Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Microleakage difference between total-etch and self-etch bonding in bulk fill packable composite restoration after carbonic acid immersion

Dental Journal (Majalah Kedokteran Gigi) · Vol. 52 No. 4 (2019) · hlm. 192–196

DOI
10.20473/j.djmkg.v52.i4.p192-196
ISSN
2442-9740, 1978-3728
Terbit
2019-12-31
Penerbit
Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa
eng

Abstrak

Background: Bulk fill packable composite that can be applied to a depth of 4mm in cavities is widely used in posterior teeth restoration. Unfortunately, this composite is subject to potential microleakage which occurs due to erosion resulting from the consumption of carbonated drinks containing carbonic acid. Nevertheless, microleakage can be reduced by bonding applications the etch technique of which is divided into two forms; self-etch bonding and total-etch bonding. Purpose: This study aims to determine the difference in microleakage between total-etch and self-etch bonding in bulk fill packable composite following carbonic acid immersion. Methods: This study constitutes experimental laboratory research utilizing 28 incisors bovine teeth which were cleaned, immersed in 0.01% NaCl, and randomly divided into four groups. The cervical area of the teeth of all groups were prepared through the creation of cylindrical shapes 2mm in diameter and 3 mm deep. Groups I and III used total-etch bonding, while groups II and IV used self-etch bonding. Groups III and IV were control groups, whereas groups I and II were treatment groups (immersed in carbonic acid) for 24 hours. Thermocycling was carried out in all groups which were subsequently immersed in 1% methylene blue for 24 hours after which the teeth were cut in a buccolingual direction using a diamond disc wheel. Microleakage was subsequently evaluated by calculating the amount of methylene blue passing between the restoration wall and cavity using a Stereomicroscope and scanning electron microscope (SEM). The data was then analyzed using Kruskal Wallis and Mann Whitney U tests. Results: There was a significant difference between the control groups and treatment groups (p<0.05). The microleakage in Group 2 was higher than that of other groups. Conclusion: The microleakage of total-etch bonding was lower than self-etch bonding in bulk fill packable composite after carbonic acid immersion.

Kata kunci

Jaringan kolaborasi para penulis

29 penulis · 79 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Royal College of Surgeons of Edinburgh
  • Bolan University of Medical and Health Sciences
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ira WidjiastutiUniversitas Airlangga3
Nirawati PribadiUniversitas Airlangga3
Gabriela Kevina AlifenUniversitas Airlangga2
Tengku Natasha Eleena binti Tengku Ahmad NoorRoyal College of Surgeons of Edinburgh2
Ketut SuarditaUniversitas Airlangga1
Febriastuti CahyaniUniversitas Airlangga1
Devi Eka JuniartiUniversitas Airlangga1
Eresha Melati Kusuma WurdaniUniversitas Airlangga1
Yovita YonasUniversitas Airlangga1
N. NormayantiUniversitas Airlangga1
Jayanti RoshaUniversitas Airlangga1
Putu Dewi Purnama Sari BudhaUniversitas Airlangga1
Moch. MudjionoUniversitas Airlangga1
Sri KunartiUniversitas Airlangga1
Dur Muhammad LashariBolan University of Medical and Health Sciences1
Nadhifa SalmaUniversitas Airlangga1
Tasya NafatilaUniversitas Airlangga1
Nisrina Qurrota AiniAfiliasi tidak diketahui1
Kun IsmiyatinUniversitas Airlangga1
Paramita Tanjung SariUniversitas Airlangga1
SukatonUniversitas Airlangga1
Fridianty AnggraeniUniversitas Airlangga1
Nadia Dwi MaharaniUniversitas Airlangga1
SukatonUniversitas Airlangga1
Yashinta RamadhintaUniversitas Airlangga1
Tiffany Josephine HidayatUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Microleakage difference between total-etch and self-etch bonding in bulk fill packable composite restoration after carbonic acid immersion</dc:title>
	<dc:creator>Saraswati, Widya</dc:creator>
	<dc:creator>Kumalasari, Dian Pramita Ayu</dc:creator>
	<dc:creator>Soetojo, Adioro</dc:creator>
	<dc:subject xml:lang="en-US">bulk fill packable composite</dc:subject>
	<dc:subject xml:lang="en-US">carbonic acid</dc:subject>
	<dc:subject xml:lang="en-US">microleakage</dc:subject>
	<dc:subject xml:lang="en-US">self-etch bonding</dc:subject>
	<dc:subject xml:lang="en-US">total-etch bonding</dc:subject>
	<dc:description xml:lang="en-US">Background: Bulk fill packable composite that can be applied to a depth of 4mm in cavities is widely used in posterior teeth restoration. Unfortunately, this composite is subject to potential microleakage which occurs due to erosion resulting from the consumption of carbonated drinks containing carbonic acid. Nevertheless, microleakage can be reduced by bonding applications the etch technique of which is divided into two forms; self-etch bonding and total-etch bonding. Purpose: This study aims to determine the difference in microleakage between total-etch and self-etch bonding in bulk fill packable composite following carbonic acid immersion. Methods: This study constitutes experimental laboratory research utilizing 28 incisors bovine teeth which were cleaned, immersed in 0.01% NaCl, and randomly divided into four groups. The cervical area of the teeth of all groups were prepared through the creation of cylindrical shapes 2mm in diameter and 3 mm deep. Groups I and III used total-etch bonding, while groups II and IV used self-etch bonding. Groups III and IV were control groups, whereas groups I and II were treatment groups (immersed in carbonic acid) for 24 hours. Thermocycling was carried out in all groups which were subsequently immersed in 1% methylene blue for 24 hours after which the teeth were cut in a buccolingual direction using a diamond disc wheel. Microleakage was subsequently evaluated by calculating the amount of methylene blue passing between the restoration wall and cavity using a Stereomicroscope and scanning electron microscope (SEM). The data was then analyzed using Kruskal Wallis and Mann Whitney U tests. Results: There was a significant difference between the control groups and treatment groups (p&amp;lt;0.05). The microleakage in Group 2 was higher than that of other groups. Conclusion: The microleakage of total-etch bonding was lower than self-etch bonding in bulk fill packable composite after carbonic acid immersion.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2019-12-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/16701</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v52.i4.p192-196</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 52 No. 4 (2019): December 2019; 192-196</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/16701/9728</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
</oai_dc:dc>