Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Diagnostic Performance of Afternoon Urine Osmolality to Assess Optimal Hydration Status in an Adult Healthy Population

ACTA MEDICA INDONESIANA · Vol. 49 No. 2 (2017)

ISSN
2338-2732, 0125-9326
Terbit
2017-08-08
Penerbit
The Indonesian Society of Internal Medicine
Bahasa
eng

Abstrak

Background: optimal hydration represents adequate total daily fluid intake to compensate for daily water losses, ensure adequate urine output to reduce the risk of urolithiasis and renal function decline, and also avoid the production of arginine vasopressin (AVP). Twenty-four-hour urine osmolality has been used to assess hydration status, but it is challenging because of the possibility of spilling urine and limitation of daily activities. This study is aimed to determine the performance of the afternoon urine osmolality to assess the optimal hydration status compared with 24-hour urine osmolality. Methods: a cross sectional study was conducted on healthy employees aged 18-59 years at Universitas Indonesia Medical Faculty/Cipto Mangunkusumo Hospital, with consecutive sampling method. The ROC curve was analyzed to obtain the optimal cut off point and the accuracy of the afternoon urine osmolality in assessing the optimal hydration status. Results: between August-September 2016 there were 120 subjects (73.8% female, median age 32 years) who met the study criteria with a median 24-hour urine osmolality 463.5 (95% CI, 136-1427) mOsm/kg H2O and median afternoon urine osmolality 513 (95% CI, 73-1267). We found moderate correlation (r=0.59; p<0.001) between afternoon urine osmolality and a 24-hour urine osmolality. Using ROC curve, the AUC value was 0.792 (95% CI, 0.708-0.875) with the cut off 528 mOsm/kg H2O. To assess the optimal hydration status, the afternoon urine osmolality had the sensitivity of 0.7 (95% CI, 0.585-0.795) and the specificity of 0.76 (95% CI, 0.626-0.857), Likelihood Ratio (LR) (+) 2.917 (95% CI, 1.74-4.889) and LR (-) 0.395 (95% CI, 0.267-0.583). Conclusion: afternoon urine osmolality can be used as a diagnostic tool to assess the optimal hydration status in healthy population with cut off 528 mOsm/kg H2O, sensitivity of 0.7, and specificity of 0.76.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 245 tautan kepenulisan bersama · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Agama Islam Negeri Bone
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti SetiatiAfiliasi tidak diketahui13
Idrus AlwiAfiliasi tidak diketahui6
Noto DwimartutieAfiliasi tidak diketahui5
Evy YunihastutiAfiliasi tidak diketahui5
Rudi PutrantoAfiliasi tidak diketahui4
Roza MulyanaAfiliasi tidak diketahui4
Eka Dian SafitriAfiliasi tidak diketahui4
Rahmi IstantiAfiliasi tidak diketahui4
Eka GinanjarAfiliasi tidak diketahui4
Hamzah ShatriAfiliasi tidak diketahui4
Pringgodigdo NugrohoAfiliasi tidak diketahui4
Suzanna ImmanuelAfiliasi tidak diketahui3
Aida LydiaAfiliasi tidak diketahui3
Taufik IndrajayaAfiliasi tidak diketahui3
Imam SubektiAfiliasi tidak diketahui3
Respati W RanakusumaAfiliasi tidak diketahui3
Siti Rizny F SaldiAfiliasi tidak diketahui3
Jessica MarsigitAfiliasi tidak diketahui3
Suhendro SuwartoAfiliasi tidak diketahui3
Sri SunartiAfiliasi tidak diketahui3
Rensa RensaAfiliasi tidak diketahui3
Muhammad Khifzhon AzwarAfiliasi tidak diketahui3
Fatichati BudiningsihAfiliasi tidak diketahui3
Lazuardhi DwipaAfiliasi tidak diketahui3
Agus SudarsoAfiliasi tidak diketahui3
Andhika RachmanAfiliasi tidak diketahui3
Nafrialdi NafrialdiAfiliasi tidak diketahui3
Ika P WijayaAfiliasi tidak diketahui2
Sally A NasutionAfiliasi tidak diketahui2
Birry KarimAfiliasi tidak diketahui2
Iris RengganisAfiliasi tidak diketahui2
Muhammad YaminInstitut Agama Islam Negeri Bone2
Juferdy KurniawanAfiliasi tidak diketahui2
Muhammad K AzwarAfiliasi tidak diketahui2
Erni J NelwanAfiliasi tidak diketahui2
Sally Aman NasutionAfiliasi tidak diketahui2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://www.actamedindones.org/index.php/ijim/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Diagnostic Performance of Afternoon Urine Osmolality  to Assess Optimal Hydration Status in an Adult Healthy Population</dc:title>
	<dc:creator>Hustrini, Ni Made</dc:creator>
	<dc:creator>Siregar, Parlindungan</dc:creator>
	<dc:creator>Nainggolan, Ginova</dc:creator>
	<dc:creator>Harimurti, Kuntjoro</dc:creator>
	<dc:subject xml:lang="en-US">afternoon urine osmolality</dc:subject>
	<dc:subject xml:lang="en-US">optimal hydration</dc:subject>
	<dc:description xml:lang="en-US">Background: optimal hydration represents adequate total daily fluid intake to compensate for daily water losses, ensure adequate urine output to reduce the risk of urolithiasis and renal function decline, and also avoid the production of arginine vasopressin (AVP). Twenty-four-hour urine osmolality has been used to assess hydration status, but it is challenging because of the possibility of spilling urine and limitation of daily activities. This study is aimed to determine the performance of the afternoon urine osmolality to assess the optimal hydration status compared with 24-hour urine osmolality. Methods: a cross sectional study was conducted on healthy employees aged 18-59 years at Universitas Indonesia Medical Faculty/Cipto Mangunkusumo Hospital, with consecutive sampling method. The ROC curve was analyzed to obtain the optimal cut off point and the accuracy of the afternoon urine osmolality in assessing the optimal hydration status. Results: between August-September 2016 there were 120 subjects (73.8% female, median age 32 years) who met the study criteria with a median 24-hour urine osmolality 463.5 (95% CI, 136-1427) mOsm/kg H2O and median afternoon urine osmolality 513 (95% CI, 73-1267). We found moderate correlation (r=0.59; p&amp;lt;0.001) between afternoon urine osmolality and a 24-hour urine osmolality. Using ROC curve, the AUC value was 0.792 (95% CI, 0.708-0.875) with the cut off 528 mOsm/kg H2O. To assess the optimal hydration status, the afternoon urine osmolality had the sensitivity of 0.7 (95% CI, 0.585-0.795) and the specificity of 0.76 (95% CI, 0.626-0.857), Likelihood Ratio (LR) (+) 2.917 (95% CI, 1.74-4.889) and LR (-) 0.395 (95% CI, 0.267-0.583). Conclusion: afternoon urine osmolality can be used as a diagnostic tool to assess the optimal hydration status in healthy population with cut off 528 mOsm/kg H2O, sensitivity of 0.7, and specificity of 0.76.</dc:description>
	<dc:publisher xml:lang="en-US">The Indonesian Society of Internal Medicine</dc:publisher>
	<dc:date>2017-08-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://www.actamedindones.org/index.php/ijim/article/view/295</dc:identifier>
	<dc:source xml:lang="en-US">Acta Medica Indonesiana; Vol. 49 No. 2 (2017): Acta Medica Indonesiana; 112</dc:source>
	<dc:source>2338-2732</dc:source>
	<dc:source>0125-9326</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://www.actamedindones.org/index.php/ijim/article/view/295/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Acta Medica Indonesiana</dc:rights>
</oai_dc:dc>