Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series

ACTA MEDICA INDONESIANA · Vol. 56 No. 2 (2024)

ISSN
2338-2732, 0125-9326
Terbit
2024-07-16
Penerbit
The Indonesian Society of Internal Medicine
Bahasa
eng

Abstrak

Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 42 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad FadilAfiliasi tidak diketahui3
Fadhil Pratama ApriansyahAfiliasi tidak diketahui3
Darwin IndraAfiliasi tidak diketahui3
Noerlina NoerlinaAfiliasi tidak diketahui1
Yuliana YoswaraAfiliasi tidak diketahui1
Fergyanto E GunawanAfiliasi tidak diketahui1
Rano Kartono RahimAfiliasi tidak diketahui1
Mohammad HamsalAfiliasi tidak diketahui1
Bunyamin BunyaminState University of Semarang1
Sintha WahjusaputriAfiliasi tidak diketahui1
Tashia Indah NastitiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://www.actamedindones.org/index.php/ijim/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Early Experience of Left Bundle Branch Pacing with Lumenless Lead in a Single Center: A Case Series</dc:title>
	<dc:creator>Gunawan, Evan Jim</dc:creator>
	<dc:creator>Johan, Johan</dc:creator>
	<dc:creator>Munawar, Dian Andina</dc:creator>
	<dc:creator>Munawar, Dian Larasati</dc:creator>
	<dc:creator>Hartono, Beny</dc:creator>
	<dc:creator>Munawar, Muhammad</dc:creator>
	<dc:subject xml:lang="en-US">Left bundle pacing</dc:subject>
	<dc:subject xml:lang="en-US">sick sinus syndrome</dc:subject>
	<dc:subject xml:lang="en-US">pacemaker</dc:subject>
	<dc:subject xml:lang="en-US">Cardiology</dc:subject>
	<dc:description xml:lang="en-US">Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold  (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center. </dc:description>
	<dc:publisher xml:lang="en-US">The Indonesian Society of Internal Medicine</dc:publisher>
	<dc:date>2024-07-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://www.actamedindones.org/index.php/ijim/article/view/2449</dc:identifier>
	<dc:source xml:lang="en-US">Acta Medica Indonesiana; Vol. 56 No. 2 (2024): Acta Medica Indonesiana; 227</dc:source>
	<dc:source>2338-2732</dc:source>
	<dc:source>0125-9326</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://www.actamedindones.org/index.php/ijim/article/view/2449/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Evan Jim Gunawan, Johan Senihardja, Dian Andina Munawar, Beny Hartono, Muhammad Munawar, Dian Larasati Munawar</dc:rights>
</oai_dc:dc>