Akses terbuka
Jurnal
SINTA 1
Successful Conservative Management of Right Ventricular Perforation Caused by Temporary Pacemaker Placement during Complex Percutaneous Coronary Intervention: A Case Report
ACTA MEDICA INDONESIANA · Vol. 58 No. 2 (2026)
ISSN 2338-2732, 0125-9326
Terbit 2026-07-03
Penerbit The Indonesian Society of Internal Medicine
Bahasa eng
Abstrak
Cardiac tamponade is a critical condition that can result from complications during invasive cardiac procedures. This case report describes a 67-year-old male who developed right ventricular perforation leading to cardiac tamponade following elective complex percutaneous coronary intervention with rotational atherectomy and temporary pacemaker placement. By performing emergent pericardiocentesis and using a pigtail catheter with sustained negative pressure, we successfully managed a massive pericardial effusion of 2,600 cc. The patient stabilized without requiring surgical intervention, demonstrating favorable outcomes. This case underscores the importance of timely recognition and personalized management strategies in the conservative treatment of cardiac tamponade secondary to right ventricular perforation.
Jaringan kolaborasi para penulis
9 penulis ·
27 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://www.actamedindones.org/index.php/ijim/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Successful Conservative Management of Right Ventricular Perforation Caused by Temporary Pacemaker Placement during Complex Percutaneous Coronary Intervention: A Case Report</dc:title>
<dc:creator>Apriansyah, Fadhil Pratama</dc:creator>
<dc:creator>Munawar, Muhammad</dc:creator>
<dc:creator>Munawar, Dian Larasati</dc:creator>
<dc:creator>Hartono, Beny</dc:creator>
<dc:creator>Fadil, Muhammad</dc:creator>
<dc:creator>Indra, Darwin</dc:creator>
<dc:subject xml:lang="en-US">cardiac tamponade</dc:subject>
<dc:subject xml:lang="en-US">right ventricular perforation</dc:subject>
<dc:subject xml:lang="en-US">temporary pacemaker</dc:subject>
<dc:subject xml:lang="en-US">percutaneous coronary intervention</dc:subject>
<dc:subject xml:lang="en-US">rotational atherectomy</dc:subject>
<dc:description xml:lang="en-US">Cardiac tamponade is a critical condition that can result from complications during invasive cardiac procedures. This case report describes a 67-year-old male who developed right ventricular perforation leading to cardiac tamponade following elective complex percutaneous coronary intervention with rotational atherectomy and temporary pacemaker placement. By performing emergent pericardiocentesis and using a pigtail catheter with sustained negative pressure, we successfully managed a massive pericardial effusion of 2,600 cc. The patient stabilized without requiring surgical intervention, demonstrating favorable outcomes. This case underscores the importance of timely recognition and personalized management strategies in the conservative treatment of cardiac tamponade secondary to right ventricular perforation.</dc:description>
<dc:publisher xml:lang="en-US">The Indonesian Society of Internal Medicine</dc:publisher>
<dc:date>2026-07-03</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>http://www.actamedindones.org/index.php/ijim/article/view/3003</dc:identifier>
<dc:source xml:lang="en-US">Acta Medica Indonesiana; Vol. 58 No. 2 (2026): Acta Medica Indonesiana; 264</dc:source>
<dc:source>2338-2732</dc:source>
<dc:source>0125-9326</dc:source>
<dc:language>eng</dc:language>
<dc:relation>http://www.actamedindones.org/index.php/ijim/article/view/3003/873</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Acta Medica Indonesiana</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Belum diperiksa
Crossref
Tidak ditemukan
Jumlah menurut tiap indeks pada 9 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
Sitasi artikel ini
APA 7
Apriansyah, F. P., Munawar, M., Munawar, D. L., Hartono, B., Fadil, M., & Indra, D. (2026). Successful Conservative Management of Right Ventricular Perforation Caused by Temporary Pacemaker Placement during Complex Percutaneous Coronary Intervention: A Case Report. ACTA MEDICA INDONESIANA, 58(2). http://www.actamedindones.org/index.php/ijim/article/view/3003
Salin
IEEE
F. P. Apriansyah, M. Munawar, D. L. Munawar, B. Hartono, M. Fadil, and D. Indra, “Successful Conservative Management of Right Ventricular Perforation Caused by Temporary Pacemaker Placement during Complex Percutaneous Coronary Intervention: A Case Report,” ACTA MEDICA INDONESIANA, vol. 58, no. 2, 2026.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.