Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Dosimetric Evaluation of Very High Energy Electron (VHEE) Beams in the Male Pelvic Region Using Geant4/TOPAS

Atom Indonesia · Vol. 51 No. 2 (2025) · hlm. 109–117

DOI
10.55981/aij.2025.1599
ISSN
2356-5322, 0126-1568
Terbit
2025-05-16
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

The CLEAR (CERN Linear Electron Accelerator for Research) facility has significantly advanced high-energy electron radiotherapy, particularly for treating deep-seated tumors. However, achieving precise and accessible treatment delivery while minimizing damage to surrounding healthy tissues remains challenging. Very High Energy Electrons Beam (VHEE) offer notable potential due to their deep penetration capabilities. However, their nearly uniform dose distribution raises concerns about unintended exposure to healthy tissues. A key innovation in this field is the use of focused VHEE beams, which deliver a concentrated dose to a small defined area at a high dose rate, potentially enhancing treatment precision. This study evaluates the dosimetric characteristics of focused VHEE beams compared to collimated beams using GEANT4/TOPAS Monte Carlo simulations. A beamline with two quadrupole magnet triplets was designed to focus VHEE beams on a water phantom, simulating clinical conditions. The findings show that focused VHEE beams increased the dose to the prostate by 5.24 % while significantly reducing the dose to adjacent organs at risk: 16.93 % to the bladder, 50.81 % to the rectum, and 68.75 % to the femoral heads. These reductions highlight the dosimetric advantage of focused VHEE beams in sparing non-targeted tissues. While these results underscore the potential benefits of focused VHEE beams for deep-seated tumor treatment, additional research, including clinical validation and patient-specific modeling, is essential to fully evaluate their clinical utility. This study lays the groundwork for optimizing VHEE beam applications in cancer therapy by demonstrating improved dose delivery accuracy and reduced risk to adjacent organs.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 82 tautan kepenulisan bersama · 28 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université Ibn-Tofail
  • University of Hassan II Casablanca
  • Université Hassan 1er
  • Mohammed V University
  • National Centre for Nuclear Energy, Science and Technology
  • University of Lomé
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
El Mahjoub ChakirUniversité Ibn-Tofail3
Hassane El BekkouriUniversité Ibn-Tofail2
Elmehdi Al IbrahmiUniversité Ibn-Tofail2
Mohamed El-AseryUniversité Ibn-Tofail2
Adil BardaneUniversité Ibn-Tofail2
Zouhair SadouneUniversité Ibn-Tofail2
Otmane AllaouiUniversité Ibn-Tofail1
E. M. AlibrahmiUniversité Ibn-Tofail1
Zouhair SadouneUniversité Ibn-Tofail1
Khadija CharefUniversity of Hassan II Casablanca1
F. Z. AhlafUniversity of Hassan II Casablanca1
Youssef KhoulakiUniversity of Hassan II Casablanca1
Hicham HarrassUniversity of Hassan II Casablanca1
I. FathiUniversity of Hassan II Casablanca1
Youssef MakhkhasUniversity of Hassan II Casablanca1
K. AdambounouAfiliasi tidak diketahui1
Tomfey Essakpa BakoliaMohammed V University1
Rajaa SebihiMohammed V University1
Eyakifama HazouUniversity of Lomé1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Dosimetric Evaluation of Very High Energy Electron (VHEE) Beams in the Male Pelvic Region Using Geant4/TOPAS</dc:title>
	<dc:creator>Essaidi, E. M.</dc:creator>
	<dc:creator>Krim, M.</dc:creator>
	<dc:creator>Kaanouch, O.</dc:creator>
	<dc:creator>Tantaoui, M.</dc:creator>
	<dc:creator>Mesradi, M. R.</dc:creator>
	<dc:creator>Abdessamad, D.</dc:creator>
	<dc:creator>Benchekroun, D.</dc:creator>
	<dc:subject xml:lang="en-US">Very High Energy Electrons (VHEE)    Focused VHEE beams  Collimated VHEE beams  GEANT4/TOPAS Monte Carlo simulations  Quadrupole magnets Radiological Protection.</dc:subject>
	<dc:description xml:lang="en-US">The CLEAR (CERN Linear Electron Accelerator for Research) facility has significantly advanced high-energy electron radiotherapy, particularly for treating deep-seated tumors. However, achieving precise and accessible treatment delivery while minimizing damage to surrounding healthy tissues remains challenging. Very High Energy Electrons Beam (VHEE) offer notable potential due to their deep penetration capabilities. However, their nearly uniform dose distribution raises concerns about unintended exposure to healthy tissues. A key innovation in this field is the use of focused VHEE beams, which deliver a concentrated dose to a small defined area at a high dose rate, potentially enhancing treatment precision. This study evaluates the dosimetric characteristics of focused VHEE beams compared to collimated beams using GEANT4/TOPAS Monte Carlo simulations. A beamline with two quadrupole magnet triplets was designed to focus VHEE beams on a water phantom, simulating clinical conditions. The findings show that focused VHEE beams increased the dose to the prostate by 5.24 % while significantly reducing the dose to adjacent organs at risk: 16.93 % to the bladder, 50.81 % to the rectum, and 68.75 % to the femoral heads. These reductions highlight the dosimetric advantage of focused VHEE beams in sparing non-targeted tissues. While these results underscore the potential benefits of focused VHEE beams for deep-seated tumor treatment, additional research, including clinical validation and patient-specific modeling, is essential to fully evaluate their clinical utility. This study lays the groundwork for optimizing VHEE beam applications in cancer therapy by demonstrating improved dose delivery accuracy and reduced risk to adjacent organs.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-05-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1599</dc:identifier>
	<dc:identifier>10.55981/aij.2025.1599</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 51, No 2 (2025): AUGUST 2025; 109-117</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v51i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1599/1170</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1599/2611</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1599/2694</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1599/2691</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1599/2692</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1599/2693</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>