Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimization of Electrodeposition Parameters to Increase 99mTc Radioactive Concentration

Atom Indonesia · Vol. 43 No. 1 (2017) · hlm. 27–33

DOI
10.17146/aij.2017.618
ISSN
2356-5322, 0126-1568
Terbit
2017-06-21
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

The use of low activity concentration 99mTc would result in low-quality labeled compound for diagnostic purpose. The low activity concentration of labeled compound will alter biodistribution and lead to false imaging in diagnostic applications. Electrodeposition could be an alternative method for increasing the activity concentration of 99mTc solution. The influence of electrodeposition parameters such as electrolytes, concentration of electrolyte, and voltage and time of deposition were examined to find the optimum condition for electrodeposition. Electrolytes to be evaluated were NaNO2, Na-oxalate, NaOH, and NaCl. Concentration factor is defined by ratio of final against initial concentration of 99mTc. The quality assessment of 99mTc after electrodeposition was conducted by labeling test of methylene diphosphonate (MDP) and 1,4,8,11-tetraaza cyclotetradecyl-1,4,8,11-tetramethylene phosphonic acid (CTMP). The results showed that the addition of NaNO2 electrolyte gave the highest electrodeposition yield in comparison with Na-oxalate, NaOH, and NaCl, while the optimum concentration of electrolytes was 0.67 M. The optimum depostion voltage and duration were 7 V and 90 minutes, respectively. The electrodeposition yield was 96 % under optimized condition with a concentration factor of up to 7.96. In the quality assessment, MDP and CTMP were successfully labeled by concentrated 99mTc to give 99mTc-MDP and 99mTc-CTMP labeled compounds with radiochemical purities of more than 95 %.Received: 2 November 2015; Revised: 14 July 2016; Accepted: 3 October 2016

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 64 tautan kepenulisan bersama · 42 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Nuclear Energy Agency of Indonesia
  • Universitas Jenderal Achmad Yani
  • Bandung Institute of Technology
  • National Research and Innovation Agency
  • Padjadjaran University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Eva Maria WidyasariNational Nuclear Energy Agency of Indonesia1
Maula Eka SriyaniNational Nuclear Energy Agency of Indonesia1
Witri NuraeniNational Nuclear Energy Agency of Indonesia1
Anceu MurniatiUniversitas Jenderal Achmad Yani1
Jasmansyah JasmansyahUniversitas Jenderal Achmad Yani1
Arie HardianUniversitas Jenderal Achmad Yani1
Atiek Rostika NoviyantiPadjadjaran University1
Muhammad RezaBandung Institute of Technology1
Farah Nur FauziyahUniversitas Jenderal Achmad Yani1
Teguh KaryaUniversitas Jenderal Achmad Yani1
Dani Gustaman SyarifNational Research and Innovation Agency1
Kiki Adi KurniaBandung Institute of Technology1
Ismunandar IsmunandarBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimization of Electrodeposition Parameters to Increase 99mTc Radioactive Concentration</dc:title>
	<dc:creator>Febrian, M.B.</dc:creator>
	<dc:creator>Setiadi, Y.</dc:creator>
	<dc:creator>Wibawa, T.H.A.</dc:creator>
	<dc:subject xml:lang="en-US">Electrochemical; Technetium-99m; NaNO2; Radioactive concentration</dc:subject>
	<dc:description xml:lang="en-US">The use of low activity concentration 99mTc would result in low-quality labeled compound for diagnostic purpose. The low activity concentration of labeled compound will alter biodistribution and lead to false imaging in diagnostic applications. Electrodeposition could be an alternative method for increasing the activity concentration of 99mTc solution. The influence of electrodeposition parameters such as electrolytes, concentration of electrolyte, and voltage and time of deposition were examined to find the optimum condition for electrodeposition. Electrolytes to be evaluated were NaNO2, Na-oxalate, NaOH, and NaCl. Concentration factor is defined by ratio of final against initial concentration of 99mTc. The quality assessment of 99mTc after electrodeposition was conducted by labeling test of methylene diphosphonate (MDP) and 1,4,8,11-tetraaza cyclotetradecyl-1,4,8,11-tetramethylene phosphonic acid (CTMP). The results showed that the addition of NaNO2 electrolyte gave the highest electrodeposition yield in comparison with Na-oxalate, NaOH, and NaCl, while the optimum concentration of electrolytes was 0.67 M. The optimum depostion voltage and duration were 7 V and 90 minutes, respectively. The electrodeposition yield was 96 % under optimized condition with a concentration factor of up to 7.96. In the quality assessment, MDP and CTMP were successfully labeled by concentrated 99mTc to give 99mTc-MDP and 99mTc-CTMP labeled compounds with radiochemical purities of more than 95 %.Received: 2 November 2015; Revised: 14 July 2016; Accepted: 3 October 2016</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Nuclear Energy Agency of Indonesia</dc:contributor>
	<dc:date>2017-06-21</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/618</dc:identifier>
	<dc:identifier>10.17146/aij.2017.618</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 43, No 1 (2017): April 2017; 27-33</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v43i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/618/485</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/561</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/562</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/563</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/565</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/566</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/568</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/569</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/570</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/571</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/572</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/618/573</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>