Akses terbuka
Jurnal
SINTA 1
Vision Transformer for Cataract Detection in Anterior Eye Images: Achieving Optimal Performance with Limited Data
CommIT (Communication and Information Technology) Journal · Vol. 20 No. 2 (2026) · hlm. 297–311
ISSN 2460-7010, 1979-2484
Terbit 2026-08-13
Penerbit Bina Nusantara University
Bahasa eng
Abstrak
Convolutional Neural Networks (CNNs) continue to face several challenges in cataract classification using image data, particularly due to limitations in dataset size and variability in color, shape, and position. These constraints arise because CNNs primarily process local features within each layer. The research uses Vision Transformer (ViT) to capture global spatial relationships in front-eye images. ViT can detect cataracts more accurately than CNN-based owing to its capability of modeling long-range dependencies. The research aims to evaluate ViT’s performance on four publicly available cataract datasets using training time, accuracy, precision, recall, and F1-score. To assess the model’s reliability when working with a small number of training datasets, ViT’s performance is also compared with ResNet-50 and EfficientNet-B7. The results indicate that ViT outperforms ResNet-50 in accuracy by 10%–31% and exceeds EfficientNet-B7 by 30%–41%. However, ViT requires approximately 16 seconds longer to train than ResNet-50 and EfficientNet-B7 due to its deeper architecture. Although ViT’s accuracy is 2.47% lower than previous studies using hybrid deep learning approaches, its parameter structure is simpler. Overall, the findings indicate that, compared with CNN-based models, ViT performs more effectively when trained on smaller datasets. Future research may incorporate segmentation techniques to further validate cataract detection in anterior eye images.
Jaringan kolaborasi para penulis
6 penulis ·
7 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Krida Wacana Christian University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.binus.ac.id/index.php/commit/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Vision Transformer for Cataract Detection in Anterior Eye Images: Achieving Optimal Performance with Limited Data</dc:title>
<dc:creator>Sevani, Nina</dc:creator>
<dc:creator>Agustinus, Westlee Matthew</dc:creator>
<dc:creator>Kristianto, Edy</dc:creator>
<dc:subject xml:lang="en-US">Cataract Detection</dc:subject>
<dc:subject xml:lang="en-US">Vision Transformer (ViT)</dc:subject>
<dc:subject xml:lang="en-US">Anterior Eye Images</dc:subject>
<dc:description xml:lang="en-US">Convolutional Neural Networks (CNNs) continue to face several challenges in cataract classification using image data, particularly due to limitations in dataset size and variability in color, shape, and position. These constraints arise because CNNs primarily process local features within each layer. The research uses Vision Transformer (ViT) to capture global spatial relationships in front-eye images. ViT can detect cataracts more accurately than CNN-based owing to its capability of modeling long-range dependencies. The research aims to evaluate ViT’s performance on four publicly available cataract datasets using training time, accuracy, precision, recall, and F1-score. To assess the model’s reliability when working with a small number of training datasets, ViT’s performance is also compared with ResNet-50 and EfficientNet-B7. The results indicate that ViT outperforms ResNet-50 in accuracy by 10%–31% and exceeds EfficientNet-B7 by 30%–41%. However, ViT requires approximately 16 seconds longer to train than ResNet-50 and EfficientNet-B7 due to its deeper architecture. Although ViT’s accuracy is 2.47% lower than previous studies using hybrid deep learning approaches, its parameter structure is simpler. Overall, the findings indicate that, compared with CNN-based models, ViT performs more effectively when trained on smaller datasets. Future research may incorporate segmentation techniques to further validate cataract detection in anterior eye images.
</dc:description>
<dc:publisher xml:lang="en-US">Bina Nusantara University</dc:publisher>
<dc:date>2026-08-13</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.binus.ac.id/index.php/commit/article/view/13529</dc:identifier>
<dc:identifier>10.21512/commit.v20i2.13529</dc:identifier>
<dc:source xml:lang="en-US">CommIT (Communication and Information Technology) Journal; Vol. 20 No. 2 (2026): CommIT Journal ; 297-311</dc:source>
<dc:source>2460-7010</dc:source>
<dc:source>1979-2484</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.binus.ac.id/index.php/commit/article/view/13529/5815</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Nina Sevani, Westlee Matthew Agustinus, Edy Kristianto</dc:rights>
<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Sevani, N., Agustinus, W. M., & Kristianto, E. (2026). Vision Transformer for Cataract Detection in Anterior Eye Images: Achieving Optimal Performance with Limited Data. CommIT (Communication and Information Technology) Journal, 20(2), 297–311. https://doi.org/10.21512/commit.v20i2.13529
Salin
IEEE
N. Sevani, W. M. Agustinus, and E. Kristianto, “Vision Transformer for Cataract Detection in Anterior Eye Images: Achieving Optimal Performance with Limited Data,” CommIT (Communication and Information Technology) Journal, vol. 20, no. 2, pp. 297–311, 2026, doi: 10.21512/commit.v20i2.13529.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.