Construction and Evaluation of a Multipurpose Performance Check Phantom for Computed Tomography
Atom Indonesia · Vol. 46 No. 2 (2020) · hlm. 69–75
ISSN 2356-5322, 0126-1568
Terbit 2020-08-07
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
The use of computed tomography (CT) has become a common practice in medical diagnosis in Indonesia. Its number, however, is not matched by the availability of dedicated-performance-check phantoms. This paper aims to describe the design, construction, and evaluation of an in-house phantom for CT performance check that accommodates both radiation dose measurement and image quality performance checks. The phantom is designed as laser-cut polymethyl methacrylate (PMMA) slabs glued together to form a standard cylindrical shape, with spaces to place dose measurement and image quality modules. In this paper, measurement results on both aspects are discussed and compared with standard phantoms and other works. For dose measurement, the constructed phantom exhibited the greatest absolute discrepancy against the reference standard phantom of 8.89 %. Measurement of the CT number linearity and modulation transfer function (MTF) yielded, at most, 7.51 % and 5.07 % discrepancies against Catphan 604, respectively. Meanwhile, although found to be more linear in the phantom-based contrast linearity test, the use of the in-house phantom for clinical image contrast threshold determination requires further study. For noise power spectrum (NPS) measurement, accurate results were obtained within a limited range of spatial frequency.
Jaringan kolaborasi para penulis
26 penulis ·
80 tautan kepenulisan bersama
· 23 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Indonesia Kementerian Kesehatan Republik Indonesia Mulawarman University Dharmais Cancer Hospital Prudhoe Hospital Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo National Nuclear Energy Agency of Indonesia Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Construction and Evaluation of a Multipurpose Performance Check Phantom for Computed Tomography</dc:title>
<dc:creator>Lubis, L.E.</dc:creator>
<dc:creator>Hariyati, I.</dc:creator>
<dc:creator>Ryangga, D.</dc:creator>
<dc:creator>Mu'minah, I.A.S.</dc:creator>
<dc:creator>Mart, T.</dc:creator>
<dc:creator>Soejoko, D.S.</dc:creator>
<dc:subject xml:lang="en-US">Computed tomography; Dose; Image quality; Phantom</dc:subject>
<dc:description xml:lang="en-US">The use of computed tomography (CT) has become a common practice in medical diagnosis in Indonesia. Its number, however, is not matched by the availability of dedicated-performance-check phantoms. This paper aims to describe the design, construction, and evaluation of an in-house phantom for CT performance check that accommodates both radiation dose measurement and image quality performance checks. The phantom is designed as laser-cut polymethyl methacrylate (PMMA) slabs glued together to form a standard cylindrical shape, with spaces to place dose measurement and image quality modules. In this paper, measurement results on both aspects are discussed and compared with standard phantoms and other works. For dose measurement, the constructed phantom exhibited the greatest absolute discrepancy against the reference standard phantom of 8.89 %. Measurement of the CT number linearity and modulation transfer function (MTF) yielded, at most, 7.51 % and 5.07 % discrepancies against Catphan 604, respectively. Meanwhile, although found to be more linear in the phantom-based contrast linearity test, the use of the in-house phantom for clinical image contrast threshold determination requires further study. For noise power spectrum (NPS) measurement, accurate results were obtained within a limited range of spatial frequency.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US">Universitas Indonesia</dc:contributor>
<dc:date>2020-08-07</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1004</dc:identifier>
<dc:identifier>10.17146/aij.2020.1004</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; Vol 46, No 2 (2020): August 2020; 69-75</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v46i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1004/838</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1653</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1739</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1740</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1741</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1842</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1843</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1844</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1004/1845</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2019 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Lubis, L., Hariyati, I., Ryangga, D., Mu'minah, I., Mart, T., & Soejoko, D. (2020). Construction and Evaluation of a Multipurpose Performance Check Phantom for Computed Tomography. Atom Indonesia, 46(2), 69–75. https://doi.org/10.17146/aij.2020.1004
Salin
IEEE
L. Lubis, I. Hariyati, D. Ryangga, I. Mu'minah, T. Mart, and D. Soejoko, “Construction and Evaluation of a Multipurpose Performance Check Phantom for Computed Tomography,” Atom Indonesia, vol. 46, no. 2, pp. 69–75, 2020, doi: 10.17146/aij.2020.1004.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.