Optic disc (OD), especially its diameter together with optic cup diameter can be used as a feature to diagnose glaucoma. This study contains two main steps for optic disc localisation, i.e. OD centre point detection and OD diameter determination. Centre point of OD is obtained by finding brightness pixel value based on average filtering.  After that, OD diameter is measured from the detected optic disc boundary. The proposed scheme is validated on 30 healthy and glaucoma retinal fundus images from HRF database.  The results are compared to the ground truth images. The proposed scheme obtains evaluation result (E) for healthy and glaucoma images is 0.23 and 0.21, respectively. These results indicate successful implementation of automated OD localisation by detecting OD centre point and determining OD diameter.

Kata kunci

Jaringan kolaborasi para penulis

34 penulis · 80 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Telkom University
  • Universitas Islam Negeri Imam Bonjol Padang
  • Sunan Gunung Djati State Islamic University Bandung
  • State University of Semarang
  • Institut Teknologi Telkom Purwokerto
  • Islamic University of Indonesia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Igi ArdiyantoUniversitas Gadjah Mada4
Noor Akhmad SetiawanUniversitas Gadjah Mada4
Lina ChoridahUniversitas Gadjah Mada3
Indah SoesantiUniversitas Gadjah Mada3
Achmad RizalTelkom University2
Risanuri HidayatUniversitas Gadjah Mada2
Aulia ArhamUniversitas Islam Negeri Imam Bonjol Padang2
Hasnely HasnelyAfiliasi tidak diketahui2
Budi WindartaUniversitas Gadjah Mada2
Christianus Frederick HotamaUniversitas Gadjah Mada2
Faza Maula AzifUniversitas Gadjah Mada2
Willy Anugrah CahyadiTelkom University1
Tri Putri LestariSunan Gunung Djati State Islamic University Bandung1
Rezty Amalia ArasUniversitas Gadjah Mada1
Anan NugrohoState University of Semarang1
Oyas WahyunggoroUniversitas Gadjah Mada1
Herryawan PujiharsonoInstitut Teknologi Telkom Purwokerto1
Febry Putra RochimUniversitas Gadjah Mada1
M. Azka PutraUniversitas Gadjah Mada1
Hanung Adi NugrohoUniversitas Gadjah Mada1
Vesi YulyantiUniversitas Gadjah Mada1
Chandra Ramadhan Atmaja PerdanaUniversitas Gadjah Mada1
Suatmi MurnaniIslamic University of Indonesia1
Dian Nova Kusuma HardaniMuhammadiyah University Purwokerto1
Aqil AqthobirrobbanyUniversitas Gadjah Mada1
Syukron Abu Ishaq AlfaroziUniversitas Gadjah Mada1
Etik IrijantiMuhammadiyah University of Yogyakarta1
Teguh Bharata AdjiUniversitas Gadjah Mada1
Fauziazzuhry RahadianUniversitas Gadjah Mada1
Ratna Lestari Budiani BuanaUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://cst.kipmi.or.id/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Automated localisation of optic disc in retinal colour fundus image for assisting in the diagnosis of glaucoma</dc:title>
	<dc:creator>Listyalina, Latifah</dc:creator>
	<dc:creator>Nugroho, Hanung Adi</dc:creator>
	<dc:creator>Wibirama, Sunu</dc:creator>
	<dc:creator>Oktoeberza, Widhia KZ</dc:creator>
	<dc:subject xml:lang="en-US">Optic disc centre point</dc:subject>
	<dc:subject xml:lang="en-US">optic disc diameter</dc:subject>
	<dc:subject xml:lang="en-US">retinal image</dc:subject>
	<dc:subject xml:lang="en-US">glaucoma</dc:subject>
	<dc:description xml:lang="en-US">Optic disc (OD), especially its diameter together with optic cup diameter can be used as a feature to diagnose glaucoma. This study contains two main steps for optic disc localisation, i.e. OD centre point detection and OD diameter determination.  Centre point of OD is obtained by finding brightness pixel value based on average filtering.  After that, OD diameter is measured from the detected optic disc boundary.  The proposed scheme is validated on 30 healthy and glaucoma retinal fundus images from HRF database.  The results are compared to the ground truth images.  The proposed scheme obtains evaluation result (E) for healthy and glaucoma images is 0.23 and 0.21, respectively.  These results indicate successful implementation of automated OD localisation by detecting OD centre point and determining OD diameter.</dc:description>
	<dc:publisher xml:lang="en-US">Komunitas Ilmuwan dan Profesional Muslim Indonesia</dc:publisher>
	<dc:date>2017-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://cst.kipmi.or.id/journal/article/view/43</dc:identifier>
	<dc:identifier>10.21924/cst.2.1.2017.43</dc:identifier>
	<dc:source xml:lang="en-US">Communications in Science and Technology; Vol. 2 No. 1 (2017)</dc:source>
	<dc:source xml:lang="id-ID">Communications in Science and Technology; Vol 2 No 1 (2017)</dc:source>
	<dc:source>2502-9266</dc:source>
	<dc:source>2502-9258</dc:source>
	<dc:source>10.21924/cst.2.1.2017</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://cst.kipmi.or.id/journal/article/view/43/17</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Communications in Science and Technology</dc:rights>
</oai_dc:dc>