Dose Response of Personnel OSL Dosimeter to the Cesium-137 and 80 kVp X-ray Exposure
Atom Indonesia · Vol. 49 No. 3 (2023) · hlm. 209–213
ISSN 2356-5322, 0126-1568
Terbit 2023-12-14
Penerbit National Research and Innovation Agency
Bahasa eng
Abstrak
Over the years, several types of dosimeters have been introduced for accurate dose assessment. The OSL dosimeter is one of them. It is used to monitor personnel dose from external exposure. In this paper, dose response of OSL dosimeters in terms of Hp(10) to Cs‑137 gamma and 80 kVp X‑ray radiation will be studied. The dosimeters were irradiated using Cs‑137 gamma and 80 kVp X‑ray to 0.5 mSv, 1 mSv, 3 mSv, 5 mSv, and 10 mSv at a distance of 200 cm, and all of them were subsequently read. Half of the dosimeters that were previously irradiated with a dose of 1 mSv and 5 mSv were read 30 times. The other half of the dosimeters were re-read on day 30 and day 60 from the initial reading. The study shows that relations between measured dose and exposure dose for Cs‑137 gamma and 80 kVp X‑ray irradiation are linear with correlation coefficients (R2) of 0.9997 and 0.9987, respectively. When the OSL dosimeters were read repeatedly, a dose reduction for each reading occured by 0.4 % and 0.5 % on Cs‑137 gamma and 80 kVp X‑ray, respectively. Dose reading on day 60 after Cs‑137 gamma irradiation showed fading of 3.6 % and 2.7 % on OSL dosimeter exposed to 1 mSv and 5 mSv, respectively, whereas fading effect on 80 kVp X‑ray irradiation showed values of 5.9 % and 8.8 % for the two doses.
Jaringan kolaborasi para penulis
6 penulis ·
13 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
National Research and Innovation Agency Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Dose Response of Personnel OSL Dosimeter to the Cesium-137 and 80 kVp X-ray Exposure</dc:title>
<dc:creator>Jumpeno, E. B.</dc:creator>
<dc:creator>Anggraeni, R.</dc:creator>
<dc:creator>Barokah, S. N.</dc:creator>
<dc:creator>Syaifudin, R.</dc:creator>
<dc:subject xml:lang="en-US">Personnel OSL dosimeter; Hp(10); Cs 137; X-ray</dc:subject>
<dc:description xml:lang="en-US">Over the years, several types of dosimeters have been introduced for accurate dose assessment. The OSL dosimeter is one of them. It is used to monitor personnel dose from external exposure. In this paper, dose response of OSL dosimeters in terms of Hp(10) to Cs‑137 gamma and 80 kVp X‑ray radiation will be studied. The dosimeters were irradiated using Cs‑137 gamma and 80 kVp X‑ray to 0.5 mSv, 1 mSv, 3 mSv, 5 mSv, and 10 mSv at a distance of 200 cm, and all of them were subsequently read. Half of the dosimeters that were previously irradiated with a dose of 1 mSv and 5 mSv were read 30 times. The other half of the dosimeters were re-read on day 30 and day 60 from the initial reading. The study shows that relations between measured dose and exposure dose for Cs‑137 gamma and 80 kVp X‑ray irradiation are linear with correlation coefficients (R2) of 0.9997 and 0.9987, respectively. When the OSL dosimeters were read repeatedly, a dose reduction for each reading occured by 0.4 % and 0.5 % on Cs‑137 gamma and 80 kVp X‑ray, respectively. Dose reading on day 60 after Cs‑137 gamma irradiation showed fading of 3.6 % and 2.7 % on OSL dosimeter exposed to 1 mSv and 5 mSv, respectively, whereas fading effect on 80 kVp X‑ray irradiation showed values of 5.9 % and 8.8 % for the two doses.</dc:description>
<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
<dc:contributor xml:lang="en-US">National Research and Inovation Agency</dc:contributor>
<dc:date>2023-12-14</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1313</dc:identifier>
<dc:identifier>10.55981/aij.2023.1313</dc:identifier>
<dc:source xml:lang="en-US">Atom Indonesia; VOL 49, NO 3 (2023): DECEMBER 2023; 209-213</dc:source>
<dc:source>2356-5322</dc:source>
<dc:source>0126-1568</dc:source>
<dc:source>10.55981/aij.v49i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1313/1099</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1313/2368</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1313/2369</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1313/2370</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1313/2371</dc:relation>
<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1313/2372</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Atom Indonesia</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Jumpeno, E. B., Anggraeni, R., Barokah, S. N., & Syaifudin, R. (2023). Dose Response of Personnel OSL Dosimeter to the Cesium-137 and 80 kVp X-ray Exposure. Atom Indonesia, 49(3), 209–213. https://doi.org/10.55981/aij.2023.1313
Salin
IEEE
E. B. Jumpeno, R. Anggraeni, S. N. Barokah, and R. Syaifudin, “Dose Response of Personnel OSL Dosimeter to the Cesium-137 and 80 kVp X-ray Exposure,” Atom Indonesia, vol. 49, no. 3, pp. 209–213, 2023, doi: 10.55981/aij.2023.1313.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.