Melola Discovery

← Melola Discovery

Jurnal SINTA 1

An Experimental Study of the TEG Performance using Cooling Systems of Waterblock and Heatsink-Fan

Automotive Experiences · Vol. 5 No. 3 (2022) · hlm. 261–267

DOI
10.31603/ae.6250
ISSN
2615-6636, 2615-6202
Terbit
2022-06-06
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

Two third of the total energy in the internal combustion engine (ICE) system is lost and turns as waste heat through the exhaust system and coolant circulations. Therefore, it is necessary to have a technology that is able to convert waste heat from ICE into electrical energy using thermal electric generator (TEG). To have the best thermoelectric generator (TEG) performance in terms of higher electricity generation, the temperature on the hot surface should be higher, and the temperature on the cold surface should be as low as feasible. The goal of the study was to study how differences in TEG cooling systems affected the overall performance. Water block and heatsink-fan are two different types of cooling systems that have been used in this experiment. The water flow rate in water block cooling systems varies between 200, 300, 400, 500, and 600 l/h. The TEG module was heated with gas-fired lighters. Arduino-based data loggers were used to record hot and cold temperatures on the TEG surface. A USB multimeter is used to measure TEG performance as electrical voltage. The results showed that 300 l/h was the best water flow rate for TEG cooling. When using a water block cooling system instead of a heat sink, the electrical voltage generated by the TEG module is 12 percent higher. This study found that a cooling system with water blocks is superior to heatsink-fan.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 72 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Muhammadiyah University of Surakarta
  • Sekolah Tinggi Teknologi Warga Surakarta
  • Universitas Muhammadiyah Surabaya
  • Bursa Uludağ Üni̇versi̇tesi̇
  • Kingston University London
  • Wuhan University of Technology
  • Sakarya Uygulamalı Bilimler Üniversitesi
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Fatimah Nur HidayahSekolah Tinggi Teknologi Warga Surakarta2
Haikal HaikalSekolah Tinggi Teknologi Warga Surakarta2
Amarulloh AmarullohSekolah Tinggi Teknologi Warga Surakarta2
Bagus Radiant UtomoUniversitas Muhammadiyah Surabaya2
David SetiadhiBursa Uludağ Üni̇versi̇tesi̇2
Denis R. MarchantKingston University London2
Xiaomeng ZhuWuhan University of Technology2
Samuel Ardhi KrisitiawanSekolah Tinggi Teknologi Warga Surakarta1
Aditya Praba WijayaMuhammadiyah University of Surakarta1
Agustinus Andrie PrasetyoMuhammadiyah University of Surakarta1
Desi GustianiSakarya Uygulamalı Bilimler Üniversitesi1
Akida MulyaningtyasMuhammadiyah University of Surakarta1
Muhammad Syafiq Al Fat’hanMuhammadiyah University of Surakarta1
Tri TjahjonoMuhammadiyah University of Surakarta1
NgafwanMuhammadiyah University of Surakarta1
Habibullah FathuroyanMuhammadiyah University of Surakarta1
Ilham DaroniMuhammadiyah University of Surakarta1
Rahmat Nur WijayaMuhammadiyah University of Surakarta1
Idang PratomoMuhammadiyah University of Surakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://journal.unimma.ac.id/index.php/AutomotiveExperiences/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">An Experimental Study of the TEG Performance using Cooling Systems of Waterblock and Heatsink-Fan</dc:title>
	<dc:creator xml:lang="en">Atmoko, Nugroho Tri</dc:creator>
	<dc:creator xml:lang="en">Jamaldi, Agus</dc:creator>
	<dc:creator xml:lang="en">Riyadi, Tri Widodo Besar</dc:creator>
	<dc:subject xml:lang="en">Thermoelectric generator</dc:subject>
	<dc:subject xml:lang="en">Water flow rate</dc:subject>
	<dc:subject xml:lang="en">Cooling system</dc:subject>
	<dc:subject xml:lang="en">Heatsink-fan</dc:subject>
	<dc:subject xml:lang="en">Water block</dc:subject>
	<dc:description xml:lang="en">Two third of the total energy in the internal combustion engine (ICE) system is lost and turns as waste heat through the exhaust system and coolant circulations. Therefore, it is necessary to have a technology that is able to convert waste heat from ICE into electrical energy using&amp;nbsp; thermal electric generator (TEG). To have the best thermoelectric generator (TEG) performance in terms of higher electricity generation, the temperature on the hot surface should be higher, and the temperature on the cold surface should be as low as feasible. The goal of the study was to study how differences in TEG cooling systems affected the overall performance. Water block and heatsink-fan are two different types of cooling systems that have been used in this experiment. The water flow rate in water block cooling systems varies between 200, 300, 400, 500, and 600 l/h. The TEG module was heated with gas-fired lighters. Arduino-based data loggers were used to record hot and cold temperatures on the TEG surface. A USB multimeter is used to measure TEG performance as electrical voltage. The results showed that 300 l/h was the best water flow rate for TEG cooling. When using a water block cooling system instead of a heat sink, the electrical voltage generated by the TEG module is 12 percent higher. This study found that a cooling system with water blocks is superior to heatsink-fan.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2022-06-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/AutomotiveExperiences/article/view/6250</dc:identifier>
	<dc:identifier>10.31603/ae.6250</dc:identifier>
	<dc:source xml:lang="en">Automotive Experiences; Vol. 5 No. 3 (2022); 261-267</dc:source>
	<dc:source>2615-6636</dc:source>
	<dc:source>2615-6202</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/AutomotiveExperiences/article/view/6250/3355</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 Nugroho Tri Atmoko, Agus Jamaldi, Tri Widodo Besar Riyadi</dc:rights>
</oai_dc:dc>