Akses terbuka
Jurnal
SINTA 1
The Dose Distribution from Iridium-192 Source on Cervical Cancer Brachytherapy by Manchester System Using Monte Carlo Simulation
Atom Indonesia · Vol. 47 No. 3 (2021) · hlm. 205–211
ISSN 2356-5322, 0126-1568
Terbit 2021-12-03
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
One treatment for cervical cancer is to use radioactive sources that directly target the cancer cell called brachytherapy. This study is aimed to determine dose distribution at phantom pelvis using the DOSXYZnrc Monte Carlo code. The phantom was derived from a CT scan image of the DICOM-type pelvis with a size of 50 × 50 × 28.8 cm obtained from Santosa Kopo Hospital. The source used was Ir-192, which makes an asymmetrical beam with a size of 0.45 × 0.09 × 0.09 cm. Monte Carlo simulation was performed to determine the dose distribution of the Ir-192 source on cervical cancer CT images based on the Manchester system. The Monte Carlo simulation was divided into two models with distance variations on the applicator. Model A used TPS data with a distance between sources of 0.9 cm, while model B had a distance between sources of 0.5 cm. The distribution of dose resulting from the Monte Carlo simulation was analyzed and compared with TPS data. The results showed that at the range of 50 %, dose distribution in model A reaches the end of 3.9 cm. When compared to the range of 50 % dose distribution at the TPS results that reaches the point of 4 cm, it produces a deviation value of 2.5 %, which is still within the tolerance range. Model A and Model B provide different dose distribution. In model B, it reaches 3.86 cm, resulting in a deviation of 1.02 %, which is still within the tolerance range. The resulting γ-index value for the 50 % dose distribution was 2.26, while the whole area's GPR value was 94.13 %. This indicates a difference in dose distribution between the two models. Therefore, the smaller the distance between the sources, the shorter the dose distribution range with relatively more uniform dose distribution.
Jaringan kolaborasi para penulis
25 penulis ·
73 tautan kepenulisan bersama
· 51 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology Universitas Matana Sunan Kalijaga State Islamic University Yogyakarta Syarif Hidayatullah State Islamic University Jakarta Universitas Prima Nusantara Bukittinggi Diponegoro University California State University, Channel Islands Organisasi lain Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">The Dose Distribution from Iridium-192 Source on Cervical Cancer Brachytherapy by Manchester System Using Monte Carlo Simulation</dc:title>
<dc:creator>Kurniati, F.</dc:creator>
<dc:creator>Krisna, F. P.</dc:creator>
<dc:creator>Junios, J.</dc:creator>
<dc:creator>Haryanto, F.</dc:creator>
<dc:subject xml:lang="en-US">Brachytherapy; CT image; Ir-192 source; Manchester system; Monte carlo simulation</dc:subject>
<dc:description xml:lang="en-US">One treatment for cervical cancer is to use radioactive sources that directly target the cancer cell called brachytherapy. This study is aimed to determine dose distribution at phantom pelvis using the DOSXYZnrc Monte Carlo code. The phantom was derived from a CT scan image of the DICOM-type pelvis with a size of 50 × 50 × 28.8 cm obtained from Santosa Kopo Hospital. The source used was Ir-192, which makes an asymmetrical beam with a size of 0.45 × 0.09 × 0.09 cm. Monte Carlo simulation was performed to determine the dose distribution of the Ir-192 source on cervical cancer CT images based on the Manchester system. The Monte Carlo simulation was divided into two models with distance variations on the applicator. Model A used TPS data with a distance between sources of 0.9 cm, while model B had a distance between sources of 0.5 cm. The distribution of dose resulting from the Monte Carlo simulation was analyzed and compared with TPS data. The results showed that at the range of 50 %, dose distribution in model A reaches the end of 3.9 cm. When compared to the range of 50 % dose distribution at the TPS results that reaches the point of 4 cm, it produces a deviation value of 2.5 %, which is still within the tolerance range. Model A and Model B provide different dose distribution. In model B, it reaches 3.86 cm, resulting in a deviation of 1.02 %, which is still within the tolerance range. The resulting γ-index value for the 50 % dose distribution was 2.26, while the whole area's GPR value was 94.13 %. This indicates a difference in dose distribution between the two models. Therefore, the smaller the distance between the sources, the shorter the dose distribution range with relatively more uniform dose distribution. </dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US">This study was fully supported by Program Penelitian Kolaborasi Indonesia (PPKI) (grant number 020/WCU-ITB/LL/I/2020)</dc:contributor>
<dc:date>2021-12-03</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1102</dc:identifier>
<dc:identifier>10.17146/aij.2021.1102</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; Vol 47, No 3 (2021): December 2021; 205-211</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v47i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1102/996</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1102/1908</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1102/2077</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1102/2078</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1102/2079</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1102/2080</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Kurniati, F., Krisna, F. P., Junios, J., & Haryanto, F. (2021). The Dose Distribution from Iridium-192 Source on Cervical Cancer Brachytherapy by Manchester System Using Monte Carlo Simulation. Atom Indonesia, 47(3), 205–211. https://doi.org/10.17146/aij.2021.1102
Salin
IEEE
F. Kurniati, F. P. Krisna, J. Junios, and F. Haryanto, “The Dose Distribution from Iridium-192 Source on Cervical Cancer Brachytherapy by Manchester System Using Monte Carlo Simulation,” Atom Indonesia, vol. 47, no. 3, pp. 205–211, 2021, doi: 10.17146/aij.2021.1102.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.