Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia

Atom Indonesia · Vol. 42 No. 3 (2016) · hlm. 99–104

DOI
10.17146/aij.2016.515
ISSN
2356-5322, 0126-1568
Terbit
2016-12-13
Penerbit
National Research and Innovation Agency
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0

Abstrak

The diagnostic reference levels form an efficient, concise, and powerful standard for optimizing the radiation protection of a patient. With an aim to contribute toward the establishment of the Indonesian National Diagnostic Reference Levels (NDRLs), a nationwide survey of the entrance surface doses received by adult patients during the most typical X-ray examinations has been performed. A number of 44 hospitals in 21 cities located in Java, Bali, Sumatera, Kalimantan, and Sulawesi islands were selected randomly to participate in this survey. Eight most common adult X-ray examinations in 13 projections, as well as four children X-ray examinations in six projections, were included in the list of procedures under consideration. Hospitals of different sizes and levels using different X-ray machines were represented in the survey. Standard thermoluminescence dosemeters were applied to measure entrance surface dose (ESD). A total of 1493 patients, consisting of 1208 adults and 285 children, were included in this study. The data were analyzed statistically and the minimum, median, mean, maximum, first quartile, and third quartile values of ESDs were reported. The ESDs calculated (third quartile) for adults varied from 0.18 mGy (for extremities AP) to 5.84 mGy (for lumbar spine LAT), and for children they varied from 0.16 mGy (for chest AP/PA) to 1.46 mGy (for skull AP/PA). Considering the geographic spread and size of Indonesia, those third quartile values calculated can only be regarded as preliminary DRL values for Indonesia. Compared with data from other countries, the calculated ESDs in this study are in general lower than the ESDs in those countries.Received: 16 November 2015; Revised: 27 April 2016; Accepted: 9 May 2016

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 47 tautan kepenulisan bersama · 27 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Nuclear Energy Agency of Indonesia
  • University of Indonesia
  • National Research and Innovation Agency
  • Kementerian Kesehatan Republik Indonesia
  • University of Malaya
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
H. SofyanNational Nuclear Energy Agency of Indonesia11
Kwan Hoong NgUniversity of Malaya3
Fendi nugrohoNational Research and Innovation Agency2
Okky Agassy FirmansyahNational Nuclear Energy Agency of Indonesia2
Bimo SaputroUniversity of Indonesia2
Adhi Harmoko SaputroUniversity of Indonesia2
Hasan MayditiaNational Research and Innovation Agency2
Djarwani Soeharso SoejokoUniversity of Indonesia1
Supriyanto Ardjo PawiroUniversity of Indonesia1
Nursama Heru ApriantoroKementerian Kesehatan Republik Indonesia1
Puji SupriyonoAfiliasi tidak diketahui1
Citra Elisabet SinagaKementerian Kesehatan Republik Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://atomindonesia.brin.go.id/index.php/aij/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia</dc:title>
	<dc:creator>Hiswara, E.</dc:creator>
	<dc:creator>Prasetio, H.</dc:creator>
	<dc:creator>Kartikasari, D.</dc:creator>
	<dc:creator>Nuraeni, N.</dc:creator>
	<dc:creator>Sandy, K.Y.P.</dc:creator>
	<dc:subject xml:lang="en-US">Diagnostic radiology;  Diagnostic reference levels; Adult patient doses; Entrance surface doses; Children patient doses</dc:subject>
	<dc:description xml:lang="en-US">The diagnostic reference levels form an efficient, concise, and powerful standard for optimizing the radiation protection of a patient. With an aim to contribute toward the establishment of the Indonesian National Diagnostic Reference Levels (NDRLs), a nationwide survey of the entrance surface doses received by adult patients during the most typical X-ray examinations has been performed. A number of 44 hospitals in 21 cities located in Java, Bali, Sumatera, Kalimantan, and Sulawesi islands were selected randomly to participate in this survey. Eight most common adult X-ray examinations in 13 projections, as well as four children X-ray examinations in six projections, were included in the list of procedures under consideration. Hospitals of different sizes and levels using different X-ray machines were represented in the survey. Standard thermoluminescence dosemeters were applied to measure entrance surface dose (ESD). A total of 1493 patients, consisting of 1208 adults and 285 children, were included in this study. The data were analyzed statistically and the minimum, median, mean, maximum, first quartile, and third quartile values of ESDs were reported. The ESDs calculated (third quartile) for adults varied from 0.18 mGy (for extremities AP) to 5.84 mGy (for lumbar spine LAT), and for children they varied from 0.16 mGy (for chest AP/PA) to 1.46 mGy (for skull AP/PA). Considering the geographic spread and size of Indonesia, those third quartile values calculated can only be regarded as preliminary DRL values for Indonesia. Compared with data from other countries, the calculated ESDs in this study are in general lower than the ESDs in those countries.Received: 16 November 2015; Revised: 27 April 2016; Accepted: 9 May 2016</dc:description>
	<dc:publisher xml:lang="en-US">National Research and Innovation Agency</dc:publisher>
	<dc:contributor xml:lang="en-US">National Nuclear Energy Agency of Indonesia</dc:contributor>
	<dc:date>2016-12-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://atomindonesia.brin.go.id/index.php/aij/article/view/515</dc:identifier>
	<dc:identifier>10.17146/aij.2016.515</dc:identifier>
	<dc:source xml:lang="en-US">Atom Indonesia; Vol 42, No 3 (2016): December 2016; 99-104</dc:source>
	<dc:source>2356-5322</dc:source>
	<dc:source>0126-1568</dc:source>
	<dc:source>10.55981/aij.v42i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/view/515/448</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/515/280</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/515/272</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/515/274</dc:relation>
	<dc:relation>https://atomindonesia.brin.go.id/index.php/aij/article/downloadSuppFile/515/276</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Atom Indonesia</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-nc-sa/4.0</dc:rights>
</oai_dc:dc>