Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Occupational and Patient Doses in Interventional Cardiology in Indonesia: A Preliminary Result

Atom Indonesia · Vol. 45 No. 1 (2019) · hlm. 37–41

DOI
10.17146/aij.2019.862
ISSN
2356-5322, 0126-1568
Terbit
2019-04-02
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Interventional cardiology is a branch of cardiology that manages the catheter based treatment of structural heart illnesses. These minimally invasive procedures involve inserting catheters and other devices through superficial arterial and venous access sites. Due to increased reliability and advancing technology, the number and complexity of interventional cardiology procedures haves increased in recent years. The increasing complexity of the procedures, however, require longer fluoroscopic duration, leading to increased exposure time to ionizing radiation for the patient and also for the medical staff since they need to remain close to the patient throughout the procedure. This study attempts to investigate the occupational and patient doses during the course of several interventional cardiology procedures in Indonesia, i.e. CA, PCI, cathscan, PA, PTCA, TACE, PAC and peripheral vascular. Occupational doses were measured by using individually packed three chips of TLD-100 placed in over- and under-thyroid shield used by medical staff, over- and under-apron in waist position, inside a special ‘eye-D’ holder, and inside a ring holder, while patient doses were estimated by using individually packed three TLD-100 chips attached in the x-ray tube. All TLDs were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) Jakarta. The study was performed in three big hospitals in the cities of Jakarta, Yogyakarta and Semarang. The results show that PCI procedure was the most performed one during the course of this study and gave the highest radiation doses to the staff for all type of doses calculated and measured. The maximum effective doses, eye lens doses, extremity doses, thyroid doses and gonad/ovary doses were 0.098 mSv, 0.1967 mSv, 0.7604 mSv, 0.1760 mSv and 0.0990 mSv, respectively. In the case of patient doses, the mean value of DAP for PTCA procedure of 776.76 Gy cm2 was the highest compared with those for other procedures. The results of measurement for occupational doses were in general similar to those reported by other authors, but not for patient doses that was found to be 4-5 times higher. Due to the involving of various parameters during the course of interventional cardiology procedures, it was difficult to establish a correlation between the doses received by medical staff and by the patients.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 38 tautan kepenulisan bersama · 23 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Nuclear Energy Agency of Indonesia
  • National Research and Innovation Agency
  • University of Indonesia
  • University of Malaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
K.Y.P. SandyNational Nuclear Energy Agency of Indonesia11
Heru PrasetioNational Research and Innovation Agency4
Fendi nugrohoNational Research and Innovation Agency1
Okky Agassy FirmansyahNational Nuclear Energy Agency of Indonesia1
Bimo SaputroUniversity of Indonesia1
Adhi Harmoko SaputroUniversity of Indonesia1
Hasan MayditiaNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Occupational and Patient Doses in Interventional Cardiology in Indonesia: A Preliminary Result</dc:title>
	<dc:creator>Hiswara, E.</dc:creator>
	<dc:creator>Ng, K.H.</dc:creator>
	<dc:creator>Sofyan, H.</dc:creator>
	<dc:creator>Kartikasari, D.</dc:creator>
	<dc:creator>Nuraeni, N.</dc:creator>
	<dc:subject xml:lang="en-US">Occupational exposure; Patient exposure; Interventional cardiology; Medical exposure</dc:subject>
	<dc:description xml:lang="en-US">Interventional cardiology is a branch of cardiology that manages the catheter based treatment of structural heart illnesses. These minimally invasive procedures involve inserting catheters and other devices through superficial arterial and venous access sites. Due to increased reliability and advancing technology, the number and complexity of interventional cardiology procedures haves increased in recent years. The increasing complexity of the procedures, however, require longer fluoroscopic duration, leading to increased exposure time to ionizing radiation for the patient and also for the medical staff since they need to remain close to the patient throughout the procedure. This study attempts to investigate the occupational and patient doses during the course of several interventional cardiology procedures in Indonesia, i.e. CA, PCI, cathscan, PA, PTCA, TACE, PAC and peripheral vascular. Occupational doses were measured by using individually packed three chips of TLD-100 placed in over- and under-thyroid shield used by medical staff, over- and under-apron in waist position, inside a special ‘eye-D’ holder, and inside a ring holder, while patient doses were estimated by using individually packed three TLD-100 chips attached in the x-ray tube. All TLDs were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) Jakarta. The study was performed in three big hospitals in the cities of Jakarta, Yogyakarta and Semarang. The results show that PCI procedure was the most performed one during the course of this study and gave the highest radiation doses to the staff for all type of doses calculated and measured. The maximum effective doses, eye lens doses, extremity doses, thyroid doses and gonad/ovary doses were 0.098 mSv, 0.1967 mSv, 0.7604 mSv, 0.1760 mSv and 0.0990 mSv, respectively. In the case of patient doses, the mean value of DAP for PTCA procedure of 776.76 Gy cm2 was the highest compared with those for other procedures. The results of measurement for occupational doses were in general similar to those reported by other authors, but not for patient doses that was found to be 4-5 times higher. Due to the involving of various parameters during the course of interventional cardiology procedures, it was difficult to establish a correlation between the doses received by medical staff and by the patients.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Nuclear Energy Agency (BATAN)</dc:contributor>
	<dc:date>2019-04-02</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/862</dc:identifier>
	<dc:identifier>10.17146/aij.2019.862</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 45, No 1 (2019): April 2019; 37-41</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v45i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/862/678</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1131</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1132</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1217</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1394</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1395</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1396</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/862/1413</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>