Akses terbuka
Jurnal
SINTA 1
Analysis of Radiation Exposure Level on Linen and Other Objects in Patient Rooms at Nuclear Medicine Installation
Atom Indonesia · Vol. 49 No. 3 (2023) · hlm. 185–192
ISSN 2356-5322, 0126-1568
Terbit 2023-12-02
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
Analysis of radiation contamination levels has been carried out using an Atomtex surveymeter in the patient rooms after thyroid cancer ablation therapy, in the Nuclear Medicine Installation, Abdoel Wahab Sjahranie Hospital. This study aims to measure the level of radiation exposure based on the rate of radiation exposure and radiation contamination of objects in the patient rooms after ablation therapy, and to find out how long linen can be washed since the first measurement. Data collection was carried out once a week, on the same weekday, for five weeks for objects in the patient rooms by using the surveymeter at a fixed distances from the objects’ surfaces. Radiation contamination measurements for linen items were carried out for 3 d by aiming the surveymeter to container containing linen items from certain distances. Based on this study, the level of radiation exposure obtained is categorized as low because the value range is below 10 μSv/h. The radiation contamination for some objects are categorized as low-level exposure because the value is less than 3.7 Bq/cm2. Other objects tend to be in the moderate-level category because the value is more than 3.7 Bq/cm2 and less than 37 Bq/cm2. The values obtained refer to the standard issued by BATAN. It can be concluded that the patient rooms in the Nuclear Medicine Installation of Abdoel Wahab Sjahranie Hospital are safe.
Jaringan kolaborasi para penulis
23 penulis ·
46 tautan kepenulisan bersama
· 6 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mulawarman University Lambung Mangkurat University University of Indonesia Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Analysis of Radiation Exposure Level on Linen and Other Objects in Patient Rooms at Nuclear Medicine Installation</dc:title>
<dc:creator>Putri, A.</dc:creator>
<dc:creator>Zurma, R.</dc:creator>
<dc:creator>Munir, R.</dc:creator>
<dc:creator>Putri, E. R.</dc:creator>
<dc:subject xml:lang="en-US">Radiation contamination; Radiation exposure; Radiation protection; Surveymeter</dc:subject>
<dc:description xml:lang="en-US">Analysis of radiation contamination levels has been carried out using an Atomtex surveymeter in the patient rooms after thyroid cancer ablation therapy, in the Nuclear Medicine Installation, Abdoel Wahab Sjahranie Hospital. This study aims to measure the level of radiation exposure based on the rate of radiation exposure and radiation contamination of objects in the patient rooms after ablation therapy, and to find out how long linen can be washed since the first measurement. Data collection was carried out once a week, on the same weekday, for five weeks for objects in the patient rooms by using the surveymeter at a fixed distances from the objects’ surfaces. Radiation contamination measurements for linen items were carried out for 3 d by aiming the surveymeter to container containing linen items from certain distances. Based on this study, the level of radiation exposure obtained is categorized as low because the value range is below 10 μSv/h. The radiation contamination for some objects are categorized as low-level exposure because the value is less than 3.7 Bq/cm2. Other objects tend to be in the moderate-level category because the value is more than 3.7 Bq/cm2 and less than 37 Bq/cm2. The values obtained refer to the standard issued by BATAN. It can be concluded that the patient rooms in the Nuclear Medicine Installation of Abdoel Wahab Sjahranie Hospital are safe.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2023-12-02</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1291</dc:identifier>
<dc:identifier>10.55981/aij.2023.1291</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; VOL 49, NO 3 (2023): DECEMBER 2023; 185-192</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v49i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1291/1096</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2358</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2359</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2360</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2361</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2362</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1291/2363</dc:relation>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Putri, A., Zurma, R., Munir, R., & Putri, E. R. (2023). Analysis of Radiation Exposure Level on Linen and Other Objects in Patient Rooms at Nuclear Medicine Installation. Atom Indonesia, 49(3), 185–192. https://doi.org/10.55981/aij.2023.1291
Salin
IEEE
A. Putri, R. Zurma, R. Munir, and E. R. Putri, “Analysis of Radiation Exposure Level on Linen and Other Objects in Patient Rooms at Nuclear Medicine Installation,” Atom Indonesia, vol. 49, no. 3, pp. 185–192, 2023, doi: 10.55981/aij.2023.1291.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.