Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Evaluation of Novel Integrated Dielectric Barrier Discharge Plasma as Ozone Generator

Bulletin of Chemical Reaction Engineering & Catalysis · Vol. ume (2017) · hlm. 24–31

DOI
10.9767/bcrec.12.1.605.24-31
ISSN
1978-2993
Terbit
2017-04-30
Penerbit
Masyarakat Katalis Indonesia - Indonesian Catalyst Society (MKICS)
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents a characterization of an integrated ozone generator constructed by seven of reactors of Dielectric Barrier Discharge Plasma (DBDP). DBDP a has spiral-cylindrical configuration. Silence plasma produced ozone inside the DBDP reactor was generated by AC-HV with voltage up to 25 kV and maximum frequency of 23 kHz. As a source of ozone, dry air was pumped into the generator and controlled by valves system and a flowmeter. We found ozone concentration increased with the applied voltage, but in contrary, the concentration decreased with the flow rate of dry air. It was also found that a maximum concentration was 20 mg/L and ozone capacity of 48 g/h with an input power of 1.4 kW. Moreover, in this generator, IP efficiency of 8.13 g/kWh was obtained at input power 0.45 kW and air flow rate of 9 L/min. Therefore, be the higher ozone capacity can be produced with higher input power; however, it provided lower IP efficiency. The effect of dry air flow rate and applied voltage on ozone concentrations have been studied. At last, spiral wire copper was very corrosive done to the interaction with ozone, and it is necessary to do a research for finding the best metals as an active electrode inside of the quartz dielectric.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 99 tautan kepenulisan bersama · 28 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Diponegoro University
  • Universitas Jember
  • Universitas PGRI Semarang
  • Tun Hussein Onn University of Malaysia
  • Sunan Kalijaga State Islamic University Yogyakarta
  • Universiti Brunei Darussalam
  • National Nuclear Energy Agency of Indonesia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Eko HidayantoDiponegoro University2
Affandi Faisal KurniawanUniversitas PGRI Semarang2
Ummi KaltsumUniversitas PGRI Semarang2
Priyono PriyonoDiponegoro University2
Ulfi NadzifahDiponegoro University1
Erma PrihasantiDiponegoro University1
F. M. SalimDiponegoro University1
Wahyu SetiabudiDiponegoro University1
Imam KambaliNational Nuclear Energy Agency of Indonesia1
Muhammad RezkiDiponegoro University1
Hadi NurUniversity of Technology Malaysia1
Hashim SaimTun Hussein Onn University of Malaysia1
Mohd Arif AgamTun Hussein Onn University of Malaysia1
Eko Sulkhani YuliantoDiponegoro University1
Agus SudarmantoWalisongo State Islamic University1
Arvia ArviaDiponegoro University1
Nor Basid Adiwibawa PrasetyaDiponegoro University1
Ahmad JauhariDiponegoro University1
Nita HandayaniSunan Kalijaga State Islamic University Yogyakarta1
Kevin Kautsar SoelistiyonoSunan Kalijaga State Islamic University Yogyakarta1
Nurul Wahyu PuspaningrumAfiliasi tidak diketahui1
Ida NursatiAfiliasi tidak diketahui1
Muhammad Danu RizkiaDiponegoro University1
Moh Arif RaziqyAfiliasi tidak diketahui1
Suryani AlifahAfiliasi tidak diketahui1
Bambang SupenoUniversitas Jember1
Triwahju HardiantoUniversitas Jember1
Dedy Kurnia SetiawanUniversitas Jember1
Yayuk AstutiDiponegoro University1
Fauzan MusthafaDiponegoro University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.bcrec.id/index.php/bcrec/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Evaluation of Novel Integrated Dielectric Barrier Discharge Plasma as Ozone Generator</dc:title>
	<dc:creator>Nur, Muhammad</dc:creator>
	<dc:creator>Susan, Ade Ika</dc:creator>
	<dc:creator>Muhlisin, Zaenul</dc:creator>
	<dc:creator>Arianto, Fajar</dc:creator>
	<dc:creator>Kinandana, Andi Wibowo</dc:creator>
	<dc:creator>Nurhasanah, Iis</dc:creator>
	<dc:creator>Sumariyah, Sumariyah</dc:creator>
	<dc:creator>Wibawa, Pratama Jujur</dc:creator>
	<dc:creator>Gunawan, Gunawan</dc:creator>
	<dc:creator>Usman, Anwar</dc:creator>
	<dc:subject xml:lang="en-US">ozone generator; dielectric barrier discharge; ozone; corrosion; electrode</dc:subject>
	<dc:description xml:lang="en-US">This paper presents a characterization of an integrated ozone generator constructed by seven of reactors of Dielectric Barrier Discharge Plasma (DBDP). DBDP a has spiral-cylindrical configuration. Silence plasma produced ozone inside the DBDP reactor was generated by AC-HV with voltage up to 25 kV and maximum frequency of 23 kHz. As a source of ozone, dry air was pumped into the generator and controlled by valves system and a flowmeter. We found ozone concentration increased with the applied voltage, but in contrary, the concentration decreased with the flow rate of dry air. It was also found that a maximum concentration was 20 mg/L and ozone capacity of 48 g/h with an input power of 1.4 kW. Moreover, in this generator, IP efficiency of 8.13 g/kWh was obtained at input power 0.45 kW and air flow rate of 9 L/min. Therefore, be the higher ozone capacity can be produced with higher input power; however, it provided lower IP efficiency. The effect of dry air flow rate and applied voltage on ozone concentrations have been studied. At last, spiral wire copper was very corrosive done to the interaction with ozone, and it is necessary to do a research for finding the best metals as an active electrode inside of the quartz dielectric. </dc:description>
	<dc:publisher xml:lang="en-US">Masyarakat Katalis Indonesia - Indonesian Catalyst Society (MKICS)</dc:publisher>
	<dc:contributor xml:lang="en-US">Ministry of  Research, Technology and High Education of Indonesia</dc:contributor>
	<dc:date>2017-04-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.bcrec.id/index.php/bcrec/article/view/605</dc:identifier>
	<dc:identifier>10.9767/bcrec.12.1.605.24-31</dc:identifier>
	<dc:source xml:lang="en-US">Bulletin of Chemical Reaction Engineering &amp; Catalysis; 2017: BCREC Volume 12 Issue 1 Year 2017 (April 2017); 24-31</dc:source>
	<dc:source>1978-2993</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.bcrec.id/index.php/bcrec/article/view/605/612</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 by Authors, Published by BCREC Group</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>