Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Reevaluation of MIBI as the Ligand of 99mTc-MIBI Radiopharmaceutical for Myocardial Imaging

Atom Indonesia · Vol. 34 No. 1 (2011) · hlm. 35–44

DOI
10.17146/aij.2008.88
ISSN
2356-5322, 0126-1568
Terbit
2011-12-27
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

Methoxy isobutyl isonitrile labelled with technetium-99m (99mTc) radionuclide can be used for the evaluation of acute myocardial infarction. The 99mTc-MIBI radiopharmaceutical is available in the lyophilized-kit, which is separately packed with its radionuclide. Recently, in CNTMR-BATAN Bandung, 99mTc-MIBI radiopharmaceutical was prepared using MIBI ligand synthesized in 1996 as lyophilized-kits having the radiochemical purity less than 90 % and not accumulated in the myocardium. It could be caused by several factors, among others were technical preparation of lyophilized dry-kit and the quality of MIBI; therefore the reevaluation of the ligand for the quality improvement was needed. Firstly, MIBI ligand was recristallized. It was found that MIBI as [Cu(MIBI)4]BF4 salt was a glassy solid with the melting point of 98 -99 oC. The infra red analysis showed the presence of spectra vibration at 1085, 1180 cm-1 and 2180, 2220 cm-1 for –OCH3 and N≡C groups, respectively. The preparation of 99mTc-MIBI was performed by adding 99mTc radionuclide into new MIBI liquid-kit, then boiled in water bath for minimum period of 10 minutes. The radiochemical purity of 99mTc-MIBI was analysed by thin layer chromatographic method using absolute ethanol as a mobile phase. The pre-clinical evaluation was observed in Wistar rat and clinical studies were performed in volunter using gamma camera. It is revealed that the radiochemical purity of more than 90 % i.e. 96.83 ± 1.43 % was still stable until 24 hours storage at room temperature. The stability studies of 99mTc-MIBI in human blood plasma showed that in 6 hours, the radiochemical purity was decreased to 90.89 ± 2.90 %. Clinical application of 99mTc-MIBI with tomography techniques using gamma camera showed the distinct accumulation of radioactivity in the heart.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 50 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Nuclear Energy Agency of Indonesia
  • Universitas Bakti Tunas Husada
  • Sekolah Tinggi Farmasi Indonesia
  • Bandung Institute of Technology
  • Nuclear Energy Agency
  • Padjadjaran University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I. MahendraAfiliasi tidak diketahui2
A. HanafiahSekolah Tinggi Farmasi Indonesia1
Maula Eka SriyaniNational Nuclear Energy Agency of Indonesia1
Nanny Kartini OekarNational Nuclear Energy Agency of Indonesia1
Nurlaila ZainuddinNational Nuclear Energy Agency of Indonesia1
Iim HalimahNational Nuclear Energy Agency of Indonesia1
S. R. PajrinSekolah Tinggi Farmasi Indonesia1
Witri NuraeniNational Nuclear Energy Agency of Indonesia1
T. H. AmbarwibawaNuclear Energy Agency1
Heni RachmawatiBandung Institute of Technology1
Aang Hanafiah WangsaatmadjaNational Nuclear Energy Agency of Indonesia1
DEBBIE SOEFIE RETNONINGRUMBandung Institute of Technology1
Veronika Yulianti SusiloNational Nuclear Energy Agency of Indonesia1
Ruswanto RuswantoUniversitas Bakti Tunas Husada1
Anindita Tri Kusuma PratitaUniversitas Bakti Tunas Husada1
Febby PratamaUniversitas Bakti Tunas Husada1
Tita NofiantiUniversitas Bakti Tunas Husada1
Holis Abdul HolikPadjadjaran University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Reevaluation of MIBI as the Ligand of 99mTc-MIBI Radiopharmaceutical for Myocardial Imaging</dc:title>
	<dc:creator>Nurlaila, Z.</dc:creator>
	<dc:creator>Daruwati, I.</dc:creator>
	<dc:subject xml:lang="en-US">Radiopharmaceutical; MIBI; 99mTc; Myocardial imaging.</dc:subject>
	<dc:description xml:lang="en-US">Methoxy isobutyl isonitrile labelled with technetium-99m (99mTc) radionuclide can be used for the evaluation of acute myocardial infarction. The 99mTc-MIBI radiopharmaceutical is available in the lyophilized-kit, which is separately packed with its radionuclide. Recently, in CNTMR-BATAN Bandung, 99mTc-MIBI radiopharmaceutical was prepared using MIBI ligand synthesized in 1996 as lyophilized-kits having the radiochemical purity less than 90 % and not accumulated in the myocardium. It could be caused by several factors, among others were technical preparation of lyophilized dry-kit and the quality of MIBI; therefore the reevaluation of the ligand for the quality improvement was needed. Firstly, MIBI ligand was recristallized. It was found that MIBI as [Cu(MIBI)4]BF4 salt was a glassy solid with the melting point of 98 -99 oC. The infra red analysis showed the presence of spectra vibration at 1085, 1180 cm-1 and 2180, 2220 cm-1 for –OCH3 and N≡C groups, respectively. The preparation of 99mTc-MIBI was performed by adding 99mTc radionuclide into new MIBI liquid-kit, then boiled in water bath for minimum period of 10 minutes. The radiochemical purity of 99mTc-MIBI was analysed by thin layer chromatographic method using absolute ethanol as a mobile phase. The pre-clinical evaluation was observed in Wistar rat and clinical studies were performed in volunter using gamma camera. It is revealed that the radiochemical purity of more than 90 % i.e. 96.83 ± 1.43 % was still stable until 24 hours storage at room temperature. The stability studies of 99mTc-MIBI in human blood plasma showed that in 6 hours, the radiochemical purity was decreased to 90.89 ± 2.90 %. Clinical application of 99mTc-MIBI with tomography techniques using gamma camera showed the distinct accumulation of radioactivity in the heart.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Nuclear Energy Agency of Indonesia</dc:contributor>
	<dc:date>2011-12-27</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/88</dc:identifier>
	<dc:identifier>10.17146/aij.2008.88</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 34, No 1 (2008): January 2008; 35-44</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.17146/aij.2008.%x</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/88/67</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>