Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Enhancing source currents and ensuring load voltage stability in railway electrification system via unified power quality conditions implementation

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 5 (2025)

DOI
10.11591/ijece.v15i5.pp4430-4444
ISSN
2722-2578, 2088-8708
Published
2025-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

In recent years, interest in electric railway system as a transportation solution for large urban areas has grown significantly. This increased attention stems from several key advantages, including environmental friendliness, high performance, reduced maintenance costs, and lower energy expenses. Railway electrification system rely on supplying power to trains through single-phase transformers. However, these transformers can cause issues such as current imbalances and harmonics at the system connection point, which may impact critical loads. Additionally, fluctuations in source voltage can influence the system's performance. This study examines the causes of unbalanced loading in railway electrification system and introduces an innovative unified power quality conditioner (UPQC) specifically designed for integration into low-voltage railway electrification system. The proposed UPQC aims to restore current balance, minimize harmonics, and enhance overall power quality. Furthermore, it addresses the mitigation of voltage sags in the power distribution network. The simulation results generated through MATLAB programming demonstrate the UPQC's effectiveness in enhancing system performance. The findings reveal that the UPQC reduces source current imbalance to less than 1.6% and total harmonic distortion (THD) to below 4.89% across all test scenarios. Additionally, the UPQC successfully maintains a load bus voltage of 25 kV during single-phase-to-ground and unbalanced three-phase-to-ground fault conditions.

Collaboration network of the authors

5 authors · 6 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Rajamangala University of Technology Isan
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Akkachai PhuphaninRajamangala University of Technology Isan1
Metha TasakornRajamangala University of Technology Isan1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Enhancing source currents and ensuring load voltage stability in railway electrification system via unified power quality conditions implementation</dc:title><dc:creator>Somsai, Kittaya</dc:creator><dc:creator>Srivichai, Jeerapong</dc:creator><dc:creator>Thanyaphirak, Veera</dc:creator><dc:description>&lt;jats:p&gt;In recent years, interest in electric railway system as a transportation solution for large urban areas has grown significantly. This increased attention stems from several key advantages, including environmental friendliness, high performance, reduced maintenance costs, and lower energy expenses. Railway electrification system rely on supplying power to trains through single-phase transformers. However, these transformers can cause issues such as current imbalances and harmonics at the system connection point, which may impact critical loads. Additionally, fluctuations in source voltage can influence the system's performance. This study examines the causes of unbalanced loading in railway electrification system and introduces an innovative unified power quality conditioner (UPQC) specifically designed for integration into low-voltage railway electrification system. The proposed UPQC aims to restore current balance, minimize harmonics, and enhance overall power quality. Furthermore, it addresses the mitigation of voltage sags in the power distribution network. The simulation results generated through MATLAB programming demonstrate the UPQC's effectiveness in enhancing system performance. The findings reveal that the UPQC reduces source current imbalance to less than 1.6% and total harmonic distortion (THD) to below 4.89% across all test scenarios. Additionally, the UPQC successfully maintains a load bus voltage of 25 kV during single-phase-to-ground and unbalanced three-phase-to-ground fault conditions.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i5.pp4430-4444</dc:identifier><dc:identifier>10.11591/ijece.v15i5.pp4430-4444</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 5 (2025); 4430</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/38948/18416</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>