The shift from reactive to proactive healthcare has accelerated the development of flexible, comfortable, and energy-efficient wearable health monitoring systems. This study addresses a critical technological gap: the inherent trade-off between the mechanical flexibility of organic thin-film transistors (OTFTs) and their limited electrical performance (low charge carrier mobility) compared to rigid silicon-based technologies. To overcome this, we outline the system-level design of a fully configurable analog front-end (AFE) utilizing OTFTs for precise electrocardiogram (ECG) measurement. A theoretical transfer-function-based co-design approach is used to balance gain, noise rejection, and power efficiency via high-fidelity MATLAB/Simulink continuous-time simulations. Simulation results demonstrate that the proposed AFE achieves a 40 dB gain, a precise diagnostic bandwidth of 0.5–150 Hz, a common-mode rejection ratio (CMRR) of 65 dB, and an ultra-low power consumption of 33 µW. These metrics strictly align with standard clinical ECG requirements, outperforming current state-of-the-art all-organic architectures primarily in power efficiency. Consequently, the input signal-to-noise ratio (SNR) is significantly enhanced by 24.53 dB (from 8.01 to 32.54 dB). The novelty of this work lies in achieving silicon-like clinical functionality within an all-organic structure at minimal power. This establishes a new benchmark for flexible electronics and paves the way for invisible, skin-like devices for continuous cardiovascular monitoring.

Collaboration network of the authors

3 authors · 2 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Al Mansour University College
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Hanan A. R. AkkarAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Design and characterization of a flexible ultra-low-power analog front-end circuit using organic thin-film transistors for wearable electrocardiogram monitoring</dc:title><dc:creator>Haddad, Suhad Qasim G.</dc:creator><dc:creator>Chlloob, Ali Falih</dc:creator><dc:description>&lt;jats:p&gt;The shift from reactive to proactive healthcare has accelerated the development of flexible, comfortable, and energy-efficient wearable health monitoring systems. This study addresses a critical technological gap: the inherent trade-off between the mechanical flexibility of organic thin-film transistors (OTFTs) and their limited electrical performance (low charge carrier mobility) compared to rigid silicon-based technologies. To overcome this, we outline the system-level design of a fully configurable analog front-end (AFE) utilizing OTFTs for precise electrocardiogram (ECG) measurement. A theoretical transfer-function-based co-design approach is used to balance gain, noise rejection, and power efficiency via high-fidelity MATLAB/Simulink continuous-time simulations. Simulation results demonstrate that the proposed AFE achieves a 40 dB gain, a precise diagnostic bandwidth of 0.5–150 Hz, a common-mode rejection ratio (CMRR) of 65 dB, and an ultra-low power consumption of 33 µW. These metrics strictly align with standard clinical ECG requirements, outperforming current state-of-the-art all-organic architectures primarily in power efficiency. Consequently, the input signal-to-noise ratio (SNR) is significantly enhanced by 24.53 dB (from 8.01 to 32.54 dB). The novelty of this work lies in achieving silicon-like clinical functionality within an all-organic structure at minimal power. This establishes a new benchmark for flexible electronics and paves the way for invisible, skin-like devices for continuous cardiovascular monitoring.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i4.pp1767-1777</dc:identifier><dc:identifier>10.11591/ijece.v16i4.pp1767-1777</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 4 (2026); 1767</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/41310/18810</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>