Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Radiation Dose and Image Quality of Bladder Cancer Patients Analysis on Abdominal CT-Scan Examinations

Atom Indonesia · Vol. 51 No. 1 (2025) · hlm. 27–33

DOI
10.55981/aij.2025.1526
ISSN
2356-5322, 0126-1568
Terbit
2025-02-28
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

The bladder is a subperitoneal, hollow muscular organ that acts as areservoir for urine and located in the lower abdomen. Bladder cancer is one of health issues that can affect many people each year. Bladder cancer ranks as the 10th most common cancer worldwide. Early management includes cancer screening using abdominal CT-Scan. The objective of this study was to analyze the radiation dose received by patients and the image quality of patients underwent abdominal CT scans based on the Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values obtained. Data analysis management, specifically using quantitative analysis techniques, involved observing 20 bladder cancer patients with a total of 2,653 images. The IndoseCT software was used for analyzing the radiation dose to patients, while the IndoQCT software was used for analyzing image quality in CT-Abdomen examinations based on Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values. The results showed that the radiation dose received by patients during CT-Abdomen examinations was higher than the dose output by the device. The maximum dose output by the device (CTDIvol) was 50.10 mGy, and the minimum was 6.70 mGy, while the maximum dose received by patients (SSDE) was 53.34 mGy, and the minimum was 9.34 mGy. The image quality results for CT-Abdomen examinations based on SNR and CNR values indicated that the image quality obtained was adequate for diagnostic purposes.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 46 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mulawarman University
  • Lambung Mangkurat University
  • University of Indonesia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rahmawati MunirMulawarman University3
M. HamidMulawarman University2
A. Mu'tiAfiliasi tidak diketahui2
Sherly PutriMulawarman University2
Amar Vijai NasrullohLambung Mangkurat University1
Arfan Eko FahrudinLambung Mangkurat University1
R. JannahMulawarman University1
A. PutriAfiliasi tidak diketahui1
Retno ZurmaAfiliasi tidak diketahui1
A. NurMulawarman University1
Kholis NurhanafiMulawarman University1
Fatimah Kunti HentihuAfiliasi tidak diketahui1
D. R. (Dian) PutriMulawarman University1
Robert Janssen StevenlyAfiliasi tidak diketahui1
Prawito PrajitnoUniversity of Indonesia1
Djarwani Soeharso SoejokoUniversity of Indonesia1
Ahmad ZarkasiMulawarman University1
Dadan HamdaniMulawarman University1
Adrianus Inu NatalisantoMulawarman University1
Suhadi MuliyonoMulawarman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Radiation Dose and Image Quality of Bladder Cancer Patients Analysis on Abdominal  CT-Scan Examinations</dc:title>
	<dc:creator>Anthon, R.</dc:creator>
	<dc:creator>Intifadhah, S. H.</dc:creator>
	<dc:creator>Putri, E. R.</dc:creator>
	<dc:subject xml:lang="en-US">Abdomen; Contrast to Noise Ratio (CNR); Dose; Image; Signal to Noise Ratio (SNR)</dc:subject>
	<dc:description xml:lang="en-US">The bladder is a subperitoneal, hollow muscular organ that acts as areservoir for urine and located in the lower abdomen. Bladder cancer is one of health issues that can affect many people each year. Bladder cancer ranks as the 10th most common cancer worldwide. Early management includes cancer screening using abdominal CT-Scan. The objective of this study was to analyze the radiation dose received by patients and the image quality of patients underwent abdominal CT scans based on the Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values obtained. Data analysis management, specifically using quantitative analysis techniques, involved observing 20 bladder cancer patients with a total of 2,653 images. The IndoseCT software was used for analyzing the radiation dose   to patients, while the IndoQCT software was used for analyzing image quality in CT-Abdomen examinations based on Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values. The results showed that the radiation dose received by patients during CT-Abdomen examinations was higher than the dose output by the device. The maximum dose output by the device (CTDIvol) was 50.10 mGy, and the minimum was 6.70 mGy, while the maximum dose received by patients (SSDE) was 53.34 mGy, and the minimum was 9.34 mGy. The image quality results for CT-Abdomen examinations based on SNR and CNR values indicated that the image quality obtained was adequate for diagnostic purposes.</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-02-28</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/1526</dc:identifier>
	<dc:identifier>10.55981/aij.2025.1526</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 51, No 1 (2025): APRIL 2025; 27-33</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v51i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/1526/1153</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/1526/2634</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>