Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Pelepasan ion nikel dan kromium kawat Australia dan stainless steel dalam saliva buatan (The release of nickel and chromium ions from Australian wire and stainless steel in artificial saliva)

Dental Journal (Majalah Kedokteran Gigi) · Vol. 47 No. 3 (2014) · hlm. 168–172

DOI
10.20473/j.djmkg.v47.i3.p168-172
ISSN
2442-9740, 1978-3728
Terbit
2014-09-01
Penerbit
Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa
eng

Abstrak

Background: Fixed orthodontic treatment needs several types of wire to produce biomechanical force to move teeth. The use orthodontic wire within the mouth interacts with saliva, causing the release of nickel and chromium ions. Purpose: The study was aimed to examine the effect of immersion time in artificial saliva between special type of Australian wire and stainless steel on the release of nickel and chromium ions. Methods: Thirty special type Australian wires and 30 stainless steel wires were used in this study, each of which weighed 0.12 grams. The wires were immersed for 1, 7, 28, 35, 42, and 49 days in artificial saliva with a normal pH. The release of ions in saliva was examined using Atomic Absorption spectrophotometry. Results: The result indicated that the release of nickel ions on special type of Australian wire was larger than that on stainless steel wire (p<0.005), there were differences in the release of the amount of nickel ions on special type of Australia in different immersion time, and there was a correlation between the types of wire and immersion time. Nickel ions released from the special type of Australian wire detected on the 7th day of immersion and reached its peak on the 35th day, while from stainless steel wire were detected on the 49th day of immersion. The released of chromium ions from the special type of Australian wire and stainless steel wire were not detected until the 49th day of immersion. Conclusion: The release of nickel ions were highest on the 35th day of immersion in special type of Australian wire and they were detected on the 49th day in stainless steel wire. The release of chromium ions were not detected until 49th day of immersion in special type of Australian and stainless steel wire.Latar belakang: Perawatan ortodonti cekat memerlukan beberapa macam kawat untuk menghasilkan kekuatan biomekanika yang sesuai dalam menggerakkan gigi. Pemakaian kawat ortodonti di dalam mulut dapat bereaksi dengan saliva sehingga menyebabkan terjadinya pelepasan ion nikel dan kromium. Tujuan: Penelitian ini bertujuan untuk meneliti pengaruh waktu perendaman dalam saliva buatan terhadap pelepasan ion nikel dan kromium antara kawat Australia tipe spesial dengan kawat stainless steel. Metode: Penelitian ini menggunakan 30 buah kawat Australia tipe spesial dan 30 buah kawat stainless steel dengan berat tiap kawat 0,12 gram. Kawat direndam selama 1, 7, 28, 35, 42 dan 49 hari dalam saliva buatan pH normal. Pemeriksaan pelepasan ion pada saliva menggunakan spektrofotometri serapan Atom. Hasil: Pelepasan ion nikel pada kawat Australia tipe spesial lebih besar dibandingkan dengan kawat stainless steel, terdapat perbedaan pelepasan jumlah ion nikel pada kawat Australia tipe spesial antara waktu perendaman dan terdapat interaksi antara jenis kawat dengan waktu perendaman. Ion nikel yang terlepas pada kawat Australia tipe spesial mulai terdeteksi pada hari ke-7 perendaman dan mencapai jumlah tertinggi pada hari ke-35 sedangkan pada kawat stainless steel mulai terdeteksi pada perendaman hari ke-49. Pelepasan ion kromium pada kawat Australia tipe spesial dan kawat stainless steel tidak terdeteksi sampai perendaman hari ke-49. Simpulan: Pelepasan ion nikel pada kawat Australia tipe special terdeteksi paling tinggi pada lama perendaman hari ke tiga puluh lima, kawat stainless steel terdeteksi pada lama perendaman hari ke empat puluh sembilan. Pelepasan ion kromium pada kawat Australia tipe special dan stainless steel tidak terdeteksi sampai lama perendaman hari ke empat puluh sembilan.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 77 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Muhammadiyah University of Yogyakarta
  • Universidade de Santiago de Compostela
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sri SuparwitriUniversitas Gadjah Mada4
Niswati Fathmah RosyidaUniversitas Gadjah Mada3
Ika Dewi AnaUniversitas Gadjah Mada2
Siti SunarintyasUniversitas Gadjah Mada1
Andi TriawanUniversitas Gadjah Mada1
Marsetyawan H. N. E. SoesatyoUniversitas Gadjah Mada1
SismindariUniversitas Gadjah Mada1
Widya AsmaraUniversitas Gadjah Mada1
Tita Ratya UtariMuhammadiyah University of Yogyakarta1
Yenni HanimastutiUniversitas Gadjah Mada1
Darmawan SutantyoUniversitas Gadjah Mada1
Setiarini WidiarsantiUniversitas Gadjah Mada1
Dewi AgustinaUniversitas Gadjah Mada1
Sofia Mubarika HaryanaUniversitas Gadjah Mada1
Bramita Beta ArnandaUniversitas Gadjah Mada1
Dyah KaruniaUniversitas Gadjah Mada1
Elfira MaharaniUniversitas Gadjah Mada1
Cendrawasih Andusyana FarmasyantiUniversitas Gadjah Mada1
Annisa Nurul FikriUniversitas Gadjah Mada1
Diatri Nari RatihUniversitas Gadjah Mada1
Ananto Ali AlhasyimiUniversitas Gadjah Mada1
Francisco José Vázquez-SantosUniversidade de Santiago de Compostela1
Ryza YashaUniversitas Gadjah Mada1
Sarah Fitria RomadhoniUniversitas Gadjah Mada1
Hasna Syifa YunivaUniversitas Gadjah Mada1
Teguh AriyantoUniversitas Gadjah Mada1
Akhmad Kharis NugrohoUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Pelepasan ion nikel dan kromium kawat Australia dan stainless steel dalam saliva buatan (The release of nickel and chromium ions from Australian wire and stainless steel in artificial saliva)</dc:title>
	<dc:creator>Rasyid, Nolista Indah</dc:creator>
	<dc:creator>Pudyani, Pinandi Sri</dc:creator>
	<dc:creator>Heryumani, JCP</dc:creator>
	<dc:subject xml:lang="en-US">Australian wire</dc:subject>
	<dc:subject xml:lang="en-US">stainless steel</dc:subject>
	<dc:subject xml:lang="en-US">immersion time</dc:subject>
	<dc:subject xml:lang="en-US">nickel ion</dc:subject>
	<dc:subject xml:lang="en-US">chromium ion</dc:subject>
	<dc:subject xml:lang="en-US">Kawat Australia tipe spesial</dc:subject>
	<dc:subject xml:lang="en-US">lama perendaman</dc:subject>
	<dc:subject xml:lang="en-US">ion nickel</dc:subject>
	<dc:subject xml:lang="en-US">ion chromium</dc:subject>
	<dc:description xml:lang="en-US">Background: Fixed orthodontic treatment needs several types of wire to produce biomechanical force to move teeth. The use orthodontic wire within the mouth interacts with saliva, causing the release of nickel and chromium ions. Purpose: The study was aimed to examine the effect of immersion time in artificial saliva between special type of Australian wire and stainless steel on the release of nickel and chromium ions. Methods: Thirty special type Australian wires and 30 stainless steel wires were used in this study, each of which weighed 0.12 grams. The wires were immersed for 1, 7, 28, 35, 42, and 49 days in artificial saliva with a normal pH. The release of ions in saliva was examined using Atomic Absorption spectrophotometry. Results: The result indicated that the release of nickel ions on special type of Australian wire was larger than that on stainless steel wire (p&amp;lt;0.005), there were differences in the release of the amount of nickel ions on special type of Australia in different immersion time, and there was a correlation between the types of wire and immersion time. Nickel ions released from the special type of Australian wire detected on the 7th day of immersion and reached its peak on the 35th day, while from stainless steel wire were detected on the 49th day of immersion. The released of chromium ions from the special type of Australian wire and stainless steel wire were not detected until the 49th day of immersion. Conclusion: The release of nickel ions were highest on the 35th day of immersion in special type of Australian wire and they were detected on the 49th day in stainless steel wire. The release of chromium ions were not detected until 49th day of immersion in special type of Australian and stainless steel wire.Latar belakang: Perawatan ortodonti cekat memerlukan beberapa macam kawat untuk menghasilkan kekuatan biomekanika yang sesuai dalam menggerakkan gigi. Pemakaian kawat ortodonti di dalam mulut dapat bereaksi dengan saliva sehingga menyebabkan terjadinya pelepasan ion nikel dan kromium. Tujuan: Penelitian ini bertujuan untuk meneliti pengaruh waktu perendaman dalam saliva buatan terhadap pelepasan ion nikel dan kromium antara kawat Australia tipe spesial dengan kawat stainless steel. Metode: Penelitian ini menggunakan 30 buah kawat Australia tipe spesial dan 30 buah kawat stainless steel dengan berat tiap kawat 0,12 gram. Kawat direndam selama 1, 7, 28, 35, 42 dan 49 hari dalam saliva buatan pH normal. Pemeriksaan pelepasan ion pada saliva menggunakan spektrofotometri serapan Atom. Hasil: Pelepasan ion nikel pada kawat Australia tipe spesial lebih besar dibandingkan dengan kawat stainless steel, terdapat perbedaan pelepasan jumlah ion nikel pada kawat Australia tipe spesial antara waktu perendaman dan terdapat interaksi antara jenis kawat dengan waktu perendaman. Ion nikel yang terlepas pada kawat Australia tipe spesial mulai terdeteksi pada hari ke-7 perendaman dan mencapai jumlah tertinggi pada hari ke-35 sedangkan pada kawat stainless steel mulai terdeteksi pada perendaman hari ke-49. Pelepasan ion kromium pada kawat Australia tipe spesial dan kawat stainless steel tidak terdeteksi sampai perendaman hari ke-49. Simpulan: Pelepasan ion nikel pada kawat Australia tipe special terdeteksi paling tinggi pada lama perendaman hari ke tiga puluh lima, kawat stainless steel terdeteksi pada lama perendaman hari ke empat puluh sembilan. Pelepasan ion kromium pada kawat Australia tipe special dan stainless steel tidak terdeteksi sampai lama perendaman hari ke empat puluh sembilan.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2014-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/729</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v47.i3.p168-172</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 47 No. 3 (2014): September 2014; 168-172</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/729/511</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
</oai_dc:dc>