Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Power loss reduction and stability enhancement of power system through transmission network reconfiguration

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 15 No. 6 (2025)

DOI
10.11591/ijece.v15i6.pp6012-6026
ISSN
2722-2578, 2088-8708
Published
2025-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

The power network faces several challenges as electricity usage rises and the frequency of partial and total grid disruptions is of great concern. This paper addresses the problem of voltage instability and high-power losses in transmission network, which threatens the stability of the power grid. The MATLAB R2023a/MATPOWER 5.0 is used to develop a model and analyze using the Newton-Raphson load flow method. The analysis reveals a marginal voltage violation at Bus 13 (below 0.95 p.u.). To enhance stability and efficiency, the network was reconfigured using a hybrid whale algorithm and particle swarm optimization (WAPSO) approach, incorporating new transmission lines (5-8 and 13-14) to improve connectivity and reduce congestion. The reconfiguration reduced active power losses by 29.5% (from 36.013 to 25.371 MW) and reactive power losses by 29.8% (from 301.30 to 211.59 MVAr). The system demonstrated first swing stability, with rotor angles remaining below π/2 (1.5669 rad maximum deviation) and fault clearance within the critical clearing time (0.2 s). Optimized exciter gains and a damping coefficient of 1.5 p.u. ensured effective oscillation suppression and stable generator voltages at 1.05 p.u. The hybrid WAPSO approach proved effective in optimizing voltage and rotor angle stability, enabling the network to meet a 24.086 p.u. load demand while enhancing overall grid reliability.

Collaboration network of the authors

40 authors · 94 co-authorship links · 50 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Teknikal Malaysia Melaka
  • University of Technology Malaysia
  • Islamic Azad University, Tehran
  • University of Nigeria
  • Universitas Ahmad Dahlan
  • Sultan Agung Islamic University
  • Tun Hussein Onn University of Malaysia
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nik Rumzi Nik IdrisUniversity of Technology Malaysia9
Mohammad JannatiUniversity of Technology Malaysia9
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka8
Mohd Junaidi Abdul AzizUniversity of Technology Malaysia7
Mustafa ManapUniversiti Teknikal Malaysia Melaka7
Awang JusohUniversity of Technology Malaysia7
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka6
M. Rahimi YusoffUniversiti Teknikal Malaysia Melaka4
Muhammad AdoUniversity of Technology Malaysia4
Lina HandayaniUniversitas Ahmad Dahlan3
Imam Much Ibnu SubrotoSultan Agung Islamic University3
Shahreen binti KasimTun Hussein Onn University of Malaysia3
Mahmoud ZadehbagheriIslamic Azad University, Tehran3
Mohammad Javad KianiIslamic Azad University, Tehran3
Vahdat NazerianUniversity of Mazandaran3
Auzani JidinUniversiti Teknikal Malaysia Melaka2
M. GhanbariAffiliation unknown2
Munawar Agus RiyadiDiponegoro University2
Deris StiawanSriwijaya University2
M. Najafi KhoshrodiAffiliation unknown2
A.S. HussinUniversiti Teknikal Malaysia Melaka2
Mohd Ruddin Ab GhaniUniversiti Teknikal Malaysia Melaka2
Mehdi DadkhahIslamic Azad University, Tehran2
Shahaboddin ShamshirbandUniversity of Malaya2
Ahmad Saudi SamosirLampung University2
Ali AjamiAffiliation unknown2
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka1
Rozana AlikUniversity of Technology Malaysia1
M.F. HabbanUniversiti Teknikal Malaysia Melaka1
Muhammad Firdaus Abd RazakUniversity of Technology Malaysia1
Mohamad Hamka Bin SaifulUniversity of Technology Malaysia1
Abdul Rashid HusainUniversity of Technology Malaysia1
Sahazati Md RozaliUniversiti Teknikal Malaysia Melaka1
Muhammad Nizam KamarudinUniversiti Teknikal Malaysia Melaka1
Abdulhamid Usman MutawakkilUniversity of Technology Malaysia1
Moloud AbdarDamghan University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Power loss reduction and stability enhancement of power system through transmission network reconfiguration</dc:title><dc:creator>Akor, Titus Terwase</dc:creator><dc:creator>Madueme, Theophilu Chukwudolue</dc:creator><dc:creator>Ohanu, Chibuike Peter</dc:creator><dc:creator>Sutikno, Tole</dc:creator><dc:description>&lt;jats:p&gt;The power network faces several challenges as electricity usage rises and the frequency of partial and total grid disruptions is of great concern. This paper addresses the problem of voltage instability and high-power losses in transmission network, which threatens the stability of the power grid. The MATLAB R2023a/MATPOWER 5.0 is used to develop a model and analyze using the Newton-Raphson load flow method. The analysis reveals a marginal voltage violation at Bus 13 (below 0.95 p.u.). To enhance stability and efficiency, the network was reconfigured using a hybrid whale algorithm and particle swarm optimization (WAPSO) approach, incorporating new transmission lines (5-8 and 13-14) to improve connectivity and reduce congestion. The reconfiguration reduced active power losses by 29.5% (from 36.013 to 25.371 MW) and reactive power losses by 29.8% (from 301.30 to 211.59 MVAr). The system demonstrated first swing stability, with rotor angles remaining below π/2 (1.5669 rad maximum deviation) and fault clearance within the critical clearing time (0.2 s). Optimized exciter gains and a damping coefficient of 1.5 p.u. ensured effective oscillation suppression and stable generator voltages at 1.05 p.u. The hybrid WAPSO approach proved effective in optimizing voltage and rotor angle stability, enabling the network to meet a 24.086 p.u. load demand while enhancing overall grid reliability.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v15i6.pp6012-6026</dc:identifier><dc:identifier>10.11591/ijece.v15i6.pp6012-6026</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 15 No 6 (2025); 6012</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/40362/18596</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>