Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Leak detection optimisation on retina fluorescein angiography images using phase stretch transform for malaria retinopathy

Optimasi Deteksi Kebocoran dengan Menggunakan Phase Stretch Transform pada Retina Fluorescein Angiography Images untuk Penyakit Malaria

Communications in Science and Technology · Vol. 3 No. 2 (2018) · hlm. 44–47

DOI
10.21924/cst.3.2.2018.82
ISSN
2502-9266, 2502-9258
Terbit
2018-12-25
Penerbit
Komunitas Ilmuwan dan Profesional Muslim Indonesia
Bahasa
eng

Abstrak

Malarial Retinopathy (MR) is indicated by retina alteration such as white dots occurrence which is caused by malaria. Leak detection is a key factor of MR’s early diagnosis. Inconsistent size and shape of the leakages with the colour contrast that relatively similar with the background. Leak detection’s algorithm is one of the most complex algorithms on the fundus image analysis field. Therefore, improving performance in the leakage detection is essential. This study focuses on automated leakage detection on fluorescein angiography (FA) images. The methods used in this study are vessel segmentation, saliency detection, phase stretch transform (PST), optic disk removal and leak detection to extract some features which then classified to correctly validate the leak. From 20 patient data large focal leak images with 31 leak points, 28 of them have been correctly detected. So, the experiment produced the accuracy and specificity of 0.98 and 0.9, respectively. With the proposed method of this study, there is a potential to enhance the knowledge on MR field in the future.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 86 tautan kepenulisan bersama · 22 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Telkom University
  • Universitas Islam Negeri Imam Bonjol Padang
  • Sunan Gunung Djati State Islamic University Bandung
  • State University of Semarang
  • Universitas Halu Oleo
  • Institut Teknologi Telkom Purwokerto
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sunu WibiramaUniversitas Gadjah Mada5
Igi ArdiyantoUniversitas Gadjah Mada3
Lina ChoridahUniversitas Gadjah Mada3
Indah SoesantiUniversitas Gadjah Mada3
Teguh Bharata AdjiUniversitas Gadjah Mada3
Achmad RizalTelkom University2
Risanuri HidayatUniversitas Gadjah Mada2
Widhia K.Z. OktoeberzaUniversitas Gadjah Mada2
Aulia ArhamUniversitas Islam Negeri Imam Bonjol Padang2
Anan NugrohoState University of Semarang2
Oyas WahyunggoroUniversitas Gadjah Mada2
Willy Anugrah CahyadiTelkom University1
Sri KusrohmaniahUniversitas Gadjah Mada1
Supra WimbartiUniversitas Gadjah Mada1
Ajeng Rintan SeptianiUniversitas Gadjah Mada1
Tri Putri LestariSunan Gunung Djati State Islamic University Bandung1
Rezty Amalia ArasUniversitas Gadjah Mada1
Hasnely HasnelyAfiliasi tidak diketahui1
Budi WindartaUniversitas Gadjah Mada1
Adha Mashur SajiahUniversitas Halu Oleo1
Latifah ListyalinaUniversitas Gadjah Mada1
Christianus Frederick HotamaUniversitas Gadjah Mada1
Herryawan PujiharsonoInstitut Teknologi Telkom Purwokerto1
Faza Maula AzifUniversitas Gadjah Mada1
M. Azka PutraUniversitas Gadjah Mada1
Rudy HartantoUniversitas Gadjah Mada1
Taftazani Ghazi PratamaUniversitas Gadjah Mada1
Chandra Ramadhan Atmaja PerdanaUniversitas Gadjah Mada1
Adi WijayaUniversitas Gadjah Mada1
Lukito Edi NugrohoUniversitas Gadjah Mada1
Syafira Fitri AuliyaUniversitas Gadjah Mada1
Suatmi MurnaniIslamic University of Indonesia1
Dian Nova Kusuma HardaniMuhammadiyah University Purwokerto1
Aqil AqthobirrobbanyUniversitas Gadjah Mada1
Rifkie PrimarthaSriwijaya University1
Farhatul FityahUniversitas Gadjah Mada1
Dyah Wulan AnggrahiniUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://cst.kipmi.or.id/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Leak detection optimisation on retina fluorescein angiography images using phase stretch transform for malaria retinopathy</dc:title>
	<dc:title xml:lang="id-ID">Optimasi Deteksi Kebocoran dengan Menggunakan Phase Stretch Transform pada Retina Fluorescein Angiography Images untuk Penyakit Malaria</dc:title>
	<dc:creator>Rochim, Febry Putra</dc:creator>
	<dc:creator>Nugroho, Hanung Adi</dc:creator>
	<dc:creator>Setiawan, Noor Akhmad</dc:creator>
	<dc:subject xml:lang="en-US">malaria disease; retina haemorrhage; phase stretch transform; fluorescein angiography</dc:subject>
	<dc:description xml:lang="en-US">Malarial Retinopathy (MR) is indicated by retina alteration such as white dots occurrence which is caused by malaria. Leak detection is a key factor of MR’s early diagnosis.&amp;nbsp; Inconsistent size and shape of the leakages with the colour contrast that relatively similar with the background. Leak detection’s algorithm is one of the most complex algorithms on the fundus image analysis field. Therefore, improving performance in the leakage detection is essential. This study focuses on automated leakage detection on fluorescein angiography (FA) images. The methods used in this study are vessel segmentation, saliency detection, phase stretch transform (PST), optic disk removal and leak detection to extract some features which then classified to correctly validate the leak. From 20 patient data large focal leak images with 31 leak points, 28 of them have been correctly detected. So, the experiment produced the accuracy and specificity of 0.98 and 0.9, respectively. With the proposed method of this study, there is a potential to enhance the knowledge on MR field in the future.</dc:description>
	<dc:publisher xml:lang="en-US">Komunitas Ilmuwan dan Profesional Muslim Indonesia</dc:publisher>
	<dc:date>2018-12-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://cst.kipmi.or.id/journal/article/view/82</dc:identifier>
	<dc:identifier>10.21924/cst.3.2.2018.82</dc:identifier>
	<dc:source xml:lang="en-US">Communications in Science and Technology; Vol. 3 No. 2 (2018); 44-47</dc:source>
	<dc:source xml:lang="id-ID">Communications in Science and Technology; Vol 3 No 2 (2018); 44-47</dc:source>
	<dc:source>2502-9266</dc:source>
	<dc:source>2502-9258</dc:source>
	<dc:source>10.21924/cst.3.2.2018</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://cst.kipmi.or.id/journal/article/view/82/46</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Communications in Science and Technology</dc:rights>
</oai_dc:dc>