Evaluation of seat and non-seat post preparation design using conventional and computational methods

Dental Journal (Majalah Kedokteran Gigi) · Vol. 42 No. 4 (2009) · hlm. 179–184

DOI
10.20473/j.djmkg.v42.i4.p179-184
ISSN
2442-9740, 1978-3728
Terbit
2009-12-01
Penerbit
Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa
eng

Abstrak

Background: Design of root canal preparation especially in cervical-third area of the root, is one of many factors involved in the success of post-core restoration. Seat design that is used in Prosthodontics Installation, Faculty of Dentistry, University of Padjadjaran, is in the contrary to minimal preparation design. The root fracture resistance of this design has not been proven yet. Purpose: The aim of this study was to evaluate the root fracture resistance of seat compare to non-seat design, with two different research methods: experimental laboratory and computer simulation with Finite Element Method (FEM). Method: The experimental laboratory investigation used 20 upper central incisors: 10 used seat design and 10 non-seats, with the cast posts cemented in the preparation. The specimens were tested by using Universal Testing Machine with compressive force until the root fracture. The FEM used 2D digital models: seat and non-seat design of maxillary central incisors using a finite element software. The distribution of internal stress caused by static loading 110N at 135° angle with longitudinal axis of the tooth was evaluated. Result: The results of the fracture strength test showed a significant difference (p = 0.05) between the non-seat group (852.27N ± 112.6N) and the seat group (495.78N ± 82.90N). The FEM showed a lower stress concentration in non-seat compare to seat group. This study proved that non-seat distributes stress better than seat design. Conclusion: It can be concluded that the FEM confirmed the result of the laboratory method. Stress concentration will cause fracture, therefore root fracture resistance in the non-seat design was higher than the seat design.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 82 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Padjadjaran University
  • Dr. Hasan Sadikin General Hospital
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sandro MihradiBandung Institute of Technology2
Leonardo GunawanBandung Institute of Technology2
Andi Isra MahyuddinBandung Institute of Technology1
Hari GolfiantoBandung Institute of Technology1
Satrio WicaksonoBandung Institute of Technology1
Nur Ridhwan MuharramBandung Institute of Technology1
Hermawan JudawisastraBandung Institute of Technology1
Muhammad Hamzah FarrasamulyaBandung Institute of Technology1
Andi KuswoyoBandung Institute of Technology1
Hari UtomoBandung Institute of Technology1
Syarif HidayatBandung Institute of Technology1
Jam’ah HalidBandung Institute of Technology1
Mipi Ananta KusumaBandung Institute of Technology1
Reza Widianto SudjudDr. Hasan Sadikin General Hospital1
Ike Sri RejekiPadjadjaran University1
Sri RaharnoBandung Institute of Technology1
Dadang RukantaBandung Institute of Technology1
Hari TjahjonoAfiliasi tidak diketahui1
Afdhal AfdhalAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Evaluation of seat and non-seat post preparation design using conventional and computational methods</dc:title>
	<dc:creator>Subrata, G.</dc:creator>
	<dc:creator>Hasratiningsih, Z.</dc:creator>
	<dc:creator>Kurnikasari, E.</dc:creator>
	<dc:creator>Dirgantara, T.</dc:creator>
	<dc:subject xml:lang="en-US">post preparation design</dc:subject>
	<dc:subject xml:lang="en-US">stress distribution</dc:subject>
	<dc:subject xml:lang="en-US">finite element method (FEM)</dc:subject>
	<dc:subject xml:lang="en-US">root fracture resistance</dc:subject>
	<dc:description xml:lang="en-US">Background: Design of root canal preparation especially in cervical-third area of the root, is one of many factors involved in the success of post-core restoration. Seat design that is used in Prosthodontics Installation, Faculty of Dentistry, University of Padjadjaran, is in the contrary to minimal preparation design. The root fracture resistance of this design has not been proven yet. Purpose: The aim of this study was to evaluate the root fracture resistance of seat compare to non-seat design, with two different research methods: experimental laboratory and computer simulation with Finite Element Method (FEM). Method: The experimental laboratory investigation used 20 upper central incisors: 10 used seat design and 10 non-seats, with the cast posts cemented in the preparation. The specimens were tested by using Universal Testing Machine with compressive force until the root fracture. The FEM used 2D digital models: seat and non-seat design of maxillary central incisors using a finite element software. The distribution of internal stress caused by static loading 110N at 135° angle with longitudinal axis of the tooth was evaluated. Result: The results of the fracture strength test showed a significant difference (p = 0.05) between the non-seat group (852.27N ± 112.6N) and the seat group (495.78N ± 82.90N). The FEM showed a lower stress concentration in non-seat compare to seat group. This study proved that non-seat distributes stress better than seat design. Conclusion: It can be concluded that the FEM confirmed the result of the laboratory method. Stress concentration will cause fracture, therefore root fracture resistance in the non-seat design was higher than the seat design.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2009-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/939</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v42.i4.p179-184</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 42 No. 4 (2009): December 2009; 179-184</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/939/722</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
</oai_dc:dc>