern control techniques, highlighting its advantages in terms of robustness and adaptability.

Collaboration network of the authors

11 authors · 30 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Ton Duc Thang University
  • Van Lang University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Van-Duc PhanVan Lang University1
Hoan Bao LaiTon Duc Thang University1
Anh-Tuan TranAffiliation unknown1
Emmanuel Nduka AmaefuleTon Duc Thang University1
Phong Thanh TranTon Duc Thang University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Load frequency control for integrated hydro and thermal power plant power system</dc:title><dc:creator>Nguyen, Vu Tan</dc:creator><dc:creator>Tran, Thinh Lam-The</dc:creator><dc:creator>Tuan, Dao Huy</dc:creator><dc:creator>Hien, Dinh Cong</dc:creator><dc:creator>Nguyen, Vinh Phuc</dc:creator><dc:creator>Huynh, Van Van</dc:creator><dc:description>&lt;jats:p&gt;Persistent electrical supply requires the power systems to be stable and reliable. Against varying load conditions, control strategies such as load frequency control (LFC) is a key mechanism to protect its stability. Traditional control strategies for LFC often face challenges due to system uncertainties, external disturbances, and nonlinearities. This paper presents an advanced approach to control load frequency and enhancing LFC in power systems by using sliding mode control (SMC). SMC offers powerful stability and robustness versus nonlinearities and perturbation, making it a promising approach for addressing the limitations of conventional control methods. We contemporary a comprehensive analysis of the SMC approach tailored for LFC, including the strategy and employment of the control algorithm. The proposed method makes use of a sliding/gliding surface to enable the system trajectories to be continuous on this surface despite parameter variations and external disturbances. Simulation results demonstrate significant improvements in frequency stability and system performance compared to conventional proportional-integral-derivative (PID) controllers. The paper also includes a comparative analysis of SMC with other modern control techniques, highlighting its advantages in terms of robustness and adaptability.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i4.pp3583-3592</dc:identifier><dc:identifier>10.11591/ijece.v15i4.pp3583-3592</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 4 (2025); 3583</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/37482/18407</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>