Cold curing acrylic is more porous, having more residual monomer and dimensional change. Physical property of cold curing acrylic shows to have very small dimensional change resulted from imperfect polymerization process and if dimensional change occurs, it would cause improper use of orthodontic appliance. Orthodontic acrylic base plate which is made of cold curing acrylic, in order to achieve good result, it is suggested to use hydro flask or polyclav with water temperature 45°–50°C and polyclav and pressure in 2–3 atm during polymerization process. Even though cold curing acrylic could polymerization at room temperature, the purpose to use hydro flask or polyclav is to reduce residual monomer and porosity. The purpose of the present study is to know the difference in dimensional accuracy of orthodontic acrylic at various polymerization temperature. The samples of the study were 18 acrylic base plate sized 65 í— 10 í— 25 mm classified into 3 control groups with polymerization temperature at 30° C, 40° C and 50° C. Measurement was done using caliper in order to know dimensional accuracy of orthodontic acrylic. The measurement result was tabulated and One-Way ANOVA test one was done with significant level 95%, the probability result 0,0055 was found which means there was significant difference among each control group. LSD test showed that group I polymerization at 30° C, group II polymerization at 40° C, and group III polymerization at 50°C there was significant difference. The conclusion of this study is: dimensional difference of orthodontic acrylic base plate on polymerization at group I at 30° C, group II at 40° C, and group III at 50° C water temperature and could achieve better dimensional accuracy comparing with polymerization at 50° C.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Gusti Aju Wahju ArdaniUniversitas Airlangga1
Nadiya FitriyaniUniversitas Airlangga1
Sianiwati GoenhartoUniversitas Airlangga1
Dini SetyowatiUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Various polymerization temperature on dimensional accuracy of orthodontic acrylic base plate</dc:title>
	<dc:creator>Rusdiana, Elly</dc:creator>
	<dc:subject xml:lang="en-US">cold curing acrylic</dc:subject>
	<dc:subject xml:lang="en-US">dimension</dc:subject>
	<dc:subject xml:lang="en-US">polymerization</dc:subject>
	<dc:description xml:lang="en-US">Cold curing acrylic is more porous, having more residual monomer and dimensional change. Physical property of cold curing acrylic shows to have very small dimensional change resulted from imperfect polymerization process and if dimensional change occurs, it would cause improper use of orthodontic appliance. Orthodontic acrylic base plate which is made of cold curing acrylic, in order to achieve good result, it is suggested to use hydro flask or polyclav with water temperature 45°–50°C and polyclav and pressure in 2–3 atm during polymerization process. Even though cold curing acrylic could polymerization at room temperature, the purpose to use hydro flask or polyclav is to reduce residual monomer and porosity. The purpose of the present study is to know the difference in dimensional accuracy of orthodontic acrylic at various polymerization temperature. The samples of the study were 18 acrylic base plate sized 65 í— 10 í— 25 mm classified into 3 control groups with polymerization temperature at 30° C, 40° C and 50° C. Measurement was done using caliper in order to know dimensional accuracy of orthodontic acrylic. The measurement result was tabulated and One-Way ANOVA test one was done with significant level 95%, the probability result 0,0055 was found which means there was significant difference among each control group. LSD test showed that group I polymerization at 30° C, group II polymerization at 40° C, and group III polymerization at 50°C there was significant difference. The conclusion of this study is : dimensional difference of orthodontic acrylic base plate on polymerization at group I at 30° C, group II at 40° C, and group III at 50° C water temperature and could achieve better dimensional accuracy comparing with polymerization at 50° C.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2007-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/1036</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v40.i4.p170-172</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 40 No. 4 (2007): December 2007; 170-172</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/1036/819</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2015 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
</oai_dc:dc>