Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Silicone loop alternative for posterior bitewing radiography

Dental Journal (Majalah Kedokteran Gigi) · Vol. 54 No. 1 (2021) · hlm. 35–38

DOI
10.20473/j.djmkg.v54.i1.p35-38
ISSN
2442-9740, 1978-3728
Terbit
2021-02-17
Penerbit
Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en
Bahasa
eng

Abstrak

Background: Bitewing radiography is a technique that depicts the crown of the maxillary and mandibular teeth and the crest of the alveolar bone in the same receptor. The use of film holders and paper loops in bitewing techniques is very helpful in standardising radiographs, but it has some disadvantages, including the lack of efficiency and discomfort. Therefore, silicone has been widely used in the medical field as a replacement for paper loops. Purpose: This study was conducted to describe the compatibility of the silicone material as an alternative for bitewing radiography. Methods: This research is experimental and a one-shot case study. It used the Mann–Whitney (P 0.05). Conclusion: Silicone loops can be an alternative tool for bitewing radiography because they result in optimal image quality.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sriwijaya University
  • University of Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Elza Ibrahim AuerkariUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://e-journal.unair.ac.id/MKG/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Silicone loop alternative for posterior bitewing radiography</dc:title>
	<dc:creator>Prativi, Shinta Amini</dc:creator>
	<dc:creator>Chairani, Shanty</dc:creator>
	<dc:creator>Hestingsih, Tyas</dc:creator>
	<dc:subject xml:lang="en-US">bitewing radiographs</dc:subject>
	<dc:subject xml:lang="en-US">quality images</dc:subject>
	<dc:subject xml:lang="en-US">silicone</dc:subject>
	<dc:description xml:lang="en-US">Background: Bitewing radiography is a technique that depicts the crown of the maxillary and mandibular teeth and the crest of the alveolar bone in the same receptor. The use of film holders and paper loops in bitewing techniques is very helpful in standardising radiographs, but it has some disadvantages, including the lack of efficiency and discomfort. Therefore, silicone has been widely used in the medical field as a replacement for paper loops. Purpose: This study was conducted to describe the compatibility of the silicone material as an alternative for bitewing radiography. Methods: This research is experimental and a one-shot case study. It used the Mann–Whitney (P &amp;lt; 0.05) test for statistical analysis to compare the results of the radiographs using silicone loops and paper loops and to analyse the quality of each radiograph: object coverage, density, contrast, sharpness, geometry, and overlapping. Results: The images where silicone loops were used show adequate results in six radiograph quality assessments. There was no significant difference between the radiographs that were obtained using the silicon loop and the paper loop (p &amp;gt; 0.05). Conclusion: Silicone loops can be an alternative tool for bitewing radiography because they result in optimal image quality. </dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en</dc:publisher>
	<dc:date>2021-02-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/MKG/article/view/23831</dc:identifier>
	<dc:identifier>10.20473/j.djmkg.v54.i1.p35-38</dc:identifier>
	<dc:source xml:lang="en-US">Dental Journal (Majalah Kedokteran Gigi); Vol. 54 No. 1 (2021): March 2021; 35-38</dc:source>
	<dc:source>2442-9740</dc:source>
	<dc:source>1978-3728</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/MKG/article/view/23831/13506</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Dental Journal (Majalah Kedokteran Gigi)</dc:rights>
</oai_dc:dc>