Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Experimental Stress Analysis on Frame Structure of A 70-Passengers Electric Bus

Automotive Experiences · Vol. 8 No. 2 (2025) · hlm. 401–414

DOI
10.31603/ae.13757
ISSN
2615-6636, 2615-6202
Terbit
2025-09-25
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

Structural strength testing of buses using static vertical load has not previously been explored to validate the structural integrity of bus frames. In this study, the static vertical load method was employed to validate the structural strength of the Universitas of Indonesia electric bus, which utilizes two different materials SS400 for the lower frame and Aluminum Alloy 6061 for the upper frame. Finite Element Analysis (FEA) was conducted to identify critical areas on both the lower and upper frames. The stress values in the simulation were also obtained at the same location as the strain gauge placements in the experiment. Experimental vertical load testing was carried out by incrementally applying a load of 1000 kg up to the equivalent of 70 passengers, with an additional dynamic coefficient of 30% resulting in a maximum load of 6850 kg. Strain measurements were taken using 20 strain gauges on the lower frame and 8 on the upper frame. The experimental result showed the highest stress occurred at strain gauge no. 9 on the lower frame, measuring 78.10 MPa, and 15.32 MPa on the upper frame under 6850 kg load. The comparison between the simulation and experimental results reveals an 18% deviation. Nevertheless, both methods indicate the same critical area of the structure. The stress distribution indicated that the central deck area of the lower frame, where passengers sit and stand, experienced the highest loads. On the upper frame, significant stress was observed in the area where the air conditioning system is mounted. These findings demonstrate that static vertical load testing can be effectively used to validate the structural strength and stress distribution of electric buses, particularly in areas subject to concentrated loading.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 103 tautan kepenulisan bersama · 35 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • University of Indonesia
  • Indonesian Institute of Sciences
  • Badan Pengkajian dan Penerapan Teknologi
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Djoko Wahyu KarmiadjiNational Research and Innovation Agency5
Mohammad AdhityaUniversity of Indonesia4
Sunarto KalegNational Research and Innovation Agency1
Yudan WhulanzaUniversity of Indonesia1
Alexander Christantho BudimanIndonesian Institute of Sciences1
Ogi IvanoBadan Pengkajian dan Penerapan Teknologi1
Mustasyar PerkasaNational Research and Innovation Agency1
Makmuri NuraminNational Research and Innovation Agency1
Yudi IrawadiNational Research and Innovation Agency1
Anwar AnwarNational Research and Innovation Agency1
Budi PrasetiyoNational Research and Innovation Agency1
Yana HeryanaNational Research and Innovation Agency1
Indra HardimanNational Research and Innovation Agency1
Saeful AndhiNational Research and Innovation Agency1
Wahyu PurnawirawanNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://journal.unimma.ac.id/index.php/AutomotiveExperiences/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Experimental Stress Analysis on Frame Structure of A 70-Passengers Electric Bus</dc:title>
	<dc:creator xml:lang="en">Kristianto, Stevanus Brian</dc:creator>
	<dc:creator xml:lang="en">Adhitya, Mohammad</dc:creator>
	<dc:creator xml:lang="en">Haryanto, Budi</dc:creator>
	<dc:creator xml:lang="en">Deprian, Lukyawan Pama</dc:creator>
	<dc:creator xml:lang="en">Aziz, Umar Abdul</dc:creator>
	<dc:creator xml:lang="en">Dwimansyah, Ridho</dc:creator>
	<dc:creator xml:lang="en">Sumarsono, Danardono Agus</dc:creator>
	<dc:subject xml:lang="en">Vertical load</dc:subject>
	<dc:subject xml:lang="en">Finite element analysis</dc:subject>
	<dc:subject xml:lang="en">Strain gauge</dc:subject>
	<dc:subject xml:lang="en">Bus frame</dc:subject>
	<dc:subject xml:lang="en">Electric bus</dc:subject>
	<dc:description xml:lang="en">Structural strength testing of buses using static vertical load has not previously been explored to validate the structural integrity of bus frames. In this study, the static vertical load method was employed to validate the structural strength of the Universitas of Indonesia electric bus, which utilizes two different materials SS400 for the lower frame and Aluminum Alloy 6061 for the upper frame. Finite Element Analysis (FEA) was conducted to identify critical areas on both the lower and upper frames. The stress values in the simulation were also obtained at the same location as the strain gauge placements in the experiment. Experimental vertical load testing was carried out by incrementally applying a load of 1000 kg up to the equivalent of 70 passengers, with an additional dynamic coefficient of 30% resulting in a maximum load of 6850 kg. Strain measurements were taken using 20 strain gauges on the lower frame and 8 on the upper frame. The experimental result showed the highest stress occurred at strain gauge no. 9 on the lower frame, measuring 78.10 MPa, and 15.32 MPa on the upper frame under 6850 kg load. The comparison between the simulation and experimental results reveals an 18% deviation.&amp;nbsp; Nevertheless, both methods indicate the same critical area of the structure. The stress distribution indicated that the central deck area of the lower frame, where passengers sit and stand, experienced the highest loads. On the upper frame, significant stress was observed in the area where the air conditioning system is mounted. These findings demonstrate that static vertical load testing can be effectively used to validate the structural strength and stress distribution of electric buses, particularly in areas subject to concentrated loading.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2025-09-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/AutomotiveExperiences/article/view/13757</dc:identifier>
	<dc:identifier>10.31603/ae.13757</dc:identifier>
	<dc:source xml:lang="en">Automotive Experiences; Vol. 8 No. 2 (2025); 401-414</dc:source>
	<dc:source>2615-6636</dc:source>
	<dc:source>2615-6202</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/AutomotiveExperiences/article/view/13757/6178</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Stevanus Brian Kristianto, Mohammad Adhitya, Budi Haryanto, Lukyawan Pama Deprian, Umar Abdul Aziz, Ridho Dwimansyah, Danardono Agus Sumarsono</dc:rights>
</oai_dc:dc>