Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking

Atom Indonesia · Vol. 52 No. 1 (2026) · hlm. 1–13

DOI
10.55981/aij.2026.1768
ISSN
2356-5322, 0126-1568
Terbit
2026-02-26
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Accurate neutron flux measurement is essential for reactor characterization and utilization. At the RSG-GAS reactor, previous flux measurements relied on the foil activation method. While this method provides high accuracy, it lacks real-time capability due to its requirement for irradiation, post-irradiation cooling, and subsequent gamma spectroscopy for activity assessment. Direct online measurements of thermal neutron flux in the RSG-GAS reactor irradiation positions were performed using a Sub-Miniature Fission Chamber (SMFC) detector, where the flux was determined from the detector's output current proportional to fission events. This approach offers a viable alternative to the conventional foil activation technique by eliminating its time-consuming process and multiple uncertainty sources. After applying a correction factor obtained from gold foil activation reference measurements and the combined measurement uncertainty was quantified as ± 4.0%, results showed an axial flux distribution peaking at 200 mm height from the bottom of the core with maximum values of 4.997 x 1012 ± 0.199 x 1012 n/cm².s at central iradiation position (CIP E7), 6.212 x 1012 ± 0.248 x 1012 n/cm².s at iradiation position (IP B6), and 2.096 x 1012 ± 0.083x1012 n/cm².s at reflector element with plug (BS+ A2) under 200 kW operation. Radial mapping at 600 mm height from the bottom of the core revealed a maximum flux of 1.230 x 1012 ± 0.049 x 1012 n/cm².s at IP (G7). These results demonstrate that the Sub-Miniature Fission Chamber (SMFC) enables real-time neutron flux monitoring and provides a viable alternative to the conventional foil activation technique.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 28 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • Universitas Gadjah Mada
  • Tokyo City University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Farisy Yogatama SulistyoNational Research and Innovation Agency1
P. H. LiemTokyo City University1
A. A. HakimNational Research and Innovation Agency1
W. LuthfiNational Research and Innovation Agency1
Andang Widi HartoUniversitas Gadjah Mada1
Alif Al MahfudzUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking</dc:title>
	<dc:creator>Gusman, R.</dc:creator>
	<dc:creator>Agung, A.</dc:creator>
	<dc:creator>Subekti, R. M.</dc:creator>
	<dc:creator>Iswahyudi, F. N.</dc:creator>
	<dc:creator>Susanti, F.</dc:creator>
	<dc:creator>Pinem, S.</dc:creator>
	<dc:subject xml:lang="en-US">Sub-miniature fission chamber; Thermal neutron flux; Gold foil activation; RSG-GAS reactor</dc:subject>
	<dc:description xml:lang="en-US">Accurate neutron flux measurement is essential for reactor characterization and utilization. At the RSG-GAS reactor, previous flux measurements relied on the foil activation method. While this method provides high accuracy, it lacks real-time capability due to its requirement for irradiation, post-irradiation cooling, and subsequent gamma spectroscopy for activity assessment. Direct online measurements of thermal neutron flux in the RSG-GAS reactor irradiation positions were performed using a Sub-Miniature Fission Chamber (SMFC) detector, where the flux was determined from the detector's output current proportional to fission events. This approach offers a viable alternative to the conventional foil activation technique by eliminating its time-consuming process and multiple uncertainty sources. After applying a correction factor obtained from gold foil activation reference measurements and the combined measurement uncertainty was quantified as ± 4.0%, results showed an axial flux distribution peaking at 200 mm height from the bottom of the core with maximum values of 4.997 x 1012 ± 0.199 x 1012 n/cm².s at central iradiation position (CIP E7), 6.212 x 1012 ± 0.248 x 1012 n/cm².s at iradiation position (IP B6), and 2.096 x 1012 ± 0.083x1012 n/cm².s at reflector element with plug (BS+ A2) under 200 kW operation. Radial mapping at 600 mm height from the bottom of the core revealed a maximum flux of 1.230 x 1012 ± 0.049 x 1012 n/cm².s at IP (G7). These results demonstrate that the Sub-Miniature Fission Chamber (SMFC) enables real-time neutron flux monitoring and provides a viable alternative to the conventional foil activation technique.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Research and Innovation Agency (BRIN)</dc:contributor>
	<dc:date>2026-02-26</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1768</dc:identifier>
	<dc:identifier>10.55981/aij.2026.1768</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 52, No 1 (2026): APRIL 2026; 1-13</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v52i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1768/1202</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1768/2813</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1768/2898</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1768/2899</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1768/2900</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1768/2901</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>