Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Designing self-healing database fabrics for real-time payment rails

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 16 No. 3 (2026)

DOI
10.11591/ijece.v16i3.pp1360-1368
ISSN
2722-2578, 2088-8708
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Real-time payment platforms operating at scale face an unforgiving operational reality: even brief outages translate directly into failed transactions, regulatory exposure, and eroded customer trust. Database replication and failover automation have matured considerably over the past two decades, yet a troubling blind spot remains. Recovery frameworks built for general-purpose distributed systems were never designed with settlement finality in mind, and that design omission leaves payment operators exposed to split-brain scenarios that generic high-availability tooling cannot reliably prevent. This paper addresses that omission head-on through a self-healing database fabric purpose-built for payment rail environments. The proposed autonomous resilience fabric architecture (ARFA) operates across three coordinated layers: a continuous monitoring layer that harvests telemetry from compute, storage, and network subsystems; a decision layer that fuses rule-based heuristics with an ensemble of isolation forests, recurrent neural networks, and gradient boosting classifiers to separate genuine fault conditions from transient noise; and a deterministic action layer that executes recovery procedures anchored to explicit settlement finality constraints. In fault injection trials covering node crashes, network partitions, replication lag, and performance degradation, the architecture cut average recovery times by 88% against manual baselines, restoring service in roughly 8 seconds rather than the 180 seconds that human-driven remediation typically requires. False positive rates held below 2% across all failure categories, and the system achieved a 98% recovery success rate. Taken together, these results make a practical case that autonomous resilience and regulatory compliance reinforce rather than conflict with each other when the regulatory constraints are designed in from the start.

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 22 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Designing self-healing database fabrics for real-time payment rails</dc:title><dc:creator>Gollapudi, Raghu</dc:creator><dc:description>&lt;jats:p&gt;Real-time payment platforms operating at scale face an unforgiving operational reality: even brief outages translate directly into failed transactions, regulatory exposure, and eroded customer trust. Database replication and failover automation have matured considerably over the past two decades, yet a troubling blind spot remains. Recovery frameworks built for general-purpose distributed systems were never designed with settlement finality in mind, and that design omission leaves payment operators exposed to split-brain scenarios that generic high-availability tooling cannot reliably prevent. This paper addresses that omission head-on through a self-healing database fabric purpose-built for payment rail environments. The proposed autonomous resilience fabric architecture (ARFA) operates across three coordinated layers: a continuous monitoring layer that harvests telemetry from compute, storage, and network subsystems; a decision layer that fuses rule-based heuristics with an ensemble of isolation forests, recurrent neural networks, and gradient boosting classifiers to separate genuine fault conditions from transient noise; and a deterministic action layer that executes recovery procedures anchored to explicit settlement finality constraints. In fault injection trials covering node crashes, network partitions, replication lag, and performance degradation, the architecture cut average recovery times by 88% against manual baselines, restoring service in roughly 8 seconds rather than the 180 seconds that human-driven remediation typically requires. False positive rates held below 2% across all failure categories, and the system achieved a 98% recovery success rate. Taken together, these results make a practical case that autonomous resilience and regulatory compliance reinforce rather than conflict with each other when the regulatory constraints are designed in from the start.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i3.pp1360-1368</dc:identifier><dc:identifier>10.11591/ijece.v16i3.pp1360-1368</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 3 (2026); 1360</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/41765/18755</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>