Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Need for a New Cut-off Value to Increase Diagnostic Performance of Bioelectrical Impedance Analysis Compared with Dual-Energy X-ray Absorptiometry to Measure Muscle Mass in Indonesian Elderly

ACTA MEDICA INDONESIANA · Vol. 51 No. 2 (2019)

ISSN
2338-2732, 0125-9326
Terbit
2019-08-05
Penerbit
The Indonesian Society of Internal Medicine
Bahasa
eng

Abstrak

Background: the use of bioelectrical impedance analysis (BIA) is affected by the population setting, the type of BIA, and the cut-off point being used. The aim of this study was to determine the diagnostic performance of BIA to measure muscle mass in Indonesian elderly outpatients aged 60 years or more. Methods: a cross-sectional study was conducted at the Geriatric Clinic of Cipto Mangunkusumo Hospital from April to June 2018. The muscle mass was measured using BIA Tanita MC-780MA (Tokyo, Japan) with dual-energy x-ray absorptiometry (DXA) as the reference test. Analysis on the cut-off point was performed based on the Asian Working Group of Sarcopenia (AWGS) criteria and the new cut-off point. Results: from 120 subjects, 74 were female (61.7%). The diagnostic performance of BIA based on AWGS criteria only showed sensitivity and specificity of 79.2% and 66.7%. The diagnostic performance of BIA based on the new cut-off point showed sensitivity and specificity of 75% and 92.7%. The new cut-off point using BIA was found to be <6.9 kg/m2 in males (sensitivity 70.6%; specificity 82.8%) and <5 kg/m2 in females (sensitivity 85.7%; specificity 97%). Conclusion: the diagnostic performance of BIA Tanita MC-780MA (Tokyo, Japan) was good to measure muscle mass in Indonesian elderly outpatients using a new cut-off point of <6.9 kg/m2 for males and <5 kg/m2 for females.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 77 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti SetiatiAfiliasi tidak diketahui7
Juferdy KurniawanAfiliasi tidak diketahui3
Purwita Wijaya LaksmiAfiliasi tidak diketahui3
Mienche MiencheAfiliasi tidak diketahui3
Euphemia SetoAfiliasi tidak diketahui1
Tirza Z TaminAfiliasi tidak diketahui1
Ika P WijayaAfiliasi tidak diketahui1
Benedicta M SuwitaAfiliasi tidak diketahui1
Rudy HidayatAfiliasi tidak diketahui1
Harry IsbagioAfiliasi tidak diketahui1
Andri M.T. LubisAfiliasi tidak diketahui1
Carles SiagianAfiliasi tidak diketahui1
Erick WonggokusumaAfiliasi tidak diketahui1
Aldo F MarsetyoAfiliasi tidak diketahui1
Nur RiviatiAfiliasi tidak diketahui1
Murdani AbdullahAfiliasi tidak diketahui1
Ikhwan RinaldiAfiliasi tidak diketahui1
Rensa RensaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://www.actamedindones.org/index.php/ijim/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Need for a New Cut-off Value to Increase Diagnostic Performance of Bioelectrical Impedance Analysis Compared with Dual-Energy X-ray Absorptiometry to Measure Muscle Mass in Indonesian Elderly</dc:title>
	<dc:creator>Laksmi, Purwita W</dc:creator>
	<dc:creator>Sukma, Fragma Ady</dc:creator>
	<dc:creator>Setyohadi, Bambang</dc:creator>
	<dc:creator>Nugroho, P</dc:creator>
	<dc:creator>Ariane, A</dc:creator>
	<dc:creator>Tirtarahardja, Gunawan</dc:creator>
	<dc:subject xml:lang="en-US">BIA Tanita MC-780MA</dc:subject>
	<dc:subject xml:lang="en-US">elderly</dc:subject>
	<dc:subject xml:lang="en-US">Indonesia</dc:subject>
	<dc:subject xml:lang="en-US">muscle mass</dc:subject>
	<dc:subject xml:lang="en-US">sarcopenia</dc:subject>
	<dc:description xml:lang="en-US">Background: the use of bioelectrical impedance analysis (BIA) is affected by the population setting, the type of BIA, and the cut-off point being used. The aim of this study was to determine the diagnostic performance of BIA to measure muscle mass in Indonesian elderly outpatients aged 60 years or more. Methods: a cross-sectional study was conducted at the Geriatric Clinic of Cipto Mangunkusumo Hospital from April to June 2018. The muscle mass was measured using BIA Tanita MC-780MA (Tokyo, Japan) with dual-energy x-ray absorptiometry (DXA) as the reference test. Analysis on the cut-off point was performed based on the Asian Working Group of Sarcopenia (AWGS) criteria and the new cut-off point. Results: from 120 subjects, 74 were female (61.7%). The diagnostic performance of BIA based on AWGS criteria only showed sensitivity and specificity of 79.2% and 66.7%. The diagnostic performance of BIA based on the new cut-off point showed sensitivity and specificity of 75% and 92.7%. The new cut-off point using BIA was found to be &amp;lt;6.9 kg/m2 in males (sensitivity 70.6%; specificity 82.8%) and &amp;lt;5 kg/m2 in females (sensitivity 85.7%; specificity 97%). Conclusion: the diagnostic performance of BIA Tanita MC-780MA (Tokyo, Japan) was good to measure muscle mass in Indonesian elderly outpatients using a new cut-off point of &amp;lt;6.9 kg/m2 for males and &amp;lt;5 kg/m2 for females.</dc:description>
	<dc:publisher xml:lang="en-US">The Indonesian Society of Internal Medicine</dc:publisher>
	<dc:date>2019-08-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://www.actamedindones.org/index.php/ijim/article/view/977</dc:identifier>
	<dc:source xml:lang="en-US">Acta Medica Indonesiana; Vol. 51 No. 2 (2019): Acta Medica Indonesiana; 95</dc:source>
	<dc:source>2338-2732</dc:source>
	<dc:source>0125-9326</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://www.actamedindones.org/index.php/ijim/article/view/977/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Acta Medica Indonesiana</dc:rights>
</oai_dc:dc>