Akses terbuka
Jurnal
SINTA 1
Comparison of Electron Density and Absorption Dose Values of Artificial Boluses as Tissue Substitutes
Atom Indonesia · Vol. 52 No. 2 (2026) · hlm. 105–112
ISSN 2356-5322, 0126-1568
Terbit 2026-06-05
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
According to the Skin Cancer Foundation (SCF), approximately 1.8 million new cases of Squamous Cell Carcinoma (SCC) were reported globally in 2023. Radiotherapy remains a common treatment modality for SCC. However, delivering the maximum dose directly to the skin surface is often impeded by the skin-sparing effect of high-energy photon and electron beams. To overcome this limitation, a bolus, a tissue-equivalent material, is applied to bring the dose closer to the surface. This study aims to evaluate the electron density values derived from CT images and the absorbed doses of boluses fabricated from three different materials: resin Lycal 1079 (a propylene glycol-based compound), silicone rubber (polydimethylsiloxane), and plasticine (a mixture of stearate salt and glycerin). Dosimetric measurements were conducted using 6 MV photon beams and 12 MeV electron beams. Image analysis was performed using ImageJ and Matlab softwares. The irradiation setup employed a Source-to-Surface Distance (SSD) of 100 cm and a 10 × 10 cm² field size. Relative Electron Density (RED) values obtained from ImageJ for the resin and silicone rubber boluses were 1.007 and 1.188, respectively, while Matlab yielded RED values of 1.094 for resin and 1.194 for silicone rubber. For the plasticine bolus, both software tools produced a consistent RED value of 1.101. The findings indicate that beam energy has a significant impact on the absorbed dose at various phantom depths. Furthermore, all bolus materials increased the absorbed dose compared to setups without a bolus. Among the three materials, the resin bolus exhibited the most favorable characteristics, with a RED value closely approximating that of breast and skin tissue, highlighting its potential as an effective and economical tissue-equivalent bolus for clinical radiotherapy applications.
Jaringan kolaborasi para penulis
34 penulis ·
79 tautan kepenulisan bersama
· 6 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Mulawarman University University of Brawijaya Lambung Mangkurat University University of Indonesia RSUD Prof. Dr. Saiful Anwar Malang Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Comparison of Electron Density and Absorption Dose Values of Artificial Boluses as Tissue Substitutes</dc:title>
<dc:creator>Putri, D. R.</dc:creator>
<dc:creator>Hentihu, F. K.</dc:creator>
<dc:creator>Stevenly, R. J.</dc:creator>
<dc:creator>Putri, E. R.</dc:creator>
<dc:subject xml:lang="en-US">Absorbed Dose; Bolus; Electrons; Photons; Relative Electron Density (RED)</dc:subject>
<dc:description xml:lang="en-US">According to the Skin Cancer Foundation (SCF), approximately 1.8 million new cases of Squamous Cell Carcinoma (SCC) were reported globally in 2023. Radiotherapy remains a common treatment modality for SCC. However, delivering the maximum dose directly to the skin surface is often impeded by the skin-sparing effect of high-energy photon and electron beams. To overcome this limitation, a bolus, a tissue-equivalent material, is applied to bring the dose closer to the surface. This study aims to evaluate the electron density values derived from CT images and the absorbed doses of boluses fabricated from three different materials: resin Lycal 1079 (a propylene glycol-based compound), silicone rubber (polydimethylsiloxane), and plasticine (a mixture of stearate salt and glycerin). Dosimetric measurements were conducted using 6 MV photon beams and 12 MeV electron beams. Image analysis was performed using ImageJ and Matlab softwares. The irradiation setup employed a Source-to-Surface Distance (SSD) of 100 cm and a 10 × 10 cm² field size. Relative Electron Density (RED) values obtained from ImageJ for the resin and silicone rubber boluses were 1.007 and 1.188, respectively, while Matlab yielded RED values of 1.094 for resin and 1.194 for silicone rubber. For the plasticine bolus, both software tools produced a consistent RED value of 1.101. The findings indicate that beam energy has a significant impact on the absorbed dose at various phantom depths. Furthermore, all bolus materials increased the absorbed dose compared to setups without a bolus. Among the three materials, the resin bolus exhibited the most favorable characteristics, with a RED value closely approximating that of breast and skin tissue, highlighting its potential as an effective and economical tissue-equivalent bolus for clinical radiotherapy applications.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-06-05</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1633</dc:identifier>
<dc:identifier>10.55981/aij.2026.1633</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; Vol 52, No 2 (2026): AUGUST 2026; 105-112</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v52i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1633/1218</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2736</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2737</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2946</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2969</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2970</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2971</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2972</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2973</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1633/2974</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Putri, D. R., Hentihu, F. K., Stevenly, R. J., & Putri, E. R. (2026). Comparison of Electron Density and Absorption Dose Values of Artificial Boluses as Tissue Substitutes. Atom Indonesia, 52(2), 105–112. https://doi.org/10.55981/aij.2026.1633
Salin
IEEE
D. R. Putri, F. K. Hentihu, R. J. Stevenly, and E. R. Putri, “Comparison of Electron Density and Absorption Dose Values of Artificial Boluses as Tissue Substitutes,” Atom Indonesia, vol. 52, no. 2, pp. 105–112, 2026, doi: 10.55981/aij.2026.1633.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.