Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Performance and quality analysis of brain MRI image transmission over free-space optical communication systems under severe atmospheric conditions

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 16 No. 5 (2026)

DOI
10.11591/ijece.v16i5.pp2526-2536
ISSN
2722-2578, 2088-8708
Published
2026-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-sa/4.0

Abstract

Reliable transfer of brain magnetic resonance imaging (MRI) data over atmospheric free-space optical (FSO) links is a key enabler of telemedicine, yet conventional FSO studies judge link quality by communication metrics such as the bit error rate (BER) alone, which cannot guarantee the structural and contrast fidelity that diagnosis demands. This study proposes a quality-aware FSO transmission framework for brain MRI in which link performance is assessed jointly through BER, peak signal-to-noise ratio (PSNR), and the structural similarity index (SSIM). A physical-layer FSO channel is modelled in OptiSystem 20 and co-simulated with MATLAB R2023b, which performs image serialization, reconstruction, and quality analysis. Thirty axial T2-weighted slices (256×256, 8-bit) from the public IXI dataset are transmitted at 1550 nm over clear-air, rain, and fog channels at 500, 1000, and 2000 m. Adopting conservative diagnostic thresholds of PSNR ≥ 30 dB and SSIM ≥ 0.85, the link is diagnostically usable in clear air at all tested distances (PSNR = 42.1 dB, SSIM = 0.98 at 500 m) and in rain up to 2000 m (PSNR ≥ 31.2 dB), whereas fog degrades quality below the thresholds at every distance, reaching PSNR = 22.7 dB and SSIM = 0.68 at 2000 m. A concatenated forward-error-correction (FEC) scheme is then shown to restore diagnostic quality under fog up to 1000 m, extending the usable fog range, while 2000 m remains infeasible and motivates hybrid FSO/RF operation. The framework provides quantitative deployment limits for FSO-based medical image transport.

Collaboration network of the authors

3 authors · 3 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Middle Technical University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Performance and quality analysis of brain MRI image transmission over free-space optical communication systems under severe atmospheric conditions</dc:title><dc:creator>Zghair, Entidhar Mhawes</dc:creator><dc:creator>Hashem, Seham</dc:creator><dc:creator>Hammadi, Ali</dc:creator><dc:description>&lt;jats:p&gt;Reliable transfer of brain magnetic resonance imaging (MRI) data over atmospheric free-space optical (FSO) links is a key enabler of telemedicine, yet conventional FSO studies judge link quality by communication metrics such as the bit error rate (BER) alone, which cannot guarantee the structural and contrast fidelity that diagnosis demands. This study proposes a quality-aware FSO transmission framework for brain MRI in which link performance is assessed jointly through BER, peak signal-to-noise ratio (PSNR), and the structural similarity index (SSIM). A physical-layer FSO channel is modelled in OptiSystem 20 and co-simulated with MATLAB R2023b, which performs image serialization, reconstruction, and quality analysis. Thirty axial T2-weighted slices (256×256, 8-bit) from the public IXI dataset are transmitted at 1550 nm over clear-air, rain, and fog channels at 500, 1000, and 2000 m. Adopting conservative diagnostic thresholds of PSNR ≥ 30 dB and SSIM ≥ 0.85, the link is diagnostically usable in clear air at all tested distances (PSNR = 42.1 dB, SSIM = 0.98 at 500 m) and in rain up to 2000 m (PSNR ≥ 31.2 dB), whereas fog degrades quality below the thresholds at every distance, reaching PSNR = 22.7 dB and SSIM = 0.68 at 2000 m. A concatenated forward-error-correction (FEC) scheme is then shown to restore diagnostic quality under fog up to 1000 m, extending the usable fog range, while 2000 m remains infeasible and motivates hybrid FSO/RF operation. The framework provides quantitative deployment limits for FSO-based medical image transport.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2026-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v16i5.pp2526-2536</dc:identifier><dc:identifier>10.11591/ijece.v16i5.pp2526-2536</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 16 No 5 (2026); 2526</dc:source><dc:source>2722-2578</dc:source><dc:source>2088-8708</dc:source><dc:relation>https://ijece.iaescore.com/index.php/IJECE/article/viewFile/42550/18877</dc:relation><dc:rights>http://creativecommons.org/licenses/by-sa/4.0</dc:rights></oai_dc:dc>