Reliability Study of the AP1000 Passive Safety System by Fuzzy Approach
Atom Indonesia · Vol. 40 No. 2 (2014) · hlm. 49–56
ISSN 2356-5322, 0126-1568
Terbit 2014-08-27
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
The Westinghouse AP1000 is a new design nuclear power plant which has implemented the concept of passive system. Even though a passive system may be more reliable than an active one, the possibility of the passive system to fail still exists. In line with this possibility, generic database have been used to study the reliability of the AP1000 passive safety system. However, since the used data are not specific to the AP1000, the results of the analysis will not show its real performance. This study proposes a fuzzy reliability approach to overcome this problem. The proposed fuzzy reliability approach utilizes the concept of failure possibility to qualitatively describe basic event likely occurences and membership functions of triangular fuzzy numbers to quantitatively represent qualitative failure possibilities. A case-based experiment on reliability study of the AP1000 passive safety system involved to mitigate a large break loss of collant accident is used to validate the feasibility of the proposed approach. By comparisons, probabilities of basic events generated by the proposed approach are very close to the ones which have been used by previous reliability studies. This can be observed from the small numbers of relative errors, i.e. between 0.004125 and 0.079635. These results confirm that the fuzzy reliability approach offers a more realistic technique to study the reliability of the AP1000 passive safety system without the need to engage to precise probability distributions of its components which are currently unavailable. Received: 08 November 2013; Revised: 28 May 2014; Accepted: 02 June 2014
Jaringan kolaborasi para penulis
9 penulis ·
20 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
National Nuclear Energy Agency of Indonesia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Mulya Juarsa National Nuclear Energy Agency of Indonesia 2
D. Haryanto National Nuclear Energy Agency of Indonesia 1
J.P. Witoko National Nuclear Energy Agency of Indonesia 1
GI Giarno National Nuclear Energy Agency of Indonesia 1
Topan Setiadipura National Nuclear Energy Agency of Indonesia 1
Surip Widodo National Nuclear Energy Agency of Indonesia 1
H.M. Kusuma National Nuclear Energy Agency of Indonesia 1
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Reliability Study of the AP1000 Passive Safety System by Fuzzy Approach</dc:title>
<dc:creator>Purba, J.H.</dc:creator>
<dc:creator>Sony Tjahyani, D.T.</dc:creator>
<dc:subject xml:lang="en-US">Fuzzy reliability approach; Failure possibility; Triangular fuzzy numbers; Passive safety system; AP1000</dc:subject>
<dc:description xml:lang="en-US">The Westinghouse AP1000 is a new design nuclear power plant which has implemented the concept of passive system. Even though a passive system may be more reliable than an active one, the possibility of the passive system to fail still exists. In line with this possibility, generic database have been used to study the reliability of the AP1000 passive safety system. However, since the used data are not specific to the AP1000, the results of the analysis will not show its real performance. This study proposes a fuzzy reliability approach to overcome this problem. The proposed fuzzy reliability approach utilizes the concept of failure possibility to qualitatively describe basic event likely occurences and membership functions of triangular fuzzy numbers to quantitatively represent qualitative failure possibilities. A case-based experiment on reliability study of the AP1000 passive safety system involved to mitigate a large break loss of collant accident is used to validate the feasibility of the proposed approach. By comparisons, probabilities of basic events generated by the proposed approach are very close to the ones which have been used by previous reliability studies. This can be observed from the small numbers of relative errors, i.e. between 0.004125 and 0.079635. These results confirm that the fuzzy reliability approach offers a more realistic technique to study the reliability of the AP1000 passive safety system without the need to engage to precise probability distributions of its components which are currently unavailable. Received: 08 November 2013; Revised: 28 May 2014; Accepted: 02 June 2014</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2014-08-27</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/271</dc:identifier>
<dc:identifier>10.17146/aij.2014.271</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; Vol 40, No 2 (2014): August 2014; 49-56</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.17146/aij.2014.%x</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/271/236</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/271/212</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/271/213</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/271/214</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/271/215</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2016 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Purba, J., & Sony Tjahyani, D. (2014). Reliability Study of the AP1000 Passive Safety System by Fuzzy Approach. Atom Indonesia, 40(2), 49–56. https://doi.org/10.17146/aij.2014.271
Salin
IEEE
J. Purba and D. Sony Tjahyani, “Reliability Study of the AP1000 Passive Safety System by Fuzzy Approach,” Atom Indonesia, vol. 40, no. 2, pp. 49–56, 2014, doi: 10.17146/aij.2014.271.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.