Akses terbuka
Jurnal
SINTA 1
Image Quality Assessment of Hybrid Statistical Iterative Reconstruction (H/SIR) in Comparison to Filtered Back Projection (FBP)
Atom Indonesia · Vol. 52 No. 1 (2026) · hlm. 23–28
ISSN 2356-5322, 0126-1568
Terbit 2026-03-02
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
Hybrid Statistical Iterative Reconstruction (H/SIR) is a method for Computed Tomography (CT) image reconstruction that provides optimal diagnostic images while reducing radiation doses compared to the standard protocol using Filtered Back Projection (FBP). This work aims to assess the image quality metrics; Signal to Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) of Low-Dose Computed Tomography (LDCT) examination with different vendors H/SIR algorithms. Three CT scanners from different manufacturers (Philips, GE, and Siemens) were used in this work. A total of 218 clinical images were analysed. The SNR and CNR of LDCT+H/SIR images were compared with standard protocol combined with FBP. The quantitative assessments were achieved by IndoQCT software. Results showed that H/SIR preserved image quality while radiation dose was minimized.
Jaringan kolaborasi para penulis
8 penulis ·
19 tautan kepenulisan bersama
· 15 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universiti Sains Malaysia Diponegoro University Al-Quds University Hospital Universiti Sains Malaysia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Image Quality Assessment of Hybrid Statistical Iterative Reconstruction (H/SIR) in Comparison to Filtered Back Projection (FBP)</dc:title>
<dc:creator>Arjah, H.</dc:creator>
<dc:creator>Osman, N. D.</dc:creator>
<dc:creator>ALMasri, H.</dc:creator>
<dc:creator>Anam, C.</dc:creator>
<dc:creator>Aziz, M. E.</dc:creator>
<dc:subject xml:lang="en-US">Computed tomography; Low dose; Iterative reconstruction</dc:subject>
<dc:description xml:lang="en-US">Hybrid Statistical Iterative Reconstruction (H/SIR) is a method for Computed Tomography (CT) image reconstruction that provides optimal diagnostic images while reducing radiation doses compared to the standard protocol using Filtered Back Projection (FBP). This work aims to assess the image quality metrics; Signal to Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) of Low-Dose Computed Tomography (LDCT) examination with different vendors H/SIR algorithms. Three CT scanners from different manufacturers (Philips, GE, and Siemens) were used in this work. A total of 218 clinical images were analysed. The SNR and CNR of LDCT+H/SIR images were compared with standard protocol combined with FBP. The quantitative assessments were achieved by IndoQCT software. Results showed that H/SIR preserved image quality while radiation dose was minimized.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-03-02</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1528</dc:identifier>
<dc:identifier>10.55981/aij.2026.1528</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; Vol 52, No 1 (2026): APRIL 2026; 23-28</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v52i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1528/1203</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1528/2904</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1528/2905</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1528/2906</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1528/2907</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Arjah, H., Osman, N. D., ALMasri, H., Anam, C., & Aziz, M. E. (2026). Image Quality Assessment of Hybrid Statistical Iterative Reconstruction (H/SIR) in Comparison to Filtered Back Projection (FBP). Atom Indonesia, 52(1), 23–28. https://doi.org/10.55981/aij.2026.1528
Salin
IEEE
H. Arjah, N. D. Osman, H. ALMasri, C. Anam, and M. E. Aziz, “Image Quality Assessment of Hybrid Statistical Iterative Reconstruction (H/SIR) in Comparison to Filtered Back Projection (FBP),” Atom Indonesia, vol. 52, no. 1, pp. 23–28, 2026, doi: 10.55981/aij.2026.1528.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.