Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design and Performance Analysis of a Point-to-Point LoRa-Based Wearable Health Monitoring System in Line-of-Sight (LOS) and Indoor Environments

CommIT (Communication and Information Technology) Journal · Vol. 20 No. 2 (2026) · hlm. 329–346

DOI
10.21512/commit.v20i2.14927
ISSN
2460-7010, 1979-2484
Terbit
2026-08-20
Penerbit
Bina Nusantara University
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This research presents the design and performance evaluation of a Long Range (LoRa)-based wearable health monitoring system for real-time transmission of physiological data, namely heart rate, blood oxygen saturation (SpO2), and body temperature. The system integrates a MAX30105 sensor with an ESP32-C3 microcontroller and an SX1276 LoRa module to enable lowpower, long-range communication for Internet of Medical Things (IoMT) applications. Testing is conducted under Line of Sight (LOS) and indoor conditions to examine the effect of distance and propagation characteristics on Received Signal Strength Indicator (RSSI), transmission delay, and data transfer speed (bps). Pearson correlation, linear regression, and one-way Analysis of Variance (ANOVA) are applied to quantify distance-performance relationships and compare both environments. Results show that increasing distance degrades performance in a near-linear pattern, with decreasing RSSI and transfer speed and increasing delay. Stable communication is maintained up to 500 m under LOS, whereas indoor performance deteriorates earlier due to attenuation and multipath propagation. Although ANOVA indicates no statistically significant difference in the average performance of successfully received packets (p > 0.05), practical evaluation reveals that indoor environments impose a shorter effective range with higher packet loss. The novelty lies in implementing a compact point-to-point LoRa wearable platform based on ESP32-C3 and SX1276 for real physiological payload transmission, combined with statistical performance evaluation under practical LOS and indoor scenarios without relying on Long Range Wide Area Network (LoRaWAN) infrastructure. These findings demonstrate that LoRa is a viable and energyefficient communication solution for wearable health monitoring, particularly in remote and infrastructurelimited IoMT applications.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 7 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Nahdlatul Ulama Yogyakarta
  • Telkom University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aswindha NasrullahAfiliasi tidak diketahui1
Muhammad IkhsanudinUniversitas Nahdlatul Ulama Yogyakarta1
Bledug Kusuma PrasajaUniversitas Nahdlatul Ulama Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.binus.ac.id/index.php/commit/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and Performance Analysis of a Point-to-Point LoRa-Based Wearable Health Monitoring System in Line-of-Sight (LOS) and Indoor Environments</dc:title>
	<dc:creator>Ardiansyah, Rio</dc:creator>
	<dc:creator>Novianto, Irwan</dc:creator>
	<dc:creator>Satrya, Gandeva Bayu</dc:creator>
	<dc:subject xml:lang="en-US">Long Range (LoRa)</dc:subject>
	<dc:subject xml:lang="en-US">Wearable Health Monitoring</dc:subject>
	<dc:subject xml:lang="en-US">Line-of-Sight (LOS) Environments</dc:subject>
	<dc:subject xml:lang="en-US">Indoor Environment</dc:subject>
	<dc:description xml:lang="en-US">This research presents the design and performance evaluation of a Long Range (LoRa)-based wearable health monitoring system for real-time transmission of physiological data, namely heart rate, blood oxygen saturation (SpO2), and body temperature. The system integrates a MAX30105 sensor with an ESP32-C3 microcontroller and an SX1276 LoRa module to enable lowpower, long-range communication for Internet of Medical Things (IoMT) applications. Testing is conducted under Line of Sight (LOS) and indoor conditions to examine the effect of distance and propagation characteristics on Received Signal Strength Indicator (RSSI), transmission delay, and data transfer speed (bps). Pearson correlation, linear regression, and one-way Analysis of Variance (ANOVA) are applied to quantify distance-performance relationships and compare both environments. Results show that increasing distance degrades performance in a near-linear pattern, with decreasing RSSI and transfer speed and increasing delay. Stable communication is maintained up to 500 m under LOS, whereas indoor performance deteriorates earlier due to attenuation and multipath propagation. Although ANOVA indicates no statistically significant difference in the average performance of successfully received packets (p &amp;gt; 0.05), practical evaluation reveals that indoor environments impose a shorter effective range with higher packet loss. The novelty lies in implementing a compact point-to-point LoRa wearable platform based on ESP32-C3 and SX1276 for real physiological payload transmission, combined with statistical performance evaluation under practical LOS and indoor scenarios without relying on Long Range Wide Area Network (LoRaWAN) infrastructure. These findings demonstrate that LoRa is a viable and energyefficient communication solution for wearable health monitoring, particularly in remote and infrastructurelimited IoMT applications.
 
</dc:description>
	<dc:publisher xml:lang="en-US">Bina Nusantara University</dc:publisher>
	<dc:date>2026-08-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.binus.ac.id/index.php/commit/article/view/14927</dc:identifier>
	<dc:identifier>10.21512/commit.v20i2.14927</dc:identifier>
	<dc:source xml:lang="en-US">CommIT (Communication and Information Technology) Journal; Vol. 20 No. 2 (2026): CommIT Journal ; 329-346</dc:source>
	<dc:source>2460-7010</dc:source>
	<dc:source>1979-2484</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.binus.ac.id/index.php/commit/article/view/14927/5821</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Rio Ardiansyah, Irwan Novianto, Gandeva Bayu Satrya</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>