Jurnal
SINTA 1
Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series
ACTA MEDICA INDONESIANA · Vol. 56 No. 2 (2024)
ISSN 2338-2732, 0125-9326
Terbit 2024-07-16
Penerbit The Indonesian Society of Internal Medicine
Bahasa eng
Abstrak
Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center.
Jaringan kolaborasi para penulis
17 penulis ·
42 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
State University of Semarang Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://www.actamedindones.org/index.php/ijim/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series</dc:title>
<dc:creator>Gunawan, Evan Jim</dc:creator>
<dc:creator>Johan, Johan</dc:creator>
<dc:creator>Munawar, Dian Andina</dc:creator>
<dc:creator>Munawar, Dian Larasati</dc:creator>
<dc:creator>Hartono, Beny</dc:creator>
<dc:creator>Munawar, Muhammad</dc:creator>
<dc:subject xml:lang="en-US">Left bundle pacing</dc:subject>
<dc:subject xml:lang="en-US">sick sinus syndrome</dc:subject>
<dc:subject xml:lang="en-US">pacemaker</dc:subject>
<dc:subject xml:lang="en-US">Cardiology</dc:subject>
<dc:description xml:lang="en-US">Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center. </dc:description>
<dc:publisher xml:lang="en-US">The Indonesian Society of Internal Medicine</dc:publisher>
<dc:date>2024-07-16</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>http://www.actamedindones.org/index.php/ijim/article/view/2449</dc:identifier>
<dc:source xml:lang="en-US">Acta Medica Indonesiana; Vol. 56 No. 2 (2024): Acta Medica Indonesiana; 227</dc:source>
<dc:source>2338-2732</dc:source>
<dc:source>0125-9326</dc:source>
<dc:language>eng</dc:language>
<dc:relation>http://www.actamedindones.org/index.php/ijim/article/view/2449/pdf</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2024 Evan Jim Gunawan, Johan Senihardja, Dian Andina Munawar, Beny Hartono, Muhammad Munawar, Dian Larasati Munawar</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Belum diperiksa
Crossref
Tidak ditemukan
Jumlah menurut tiap indeks pada 9 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
Sitasi artikel ini
APA 7
Gunawan, E. J., Johan, J., Munawar, D. A., Munawar, D. L., Hartono, B., & Munawar, M. (2024). Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series. ACTA MEDICA INDONESIANA, 56(2). http://www.actamedindones.org/index.php/ijim/article/view/2449
Salin
IEEE
E. J. Gunawan, J. Johan, D. A. Munawar, D. L. Munawar, B. Hartono, and M. Munawar, “Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series,” ACTA MEDICA INDONESIANA, vol. 56, no. 2, 2024.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.