Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital

Atom Indonesia · Vol. 48 No. 2 (2022) · hlm. 159–167

DOI
10.17146/aij.2022.1131
ISSN
2356-5322, 0126-1568
Terbit
2022-08-22
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Institutional diagnostic reference levels are used for quality assurance in radiology departments. The purpose of this study was to establish an institutional diagnostic reference level (DRL) and to provide a practical tool in diagnostic radiology and nuclear medicine. For each type of procedure/examination, it needs at least 20 patients. The patients with regular size (average body size is 65 ± 10 kg for adult patients and 15±15 kg for pediatric patients) were enrolled in this project. The 75 percentile values of doses were used as institutional DRLs. For nuclear medicine, the administered activities was based on the dose of activity to produce a good image. The DRL values were obtained for general radiography, nuclear medicine, mammography, CT examination, and interventional radiography. The DRL's result was compared to national DRL (NDRL) and values in other countries. The DRL values for general radiography in this study are higher compared to NDRL and Japanese study. The administered activities (MBq) for nuclear medicine in this study are higher compared to European Commission but lower when compared to a Japanese study. The DRL values for mammography in this study are higher compared to ARPANSA; however, they are lower than NDRL and UK studies. The DRL values for CT examination in this study are higher compared to Netherland, Canadian, and USA studies but lower than NDRL. The DRL values in interventional radiography (IR) in this study are lower compared to the IAEA study. This finding indicates that it is still necessary to optimize procedures in the future. The established institutional DRL values can be used as a tool for optimization.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 119 tautan kepenulisan bersama · 71 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • Universiti Sains Malaysia
  • University of Indonesia
  • Bandung Institute of Technology
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Pertamina (Indonesia)
  • Ministry of Health
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Geoff DoughertyCalifornia State University, Channel Islands5
Ariij NaufalDiponegoro University3
Freddy HaryantoBandung Institute of Technology2
Annisa Lidia WatiDiponegoro University2
Arrum NitasariDiponegoro University2
S SyarifudinDr. Kariadi Hospital2
Mohd Hanafi AliLincoln University College2
N.P. ViantriDiponegoro University1
Wahyu SetiabudiDiponegoro University1
F. NadzirPertamina (Indonesia)1
Chavied VarunaPertamina (Indonesia)1
Rena WiditaBandung Institute of Technology1
Idam ArifBandung Institute of Technology1
Mohamad Fahdillah RhaniTan Tock Seng Hospital1
S. YaniIPB University1
S. SofiyatunDiponegoro University1
Ummu Mar'atu ZahroDiponegoro University1
Dito Andi RukmanaAfiliasi tidak diketahui1
M. T. SaidinMinistry of Health1
Azhar Abdul RahmanUniversiti Sains Malaysia1
Hanif Haspi HarunMinistry of Health1
Yasmin Md RadziUniversiti Sains Malaysia1
Zunaide KayunGovernment of Malaysia1
Hamza ArjahUniversiti Sains Malaysia1
H. ALMasriAl-Quds University1
Noor Diyana OsmanUniversiti Sains Malaysia1
Mohd Ezane AzizHospital Universiti Sains Malaysia1
Wahyu Setia BudiDiponegoro University1
Eko HidayantoDiponegoro University1
Dewi Angraini InsianoDiponegoro University1
Annisa Tenri MayaAfiliasi tidak diketahui1
Tunggul Drajat MulatomoAfiliasi tidak diketahui1
Riska AmiliaDiponegoro University1
Yanurita DwihapsariInstitut Teknologi Sepuluh Nopember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital</dc:title>
	<dc:creator>Amalia, T.</dc:creator>
	<dc:creator>Zulkarnaien, B.</dc:creator>
	<dc:creator>Anam, C.</dc:creator>
	<dc:creator>Nurcahyo, K.</dc:creator>
	<dc:creator>Tussyadiah, H.</dc:creator>
	<dc:creator>Pradana, D. E.</dc:creator>
	<dc:subject xml:lang="en-US">Diagnostic reference levels; Diagnostic radiology; Optimization; Patient safety</dc:subject>
	<dc:description xml:lang="en-US">Institutional diagnostic reference levels are used for quality assurance in radiology departments. The purpose of this study was to establish an institutional diagnostic reference level (DRL) and to provide a practical tool in diagnostic radiology and nuclear medicine. For each type of procedure/examination, it needs at least 20 patients. The patients with regular size (average body size is 65 ± 10 kg for adult patients and 15±15 kg for pediatric patients) were enrolled in this project. The 75 percentile values of doses were used as institutional DRLs.  For nuclear medicine, the administered activities was based on the dose of activity to produce a good image. The DRL values were obtained for general radiography, nuclear medicine, mammography, CT examination, and interventional radiography. The DRL's result was compared to national DRL (NDRL) and values in other countries. The DRL values for general radiography in this study are higher compared to NDRL and Japanese study. The administered activities (MBq) for nuclear medicine in this study are higher compared to European Commission but lower when compared to a Japanese study. The DRL values for mammography in this study are higher compared to ARPANSA; however, they are lower than NDRL and UK studies. The DRL values for CT examination in this study are higher compared to Netherland, Canadian, and USA studies but lower than NDRL. The DRL values in interventional radiography (IR) in this study are lower compared to the IAEA study. This finding indicates that it is still necessary to optimize procedures in the future. The established institutional DRL values can be used as a tool for optimization.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">Installation of  Radiology and Nuclear Medicine, dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia</dc:contributor>
	<dc:date>2022-08-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1131</dc:identifier>
	<dc:identifier>10.17146/aij.2022.1131</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 48, No 2 (2022): August 2022; 159-167</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v48i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1131/1028</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1131/1955</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>