Akses terbuka
Jurnal
SINTA 1
Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study
Atom Indonesia · Vol. 50 No. 1 (2024) · hlm. 43–48
ISSN 2356-5322, 0126-1568
Terbit 2024-04-01
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
This study aims to verify the weighted Computed Tomography Dose Index (CTDIw) coefficients of 3D rotational angiography (3DRA) procedure using Monte Carlo simulation. The Monte Carlo simulation EGSnrc usercode was employed for 3D dose simulations of the rotational angiography procedure. A virtual phantom resembles the head CTDI phantom was constructed, with a diameter of 16 cm and a density resembling polymethyl methacrylate (1.13 g/cm3). A series of virtual phantoms consisting of 5 images with ionization chamber detectors at the center position, 12 o'clock, 9 o'clock, 6 o'clock, and 3 o'clock were acquired. Simulations were performed with photon sources of 70 and 109 kVp for 200-degree x-ray tube rotation. The field of view was divided into narrow, wide, and full beam with diameters of 1.7 cm; 4.9 cm; and 8.6 cm, respectively. The simulated doses at the ionization chamber were processed into weighting factor for weighted CTDI and compared with direct measurements. The dose ratio between peripheral and center positions for 360° CBCT and 200° 3DRA was 1:1 and 1:3 in this study. The weighting factors for 3DRA were determined as CTDIcenter = ¼ and CTDIperiphery = ¾. The measured average percentage difference of CTDIw between our weighted factor and conventional CTDIw was 1.75 % (-3.99 % to 6.08 %). The x-ray tube position of 3DRA impacted the accuracy of weighting factor of CTDIw, with implications for the proposed weighting factor (Wcenter = ¼ and Wperiphery = ¾) when using a 3DRA machine.
Jaringan kolaborasi para penulis
20 penulis ·
53 tautan kepenulisan bersama
· 11 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Indonesia Prudhoe Hospital Kementerian Kesehatan Republik Indonesia Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study</dc:title>
<dc:creator>Azzi, A.</dc:creator>
<dc:creator>Hidayat, R.</dc:creator>
<dc:creator>Rosa, A.</dc:creator>
<dc:creator>Lubis, L. E.</dc:creator>
<dc:subject xml:lang="en-US">3D rotational angiography; CTDI; Monte Carlo; CBCT</dc:subject>
<dc:description xml:lang="en-US">This study aims to verify the weighted Computed Tomography Dose Index (CTDIw) coefficients of 3D rotational angiography (3DRA) procedure using Monte Carlo simulation. The Monte Carlo simulation EGSnrc usercode was employed for 3D dose simulations of the rotational angiography procedure. A virtual phantom resembles the head CTDI phantom was constructed, with a diameter of 16 cm and a density resembling polymethyl methacrylate (1.13 g/cm3). A series of virtual phantoms consisting of 5 images with ionization chamber detectors at the center position, 12 o'clock, 9 o'clock, 6 o'clock, and 3 o'clock were acquired. Simulations were performed with photon sources of 70 and 109 kVp for 200-degree x-ray tube rotation. The field of view was divided into narrow, wide, and full beam with diameters of 1.7 cm; 4.9 cm; and 8.6 cm, respectively. The simulated doses at the ionization chamber were processed into weighting factor for weighted CTDI and compared with direct measurements. The dose ratio between peripheral and center positions for 360° CBCT and 200° 3DRA was 1:1 and 1:3 in this study. The weighting factors for 3DRA were determined as CTDIcenter = ¼ and CTDIperiphery = ¾. The measured average percentage difference of CTDIw between our weighted factor and conventional CTDIw was 1.75 % (-3.99 % to 6.08 %). The x-ray tube position of 3DRA impacted the accuracy of weighting factor of CTDIw, with implications for the proposed weighting factor (Wcenter = ¼ and Wperiphery = ¾) when using a 3DRA machine.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2024-04-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1307</dc:identifier>
<dc:identifier>10.55981/aij.2024.1307</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; VOL 50, NO 1 (2024): APRIL 2024; 43-48</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v1i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1307/1110</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1307/2392</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1307/2393</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1307/2394</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1307/2395</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1307/2424</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2024 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Azzi, A., Hidayat, R., Rosa, A., & Lubis, L. E. (2024). Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study. Atom Indonesia, 50(1), 43–48. https://doi.org/10.55981/aij.2024.1307
Salin
IEEE
A. Azzi, R. Hidayat, A. Rosa, and L. E. Lubis, “Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study,” Atom Indonesia, vol. 50, no. 1, pp. 43–48, 2024, doi: 10.55981/aij.2024.1307.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.