Flashover of a polluted high voltage insulator under electric field distribution

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 16 No. 3 (2026)

DOI
10.11591/ijece.v16i3.pp1097-1106
ISSN
2722-2578, 2088-8708
Published
2026-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

This study investigates the effect of surface pollution on a single-unit 11 kV glass suspension insulator using two-dimensional (2D) axisymmetric simulations in COMSOL Multiphysics. The developed model incorporates the electrical properties of glass, cement, steel electrodes, surrounding air, and a uniform pollution layer, with an applied AC voltage of 11 kV under quasi-static conditions. Simulation results demonstrate pronounced electric field intensification in the polluted configuration, particularly at the air–glass–cap triple junction region, where localized electrical stress is significantly higher compared to the clean condition. While the clean insulator operates within IEC 60383 recommended limits, the polluted model exhibits elevated peak electric field magnitudes, indicating increased flashover vulnerability. The findings highlight the strong influence of surface contamination, material permittivity, and geometric configuration on electric field distribution along the creepage path. This study establishes a reliable and computationally efficient predictive framework for optimizing insulator design, improving maintenance strategies, and enhancing the long-term reliability of high-voltage transmission systems, especially in pollution-prone environments.

Collaboration network of the authors

5 authors · 10 co-authorship links · 5 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Tenaga Nasional
  • Universiti Malaysia Perlis
  • Florida State University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Flashover of a polluted high voltage insulator under electric field distribution</dc:title><dc:creator>Abdullah, Zainab</dc:creator><dc:creator>Zainal Abidin, Izham</dc:creator><dc:creator>Osman, Miszaina</dc:creator><dc:creator>Abd. Rahman, Nurulazmi</dc:creator><dc:creator>Shafiq, Muhammad</dc:creator><dc:description>&lt;jats:p&gt;This study investigates the effect of surface pollution on a single-unit 11 kV glass suspension insulator using two-dimensional (2D) axisymmetric simulations in COMSOL Multiphysics. The developed model incorporates the electrical properties of glass, cement, steel electrodes, surrounding air, and a uniform pollution layer, with an applied AC voltage of 11 kV under quasi-static conditions. Simulation results demonstrate pronounced electric field intensification in the polluted configuration, particularly at the air–glass–cap triple junction region, where localized electrical stress is significantly higher compared to the clean condition. While the clean insulator operates within IEC 60383 recommended limits, the polluted model exhibits elevated peak electric field magnitudes, indicating increased flashover vulnerability. The findings highlight the strong influence of surface contamination, material permittivity, and geometric configuration on electric field distribution along the creepage path. This study establishes a reliable and computationally efficient predictive framework for optimizing insulator design, improving maintenance strategies, and enhancing the long-term reliability of high-voltage transmission systems, especially in pollution-prone environments.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i3.pp1097-1106</dc:identifier><dc:identifier>10.11591/ijece.v16i3.pp1097-1106</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 3 (2026); 1097</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/38076/18736</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>