Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Microbubble size and rise velocity measurement in dissolved air flotation system

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 16 No. 1 (2026)

DOI
10.11591/ijece.v16i1.pp174-186
ISSN
2722-2578, 2088-8708
Published
2026-02-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Water reuse and resource recovery are priority environmental goals under increasing water scarcity and climate stress. Dissolved air flotation (DAF) is widely applied in municipal, industrial, and decentralized treatment trains because fine microbubbles (MB) enhance solids removal efficiency. Accurate, low-cost characterization of MB size and rise velocity is therefore valuable for process monitoring and optimization. This study develops and validates a smartphone-based, computer-vision pipeline for laboratory-scale DAF systems. After camera calibration and lens un-distortion, each video sequence (235 frames per run) is processed through grayscale conversion, median, Gaussian, and local-Laplacian filtering, gamma correction, and Otsu thresholding, followed by morphological refinement. Circular Hough transform then identifies MB candidates, providing their diameters and centroid locations. These detections are then linked frame-to-frame using a distance-gated nearest-neighbor tracker with dynamic memory allocation to accommodate new MBs under turbulent, bubble-clustering conditions. Rise velocity is computed from interframe centroid displacement and frame interval. The system reliably tracked up to 32 microbubbles simultaneously per video. Across four operating pressure/airflow combinations, mean MB diameters ranged 95.47–216.42 µm and mean rise velocities 9.40×10³–2.76×10⁴ µm/s. The approach is low cost, computationally lightweight, and suitable for rapid MB characterization to support DAF monitoring, optimization, and research.

Collaboration network of the authors

7 authors · 12 co-authorship links · 8 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universidad Católica de Manizales
  • Universidad del Cauca
  • University of La Serena
  • Universidad de la Amazonia
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Yeison Alberto Garcés-GómezUniversidad Católica de Manizales1
Diana Carolina Meneses-CabezasUniversidad Católica de Manizales1
Yuliana Zapata-SernaUniversidad Católica de Manizales1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Microbubble size and rise velocity measurement in dissolved air flotation system</dc:title><dc:creator>Alegría, Jeimmy Adriana Muñoz</dc:creator><dc:creator>Lopera, Jesús Emilio Pinto</dc:creator><dc:creator>Muñoz-España, Elena</dc:creator><dc:creator>Flórez-Marulanda, Juan Fernando</dc:creator><dc:description>&lt;jats:p&gt;Water reuse and resource recovery are priority environmental goals under increasing water scarcity and climate stress. Dissolved air flotation (DAF) is widely applied in municipal, industrial, and decentralized treatment trains because fine microbubbles (MB) enhance solids removal efficiency. Accurate, low-cost characterization of MB size and rise velocity is therefore valuable for process monitoring and optimization. This study develops and validates a smartphone-based, computer-vision pipeline for laboratory-scale DAF systems. After camera calibration and lens un-distortion, each video sequence (235 frames per run) is processed through grayscale conversion, median, Gaussian, and local-Laplacian filtering, gamma correction, and Otsu thresholding, followed by morphological refinement. Circular Hough transform then identifies MB candidates, providing their diameters and centroid locations. These detections are then linked frame-to-frame using a distance-gated nearest-neighbor tracker with dynamic memory allocation to accommodate new MBs under turbulent, bubble-clustering conditions. Rise velocity is computed from interframe centroid displacement and frame interval. The system reliably tracked up to 32 microbubbles simultaneously per video. Across four operating pressure/airflow combinations, mean MB diameters ranged 95.47–216.42 µm and mean rise velocities 9.40×10³–2.76×10⁴ µm/s. The approach is low cost, computationally lightweight, and suitable for rapid MB characterization to support DAF monitoring, optimization, and research.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i1.pp174-186</dc:identifier><dc:identifier>10.11591/ijece.v16i1.pp174-186</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 1 (2026); 174</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/38486/18619</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>