Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Analysis of partial discharge characteristics in transformer oil insulation media using needle-plane and plane-plane electrode systems

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 5 (2025)

DOI
10.11591/ijece.v15i5.pp4445-4453
ISSN
2722-2578, 2088-8708
Published
2025-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Insulation failure is a common issue in electric power transmission. Insulation is necessary to separate two or more live conductors to prevent electrical arcing or sparking between them. Partial discharge (PD) is a phenomenon that can also occur in high-voltage equipment under pre-breakdown conditions. This PD activity can take place in liquid insulation, such as transformer oil, leading to a decrease in the quality and reliability of the transformer. This study aims to detect PD under various conditions and investigate its characteristics. Although various studies have been conducted on PD in liquid insulation, most of them focus on PD characterization under specific conditions without considering variations in electrode configurations that may influence the PD phenomenon. Therefore, this research is necessary to fill this gap by analyzing PD characteristics using a needle-plane and plane-plane electrode system. This study introduces the use of castor oil as an alternative liquid insulating material. In this study, PD testing will be conducted in a laboratory environment, and it is expected to produce reliable data regarding the capability of liquid insulation to withstand PD. The results obtained indicate that the PD phenomenon occurs more quickly in the needle-plane electrode configuration compared to the plane-plane configuration. PD in the needle-plane electrode occurs at an average voltage of 10.96 kV, while PD in the plane-plane electrode occurs at an average voltage of 12.5 kV.

Collaboration network of the authors

10 authors · 18 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Diponegoro University
  • Sultan Agung Islamic University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Yudha Agung SubarkahDiponegoro University2
Agung WarsitoDiponegoro University1
Galuh SusilowatiDiponegoro University1
Arief MarwantoSultan Agung Islamic University1
Sukarno Budi UtomoDiponegoro University1
Berkah FajarDiponegoro University1
Sonny Hady WinotoAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Analysis of partial discharge characteristics in transformer oil insulation media using needle-plane and plane-plane  electrode systems</dc:title><dc:creator>Murad, Teuku Khairul</dc:creator><dc:creator>Syakur, Abdul</dc:creator><dc:creator>Setiawan, Iwan</dc:creator><dc:description>&lt;jats:p&gt;Insulation failure is a common issue in electric power transmission. Insulation is necessary to separate two or more live conductors to prevent electrical arcing or sparking between them. Partial discharge (PD) is a phenomenon that can also occur in high-voltage equipment under pre-breakdown conditions. This PD activity can take place in liquid insulation, such as transformer oil, leading to a decrease in the quality and reliability of the transformer. This study aims to detect PD under various conditions and investigate its characteristics. Although various studies have been conducted on PD in liquid insulation, most of them focus on PD characterization under specific conditions without considering variations in electrode configurations that may influence the PD phenomenon. Therefore, this research is necessary to fill this gap by analyzing PD characteristics using a needle-plane and plane-plane electrode system. This study introduces the use of castor oil as an alternative liquid insulating material. In this study, PD testing will be conducted in a laboratory environment, and it is expected to produce reliable data regarding the capability of liquid insulation to withstand PD. The results obtained indicate that the PD phenomenon occurs more quickly in the needle-plane electrode configuration compared to the plane-plane configuration. PD in the needle-plane electrode occurs at an average voltage of 10.96 kV, while PD in the plane-plane electrode occurs at an average voltage of 12.5 kV.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i5.pp4445-4453</dc:identifier><dc:identifier>10.11591/ijece.v15i5.pp4445-4453</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 5 (2025); 4445</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/39063/18417</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>